Technical content
Features
- Occupies very small panel space
- May be mounted singly, in continuous rows or in groups.
- Available with screw terminal molded socket.
- 4 SPDT contacts.
- Magnetic blowout device option increases DC current carrying ability DC operation, the addition of the device will normally double the contact life, due to reduced arcing. GP/ML Contact Data @ 25°C Arrangements: 4 Form C (4PDT) Material: Siver plated. Ratings: See chart. Expected Life: Mechanical: 100 million operations. Electrical: See chart and graph. Contact Ratings and Expected Life Power Factor Number of Current or Electrical Voltage (Amps) Time Constant Operations Remarks 540 VAC 3 COS Ø = 0.5 15,000 2 contacts in series
380 VAC 15 Resistive 10,000 2 contacts in parallel
380 VAC 10 Resistive 200,000
380 VAC 3 x 3.3 COS Ø = 0.8 200,000 3hp motor
220 VAC 20 Resistive 20,000 2 contacts in parallel
220 VAC 15 COS Ø = 0.5 20,000 2 contacts in parallel
220 VAC 10 Resistive 400,000
220 VAC 3 x 6 COS Ø = 0.8 200,000 3hp motor
220 VAC 5 1,500,000 Filament lamps
220 VAC 5 Resistive 3,000,000
220 VAC 2.5 COS Ø = 0.25 2,000,000
220 VAC 2 Resistive 15,000,000
220 VAC 1.25 Resistive 30,000,000 120 VDC 1.5 Resistive 20,000,000 with blow-out device
48 VDC 10 Resistive 1,000,000
NOTE: Seismic & radiation tested EGP , EML and ETR models are available. Consult factory for detailed information.
reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Coil Data Voltage: 24, 120 & 220VAC, 60 Hz. Add series resistor for 380-440VDC; 12, 24, 48, 125 & 250VDC. Duty Cycle: Continuous. Nominal Coil Power: 6VA for AC coils; 6W for DC coils. There is no surge current during operation. Initial Dielectric Strength Between non-connected terminals: 2,000V rms, 60 Hz. Between non-connected terminals & relay yoke: 2,000V rms, 60 Hz. Initial Insulation Resistance Between non-connected terminals: 109 ohms at 500VDC. Between non-connected terminals & relay yoke: 109 ohms at 500VDC. Coil Operating Voltage DC AC, 50/60Hz Nominal Coil Voltage 12 24 48 125 250 24 120 220 Minimum Pick-up Voltage at 20°C 9 18 36 94 187 19 92 175 Minimum Pick-up Voltage at 40°C 9.5 19 38 100 200 20 102 188 Maximum voltage for continuous use 13.5 27 53 143 275 27 137 245 For 380VAC – Use 6800 ohms 4 watt resistor in series with 220VAC relay. For 440VAC – Use 8200 ohms 6 watt resistor in series with 220VAC relay. Drop-out voltage is between 10% and 40% of the nomninal voltages for both DC and AC (For example: in a 120 VAC unit, drop-out will occur between 12 and 48 volts.) DC relays will function with unfiltered DC from a full-wave bridge rectifier. Operate Data @ 20°C Operate Time at Rated Voltage: Between energizing and opening of normally closed contacts, less than 18 milliseconds on AC and less than 15 milliseconds on DC. Release Time: Between energizing and closing of normally open contacts, less than 35 milliseconds on AC and less than 30 milliseconds on DC. Between de-energizing and opening of normally open contacts, less than 70 milliseconds on AC and less than 8 milliseconds on DC. Between de-energizing and closing of normally closed contacts, less than 85 milliseconds on AC and less than 25 milliseconds on DC. Environmenal Data Operating Temperature Range: 0°C to +60°C. Vibration: Single axis fragility curve data are available on request at frequencies from 5 Hz. to 33 Hz. Shock: The relay, when kept energized by means of one of its own contact sets, will withstand 40g shock load when operating on DC, and 150g shock load on AC. Mechanical Data Mounting Terminals: 16 flat base pins. Screw terminal sockets are available. Wire Connection: The 16 flat pins are arranged in four symmetrical rows of four pins; the pitch in both directions being .394”. Connection may be made to the relay by soldering. Sockets are available with screw terminals. The internal wiring of the relay is also symmetrical as shown in the adjacent figure, allowing the relay to be inserted into the socket in either of two positions. Terminals B2 and B3 are provided as extra connections for special applications. Weight: 10.9 oz. (308g) approximately. Outline Dimensions Wiring Diagrams (Bottom Views)
Ordering Information
Typical Part No. ➤ GP I N 1. Basic Series: GP = Non-latching Control Relay ML = Magnetic Latching Control Relay 2. Coil Voltage: A = 12VDC G = 24VAC, 60 Hz. B = 24VDC I = 120VAC, 60 Hz. C = 48VDC J = 220VAC, 60 Hz. D = 125VDC F = 250VDC 3. Options: N = Magnetic Blow-out Device Q = Light to indicate coil energization (GP only. 120VAC, 125VDC, 220VAC and 250VDC voltages only.) R = Internal diode to suppress coil de-energization transient. (GP only. When used on DC unit, relay release time increases to s ame value as AC unit). Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. GPD GPDN
reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. TR series
10 Amp Control Relay – Timing Version
Couples an advanced electromechanical design with a field-proven solid- state timing network, an adaptation of the circuit used in the AGASTAT premium grade SSC Timer. This unique circuit also eliminates the need for supplementary temperature-compensation components, affording unusual stability over a realistically broad operating temperature range. It also provides transient protection and protection against premature switching of the output contacts due to power interruption during timing. TR Features
- 8 timing ranges.
- 4 SPDT contacts.
- Magnetic blowout device option increases DC current carrying ability DC operation, the addition of the device will normally double the contact life, due to reduced arcing. Contact Data @ 25°C Arrangements: 4 Form C (4PDT) Nominal Rating: 10A @ 120VAC. Contact Pressure: Between movable and normally closed contacts: 30 g, typical. Between movable and normally open contacts: 100 g, typical. Expected Life: Mechanical: 100 million operations. Electrical: See load/life graph. Load Life Curve Timing Specifications Operating Mode: On-Delay (Delay on energization). Timing Adjustment: Internal fized or internal potentiometer. Timing Ranges: .15 to 3 sec. 4 to 120 sec. .55 to 15 sec. 10 to 300 sec. 1 to 30 sec. 1 to 30 min. 2 to 60 sec. 2 to 60 min. Accuracy: Repeat: ±2% as fixed temerature and voltage. Overall: ±5% over combined rated extremes of temerature and voltage. Reset Time: 75ms. Coil Data Voltage: 120VAC, 50-60 Hz.; 24 & 125VDC. Initial Dielectric Strength Between terminals and case and between mutually-isolated contacts: 2,000VAC. Initial Insulation Resistance Between non-connected terminals: 109 ohms at 500VDC. Between non-connected terminals & relay yoke: 109 ohms at 500VDC. Environmenal Data Operating Temperature Range: 0°C to +50°C. Mechanical Data Mounting Terminals: 16 flat base pins. Screw terminal sockets are available. Weight: 11 oz. (311g) approximately. Transient Protection 1,500 volt transient of less than 100 microseconds, or 1,000 volts or less.
Typical Part No. ➤ TR 1 4 B 1 A N 1. Basic Series: TR = Timing control relay 2. Operation: 1 = On-delay 3. Output: 4 = 4PDT (4 form C) 4. Operating Voltage: B = 24VDC D = 215VDC I = 120VAC, 50/60 Hz. 5. Timing Adjustment: 1 = Internal fixed. 3 = Internal potentiometer. 6. Timing Range: 7. Options: N = Magnetic blow-out device. Wiring Diagram (Bottom View) Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.. None at present. Outline Dimensions Same as GP/MR. See previous page.
reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Cat. No. CR0070 For socket: CR0095 Cat. No. CR0069 For socket: CR0067 Cat. No. CR0111 For sockets: CR0001& CR0002 *Cat. No. CR0133 For socket: CR0001 & CR0002 *Cat. No. CR0155 For socket: CR0095 * Catalog number includes strap, strap plate and necessary brackets. Cat. No. CR0190 Reduces arcing on the relay contacts when they make or break contact, either upon energizing or de-energizing, resulting in less contact degradation. Extends the life of the contact. Cat. No. CR0179 Used to remove GP , ML and TR units from mounting bases. Cat. No. CR0001 With captive clamp terminals Cat. No. CR0002 With (#6) binding head screws Cat. No. CR0095 With (#6) screw terminals Cat. No. CR0067 With (#6) screw terminals Accessories for GP/ML/TR series control relays Front connected sockets Hold down (locking) springs Heavy-duty hold down (locking) straps Magnetic blowout device Extracting handle