TPS80 TOTAL-POWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
PPS80 SWITCHING MODE 80W U CHANNEL POWER SUPPLIES KEY FEATURES *Universal input *Built-in EMI filter *Optional ±12VDC/±24VDC/±48VDC input *Optional cover
APPLICATIONS
- Telecommunications/Business machines *Computer peripherals/Medical instruments *Test & industrial equipments ELECTRICAL SPECIFICATIONS INPUT Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power----80W with 30 CFM forced air ( R e f e r n e x t p a g e ) *Hold-u n o m i n a l l i n e *Overload protection-Short circuit p r o t e c t i o n *Overvoltage n o m i n a l o u t p u t (Optional +/-0.5 % per inquiry) 80W 60W 40W 20W 40W 30W Power Derating Curve
30 CFM Forced Air Cooling
Ambient Temperature( °°°° C) Natural Convection Cooling Output Power (Watts) EMI & EMC *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2, SAFETY APPROVAL *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 (COMPLY WITH) *TUV EN60950 *Optional UL 2601 (EMI Class A) (COMPLY WITH) ENVIRONMENTAL *Operating temperature : 0 t o 50℃ambient; derate each output at 2.5% per degree from 50 ℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85 ℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25 ℃ambient conditions TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http ://www.total-power.com -1-
TPS80 SWITCHING MODE 80W U CHANNEL POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART TPS80-10 +5V ±10% Typical 16A 20A 0A ±3% ±1% 100W Typical TPS80-11 +12V ±10% Typical 6.6A 8.3A 0A ±3% ±1% 100W Typical TPS80-12 +15V ±10% Typical 5.3A 6.6A 0A ±3% ±1% 100W Typical TPS80-13 +24V ±10% Typical 3.3A 4.1A 0A ±3% ±1% 100W Typical TPS80-14 +48V ±10% Typical 1.7A 2.1A 0A ±3% ±1% 100W Typical TPS80-15 +36V ±10% Typical 2.2A 2.8A 0A ±3% ±1% 100W Typical TPS80-17 +3.3V ±10% Typical 24A 26.3A 2.4A ±5% ±1.5% 100W Typical DUAL OUTPUT MODEL SELECTION CHART +5 V ±10% Typical 8A 10A 0.8A ±5% ±1% TPS80-20 +12V Fixed 4A 5A 0.4A ±5% ±1% 100W Typical +5 V ±10% Typical 8A 10A 0.8A ±5% ±1% TPS80-21 +24V Fixed 1.7A 2.1A 0.17A ±5% ±1% 100W Typical +5 V ±10% Typical 8A 10A 0.8A ±5% ±1% TPS80-22 - 5 V Fixed 8A 10A 0.8A ±10% ±1% 100W Typical +12V ±10% Typical 3.3A 4.1A 0.33A ±5% ±1% TPS80-23 -12 V Fixed 3.3A 4.1A 0.33A ±10% ±1% 100W Typical +15 V ±10% Typical 2.7A 3.4A 0.27A ±5% ±1% TPS80-24 -15 V Fixed 2.7A 3.4A 0.27A ±10% ±1% 100W Typical +3.3V ±10% Typical 10A 12.5A 1A ±5% ±1.5% TPS80-25 +12 V Fixed 4A 5A 0.4A ±5% ±1% 100W Typical +12V ±10% Typical 4A 5A 0.4A ±5% ±1% TPS80-26 +24V Fixed 1.3A 1.6A 0.13A ±10% ±1% 100W Typical +5V ±10% Typical 8A 10.4A 0.8A ±5% ±1% TPS80-27Y +15V Fixed 3.2A 4A 0.32A ±10% ±1% 100W Typical +12.5V ±10% Typical 4.5A 5.6A 0.45A ±5% ±1% TPS80-28 +16V Fixed 1.5A 1.8A 0.15A ±10% ±1% 100W Typical +3.3V ±10% Typical 16A 20A 1.6A ±5% ±1.5% TPS80-29 +5V Fixed 6A 7.5A 0.6A ±5% ±1% 100W Typical TRIPLE OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 8A 10A 0.8A ±5% ±1% TPS80-30 +12V Fixed 5A 6.3A 0.5A ±5% ±1% - 5 V Fixed 1A 1.3A 0.1A ±10% ±1% 100W Typical + 5V ±10% Typical 8A 10A 0.8A ±5% ±1% TPS80-31 +12V Fixed 2.9A 3.6A 0.29A ±5% ±1% -12V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical + 5V ±10% Typical 8A 10A 0.8A ±5% ±1% TPS80-32 +15V Fixed 2.2A 2.8A 0.22A ±5% ±1% -15V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical + 5V ±10% Typical 10A 12.5A 1A ±5% ±1% +15V Fixed 1.6A 2A 0.16A ±5% ±1%TPS80-33 - 5 V Fixed 1A 1.3A 0.1A ±10% ±1% 100W Typical + 5V ±10% Typical 10A 12.5A 1A ±5% ±1% +15V Fixed 1.6A 2A 0.16A ±5% ±1%TPS80-34 -12V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical + 5 V ±10% Typical 7A 8.8A 0.7A ±5% ±1% +24V Fixed 1.6A 2A 0.16A ±5% ±1%TPS80-35 -12V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical + 5V ±10% Typical 7A 8.8A 0.7A ±5% ±1% +12V Fixed 3.2A 4A 0.32A ±5% ±1%TPS80-36 -12V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical + 5V ±10% Typical 7A 8.8A 0.7A ±5% ±1% +12V Fixed 2.8A 3.5A 0.28A ±5% ±1%TPS80-37 +24V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http ://www.total-power.com -2-
TPS80 SWITCHING MODE 80W U CHANNEL POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) TRIPLE OUTPUT MODEL SELECTION CHART +15V ±10% Typical 2A 2.5A 0.2A ±5% ±1% -15V Fixed 2A 2.5A 0.2A ±10% ±1%TPS80-38 +5V Fixed 4A 5A 0.4A ±10% ±1% 100W Typical +12V ±10% Typical 1.5A 1.8A 0.15A ±5% ±1% -12V Fixed 1.5A 1.8A 0.15A ±5% ±1%TPS80-39 +28V Fixed 1.6A 2A 0.16A ±10% ±1% 100W Typical QUAD OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 8A 10A 0.8A ±5% ±1% +12V Fixed 2.6A 3.3A 0.26A ±5% ±1% - 12V Fixed 0.5A 0.6A 0.05A ±10% ±1% TPS80-40 - 5 V Fixed 0.5A 0.6A 0.05A ±10% ±1% 100W Typical + 5V ±10% Typical 8A 10A 0.8A ±5% ±1% +12V Fixed 2.2A 2.8A 0.22A ±5% ±1% - 5 V Fixed 0.8A 1A 0.08A ±10% ±1% TPS80-41 - 12V Fixed 0.8A 1A 0.08A ±10% ±1% 100W Typical + 5V ±10% Typical 8A 10A 0.8A ±5% ±1% +12V Fixed 1.3A 1.6A 0.13A ±5% ±1% -15V Fixed 0.8A 1A 0.08A ±10% ±1% TPS80-42 +15V Fixed 0.8A 1A 0.08A ±10% ±1% 100W Typical + 5V ±10% Typical 4.5A 5.6A 0.45A ±5% ±1% +12V Fixed 2A 2.5A 0.2A ±5% ±1% - 12V Fixed 0.8A 1A 0.08A ±10% ±1% TPS80-43 +15V Fixed 1.6A 2A 0.16A ±10% ±1% 100W Typical + 5V ±10% Typical 4.5A 5.6A 0.45A ±5% ±1% +12V Fixed 0.8A 1A 0.08A ±5% ±1% - 12V Fixed 0.8A 1A 0.08A ±10% ±1% TPS80-44 +48V Fixed 0.8A 1A 0.08A ±10% ±1% 100W Typical + 5V ±10% Typical 8A 10.4A 0.8A ±5% ±1% +12V Fixed 0.8A 1.04A 0.08A ±5% ±1% - 12V Fixed 0.8A 1.04A 0.08A ±10% ±1% TPS80-45Y +24V Fixed 0.8A 1.04A 0.08A ±10% ±1% 100W Typical +5V ±10% Typical 8A 10.4A 0.8A ±5% ±1% +15V Fixed 0.8A 1.04A 0.08A ±5% ±1% -15V Fixed 0.8A 1.04A 0.08A ±10% ±1% TPS80-46Y +48V Fixed 0.8A 1.04A 0.08A ±10% ±1% 100W Typical +5V ±10% Typical 4A 5.2A 0.4A ±5% ±1% +12V Fixed 1.4A 1.8A 0.14A ±5% ±1% -12V Fixed 1.4A 1.8A 0.14A ±10% ±1% TPS80-47Y +36V Fixed 0.8A 1.04A 0.08A ±10% ±1% 100W Typical +5V ±10% Typical 8A 10.4A 0.8A ±5% ±1% +15V Fixed 0.8A 1.04A 0.08A ±5% ±1% -15V Fixed 0.8A 1.04A 0.08A ±10% ±1% TPS80-48Y +24V Fixed 0.8A 1.04A 0.08A ±10% ±1% 100W Typical +3.3V ±10% Typical 7A 15A 0.7A ±5% ±1.5% +5V Fixed 5A 6.2A 0.5A ±5% ±1% +12V Fixed 2.5A 6.2A 0.25A ±10% ±1% TPS80-49Y -5V Fixed 1A 3.7A 0.1A ±10% ±1% 100W Typical TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http://www.total-power.com -3-
TPS80 SWITCHING MODE 80W U CHANNEL POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load . 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal lin e, 0.1μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requ irement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. 7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover. TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http ://www.total-power.com -4-