TRI6 TRACOPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
DC/DC Converter TRI 6 Series, 6 Watt
- Reinforced I/O-isolation 5000 VAC rated for 1000 VAC working voltage
- Ultra-high isolation peak voltage 9000 VDC (1s)
- Common Mode Transient Immunity (dv/dt) 15 kV/µs
- Operating temperature range -40 to +85°C
- Low no-load power consumption 120 – 240 mW
- Internal EN 55032 class A filter
- High efficiency up to 89%
- 2:1 input voltage range: 9-18, 18-36, 36-75 VDC
- Protection against overload, overvoltage and short circuit
- 3-year product warranty IEC 62368-1UL 62368-1 The new TRI 6 is a high isolation, regulated 6 Watt DC/DC converter series which comes in a compact DIP-24 package. The core characteristic of the TRI 6 series is a sophisticated reinforced isolation system which is able to with- stand high test voltages (9000 VDC for 1s and 5000 VAC for 60s) and working voltages (1000 VACrms). Complementing this isolation characteristic is a high Common Mode Transient Immunity of 15 kV/µs. The new design allows to fully integrate an EN 55032 class A filter and greatly reduces the no-load power consumption. High efficiencies up to 89% allow safe operation from –40°C to +85°C without derating. All models have a wide 2:1 input voltage range and precisely regulated, isolated output voltages. With the latest IT safety certifica- tions (IEC/EN/UL 62368-1) the TRI 6 series is the perfect choice for many de- manding applications in the industrial, transportation and instrumentation sec- tors. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRI 6-1211 9 - 18 VDC (12 VDC nom.)
5 VDC 1'200 mA 83 %
TRI 6-1212 12 VDC 500 mA 86 % TRI 6-1213 15 VDC 400 mA 86 % TRI 6-1215 24 VDC 250 mA 86 % TRI 6-1222 +12 VDC 250 mA –12 VDC 250 mA 87 % TRI 6-1223 +15 VDC 200 mA –15 VDC 200 mA 87 % TRI 6-2411 18 - 36 VDC (24 VDC nom.) TRI 6-2412 12 VDC 500 mA 86 % TRI 6-2413 15 VDC 400 mA 87 % TRI 6-2415 24 VDC 250 mA 85 % TRI 6-2422 +12 VDC 250 mA –12 VDC 250 mA 86 % TRI 6-2423 +15 VDC 200 mA –15 VDC 200 mA 87 % TRI 6-4811 36 - 75 VDC (48 VDC nom.) TRI 6-4812 12 VDC 500 mA 86 % TRI 6-4813 15 VDC 400 mA 89 % TRI 6-4815 24 VDC 250 mA 86 % TRI 6-4822 +12 VDC 250 mA –12 VDC 250 mA 87 % TRI 6-4823 +15 VDC 200 mA –15 VDC 200 mA 88 % www.tracopower.com November 30, 2022 Page 1 / 4
Input Current - At no load 12 Vin models: 10 mA typ. 24 Vin models: 8 mA typ. 48 Vin models: 5 mA typ. - At full load 12 Vin models: 583 mA typ. 24 Vin models: 291 mA typ. 48 Vin models: 144 mA typ. Surge Voltage 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 12 Vin models: 8 VDC typ. 24 Vin models: 16 VDC typ. 48 Vin models: 34 VDC typ. Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Input Specifications Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance (symmetrical load) dual output models: 2% max. - Cross Regulation (25% / 100% asym. load) dual output models: 5% max. Ripple and Noise - 20 MHz Bandwidth 70 mVp-p max. (w/ 1 µF MLCC) Capacitive Load - single output 5 Vout models: 1'500 µF max. 12 Vout models: 260 µF max. 15 Vout models: 210 µF max. 24 Vout models: 75 µF max. - dual output 12 / -12 Vout models: 150 / 150 µF max. 15 / -15 Vout models: 110 / 110 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Start-up Time 30 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 150% typ. of Iout max. Transient Response - Response Deviation 5% max. (75% to 100% Load Step) - Response Time 300 µs typ. (75% to 100% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/tri6 Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications TRI 6 Series, 6 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4
EMI Emissions - Conducted Emissions EN 55032 class A (internal filter) EN 55032 class B (with external filter) FCC Part 15 class A (internal filter) - Radiated Emissions EN 55032 class A (with external filter) External filter proposal: www.tracopower.com/overview/tri6 EMS Immunity EN 55024 (IT Equipment) - Electrostatic Discharge Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A Ext. input component: 12 Vin models: KY 560 µF / 50 V
24 Vin models: KY 470 µF / 50 V
48 Vin models: KY 330 µF / 100 V
- Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +95°C - Case Temperature +105°C max. - Storage Temperature –50°C to +125°C Power Derating - High Temperature 5 %/K above 85°C See application note: www.tracopower.com/overview/tri6 Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 330 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 1'000 VAC Isolation Test Voltage - Input to Output, 60 s 5'000 VAC - Input to Output, 1 s 9'000 VDC Isolation Resistance - Input to Output, 500 VDC 10'000 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 40 pF max. Common Mode Transient Immunity 15 kV/µs min. Reliability - Calculated MTBF 4'612'000 h (MIL-HDBK-217F, ground benign) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Housing Material Plastic resin (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Copper Alloy (C6801) Pin Foundation Plating Nickel (2 - 4 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Footprint Type DIP24 Soldering Profile Wave Soldering 260°C / 10 s max. Weight 15.5 g General Specifications TRI 6 Series, 6 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4
Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tri6 Outline Dimensions TRI 6 Series, 6 Watt Dimensions in mm (inch) Tolerances: X.X ±0.5 (X.XX ±0.02) X.XX ±0.25 (X.XXX ±0.01) 20.32 (0.800) Ø 0.60 (0.024) 2.54 (0.100) 5.08 (0.200) 2.0 (0.08) 31.8 (1.25) BOTTOM VIEW 1 11 12 24 23 15 13 15.22 (0.599) 2.54 (0.100) 3.80 (0.15) 12.0 (0.47) 20.3 (0.80) Pinout Pin Single Output Dual Output 1 +Vin (Vcc) +Vin (Vcc)
11 No pin Common
12 –Vout No pin 13 +Vout –Vout
15 No pin +Vout
23 –Vin (GND) –Vin (GND) 24 –Vin (GND) –Vin (GND) © Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4