Features
/circle6 Universal Input Range 80~264VAC /circle6 Meets EN55011 Class B and CISPR/FCC Class B /circle6 Continuous Short Circuit Protection /circle6 Over Voltage Protection /circle6 No Load Input Power Consumption<150mW /circle6 Meets CoC Tier 2 and DOE Level VI /circle6 Meets IEC/EN 60335-1 /circle6 IEC/EN/UL 60601-1 2 MOPP Approval /circle6 IEC/EN 60601-1-11 for TR160MB /circle6 Class I (TR160MA), Class II (TR160MB) /circle6 Operating Altitude 5000m /circle6 IP22 MODEL NUMBER OUTPUT VOLTAGE OUTPUT CURRENT RIPPLE & NOISE NOTE1 VOLTAGE ACCURACY NOTE1 LINE REGULATION NOTE3 LOAD REGULATION NOTE4 %EFF. (Typ.) NOTE5 TR160MA120 12 V 12.5A 1% ±2% ±1% ±4% 91% TR160MA240 24 V 6.66 A 1% ±2% ±1% ±4% 92% TR160MA360 36 V 4.44 A 1% ±2% ±1% ±4% 92% TR160MA480 48 V 3.33A 1% ±2% ±1% ±4% 93% TR160MB120 12 V 12.5A 1% ±2% ±1% ±4% 91% TR160MB240 24 V 6.66 A 1% ±2% ±1% ±4% 92% TR160MB360 36 V 4.44 A 1% ±2% ±1% ±4% 92% TR160MB480 48 V 3.33A 1% ±2% ±1% ±4% 93% Note: 2 . Voltage accuracy is set at 60% full load. 3. Line regulation is measured from 100Vac to 240Vac with full load. 4. Load regulation measured from 60% to 100% full load and from 60% to 20% load (60% +/- 40% full load). 5. Typical efficiency at 230 VAC and 75% full load at 25°C. PART NUMBER Series Output Voltage DC Plug Type OVP DC Cable Length and Type TR160MX XXX -XX X XX X=A or B 120: 12VDC E: with OVP 47 1: 95 0mm with Ferrite Core A: Class I 240: 24VDC 12: 1220mm with Ferrite Core B: Class II 360: 36VDC 13:1800mm with Ferrite Core 480: 48VDC *UL2464 Cable for All Models 12V: Output Cable Length ≦ 950mm, DIN Power Plug 24V: Output Cable Length ≦ 1220mm, DC Jack 36V & 48V: Output Cable Length ≦ 1800mm, DC Jack Part Number Example: TR160MA480-02E13, 160W, Class I, 48VDC Output, Cable Length 1800mm
www.cincon.com 2 REVISION: V11 TR160M Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, full load at 25°C unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input Voltage All 80 264 Vac Operating Temperature See Derating Curve All -20 70 °C Storage Temperature All -40 85 °C Input/Output Isolation Voltage 1 minute All 4000 Vac Operating Altitude All 5000 m INPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Operating Voltage Range All 100 240 Vac Input Frequency Range All 47 60 Hz Maximum Input Current 100% Load, Vin=100Vac All 2.0 A Leakage Current (Earth) All 300 uA Leakage Current (Tounch) All 100 uA Under Voltage Protection All 60 66 70 V OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Output Voltage Set Point Vin=Nominal Vin, Io=60% Load, Tc=25℃. TR160MA/B120 11.76 12 12.24 Vdc TR160MA/B240 23.52 24 24.48 TR160MA/B360 35.28 36 36.72 TR160MA/B480 47.04 48 48.96 Operating Output Current Range TR160MA/B120 12.5 A TR160MA/B240 6.66 TR160MA/B360 4.44 TR160MA/B480 3.33 Holdup Time Vin=115Vac All 25 ms Output Voltage Regulation Load Regulation 40% Load to Full Load All ±4.0 % Line Regulation Vin=High Line to Low Line All ±1.0 % Over Voltage Protection Latch Off (AC Recycle to Reset) TR160MA/B120 13.5 Vdc TR160MA/B240 30 TR160MA/B360 42 TR160MA/B480 56 Over Current Protection Auto Recovery All 110 120 130 % Short Circuit Protection Auto Recovery All Output Ripple and Noise 1. Add a 0.1uF Ceramic Capacitor and a 10uF Aluminum Electrolytic Capacitor to Output. 2. Oscilloscope is 20MHz Band Width. 3. Ambient Temperature=25℃ TR160MA/B120 120 mV TR160MA/B240 240 TR160MA/B360 360 TR160MA/B480 480 Load Capacitance 1. Ambient Temperature=25℃ 2. Input Voltage is 115VAC and 230VAC 3. Output is max. Load TR160MA/B120 122500 uF TR160MA/B240 6600 TR160MA/B360 4330 TR160MA/B480 3240 Efficiency Output is Rated Load Ambient Temperature=25℃ @ Input Voltage is 230VAC TR160MA/B120 91 % TR160MA/B240 92 TR160MA/B360 92 TR160MA/B480 93
www.cincon.com 3 REVISION: V11 TR160M Series ISOLATION CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Input to Output 1 minute (without Dielectric Breakdown) All 4400 Vac Input to Earth(Ground) 1 minute (without Dielectric Breakdown) All 1700 Vac Output to Earth(Ground) 1 minute (without Dielectric Breakdown) All 1700 Vac Isolation Resistance Input to Output All 100 MΩ FEATURE CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units Switching Frequency All 115 KHz GENERAL SPECIFICATIONS PARAMETER NOTES and CONDITIONS Device Min. Typ. Max. Units MTBF Io=100%; Ta=25℃ per MIL-HDBK-217F All 370 K hours Humidity Nom-condensing All 93 % RH Shock Meets MIL-STD-810F Table 516.5,TABLE 516.5-1 10ms, each axis 3 times(+-X、Y、 Z axis) All 75 g Vibration Meets MIL-STD-810F Table 514.5C-VIII, 15~2000Hz, X、Y、Z axis, 1 hr(each axis),. total 3 hrs. All 4 g Weight All 575 grams Dimension All 5.906x2.756x1.497 Inches (150.00x70.00x38.00 mm) Safety Class I, Class II, IEC60601-1, EN60601-1-11, EN60601-1, ANSI/AAMI ES60601-1 IEC/EN 60601-1-11 for TR160MB Ed 3.1 EMC Emission EN55011 Class B, EN61000-3-2:2014, EN6100-3-3:2013, FCC CFR47 Part 15 Ed 4.0 Conducted Disturbance EN55011, FCC CFR47 Part 15 Class B Radiated Disturbance EN55011, FCC CFR47 Part 15 Class B Harmonic Current Emissions EN 61000-3-2:2014 Class A, D Voltage Fluctuations & Flicker EN 61000-3-3:2013 Criterion A EMC Immunity EN60601-1-2:2015, IEC61000-4-2,3,4,5,6,8,11 Electrostatic Discharge (ESD) IEC 61000-4-2:2008 Air Discharge: ±16kV Contact Discharge: ±4kV Criterion A Radio-Frequency, Continuous Radiated Disturbance IEC 61000-4-3:2010 Criterion A Surge IEC61000-4-5:2014, L-N: ±0.5kV, ±1kV, ±2kV L-E(Ground): ±0.5kV, ±1kV, ±2kV Criterion A Conducted Disturbances, Induced by RF Fields IEC 61000-4-6:2013 Criterion A Power Frequency Magnetic Field IEC 61000-4-8:2009 Criterion A Voltage Dips IEC 61000-4-11:2004, Dips:30% reduction, Dips: >95% reduction, Criteria A Criterion A Voltage Interruptions IEC 61000-4-11:2004, >95% Reduction Criterion B
www.cincon.com 4 REVISION: V11 TR160M Series CHARACTERISTIC CURVE Power Derating Curve Performance Data 20% 40% 60% 80% 100% 120% -20 -10 0 10 20 30 40 50 60 70 Rated Load (%) Ambient Temperature ( ℃) TR160M Derating Curve
20 LFM (Natural Convection)
20% 40% 60% 80% 100% 120% 80 100 120 140 160 180 200 220 240 260 Rated Load (%) Input Voltage (Vac) TR160M Input Voltage Derating Curve 60% 65% 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficincy (%) Current Load (%) TR160M120 (Eff Vs Io) 115V 230V 60% 65% 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficincy (%) Current Load (%) TR160M240 (Eff Vs Io) 115V 230V 60% 65% 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficincy (%) Current Load (%) TR160M360 (Eff Vs Io) 115V 230V 60% 65% 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Efficincy (%) Current Load (%) TR160MS480 (Eff Vs Io) 115V 230V
5 REVISION: V11
4Pin Power Plug Assembly Type Pin1,3:- Pin2,4:+ Shell:NC 16AWG/950mm 5.906[150.00] P2 P4 P1 P3 37.402[950.00]±1.969[50.00] UNIT:inches[mm] Millimeters:X.XX±0.5 Tolerance:Inches:X.XXX±0.02 All Dimensions are in inches[mm] LED DC Plug :Straight(ψ5.5/ψ2.5) L12mm DC Plug type: V+ ─●)─ V- 16AWG/1800mm 1.496[38.00] 5.906[150.00] 2.756[70.00] LED IEC320/C8 Din Power Plug DC Jack IEC320/C8 IEC320/C14 IEC320/C14 * For Output Voltage 12Vdc model, it must select Din Power Plug or equivalent * For Output Voltage 24Vdc to 48Vdc models, it’s able to select Din Power Plug, DC Jack or equivalent.