PPS70 SWITCHING MODE 70W OPEN FRAME POWER SUPPLIES KEY FEATURES *Universal input *Built-in EMI filter *Optional ±12VDC/±24VDC/±48VDC input
APPLICATIONS
- Telecommunications/Business machines *Computer peripherals/Medical instruments *Test & industrial equipments *Lan & Hub ELECTRICAL SPECIFICATIONS INPUT Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power----70W with 30 CFM forced air ( R e f e r n e x t p a g e ) n o m i n a l l i n e *Overload protection-Short circuit protection *Overvoltage n o m i n a l o u t p u t (Optional +/-0.5 % per inquiry) 70W 50W 30W 10W 35W 25W Power Derating Curve
30 CFM Forced Air Cooling
Ambient Temperature( °°°° C) Natural Convection Cooling Output Power (Watts) EMI & EMC *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2, SAFETY APPROVAL *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 (COMPLY WITH) *TUV EN60950 *Optional UL 2601 (EMI Class A)(COMPLY WITH) ENVIRONMENTAL *Operating temperature : 0 t o 50℃ambient; derate each output at 2.5% per degree from 50 ℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85 ℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25 ℃ambient conditions POWER ADD USA, INC. TEL:978-446-7983 FAX: 978-441-1255 E-mail sales@poweraddusa.com http ://www.poweraddusa.com -1-
POWER PPS70 SWITCHING MODE 70W OPEN FRAME POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART PPS70-10 +5V ±10% Typical 14A 18.2A 0A ±3% ±1% 90W Typical PPS70-11 +12V ±10% Typical 5.9A 7.6A 0A ±3% ±1% 90W Typical PPS70-12 +15V ±10% Typical 4.7A 6.1A 0A ±3% ±1% 90W Typical PPS70-13 +24V ±10% Typical 2.9A 3.7A 0A ±3% ±1% 90W Typical PPS70-14 +48V ±10% Typical 1.46A 1.8A 0A ±3% ±1% 90W Typical PPS70-15 +36V ±10% Typical 1.95A 2.5A 0A ±3% ±1% 90W Typical PPS70-17 +3.3V ±10% Typical 21A 27.3A 2.1A ±5% ±1.5% 90W Typical DUAL OUTPUT MODEL SELECTION CHART +5 V ±10% Typical 7A 9.1A 0.7A ±5% ±1% PPS70 –20 +12V Fixed 3.5A 4.5A 0.35A ±5% ±1% 90W Typical +5 V ±10% Typical 7A 9.1A 0.7A ±5% ±1% PPS70-21 +24V Fixed 1.5A 1.9A 0.15A ±5% ±1% 90W Typical +5 V ±10% Typical 7A 9.1A 0.7A ±5% ±1% PPS70-22 - 5V Fixed 7A 9.1A 0.7A ±10% ±1% 90W Typical +12V ±10% Typical 2.9A 3.7A 0.29A ±5% ±1% PPS70-23 - 12V Fixed 2.9A 3.7A 0.29A ±10% ±1% 90W Typical +15V ±10% Typical 2.3A 2.9A 0.23A ±5% ±1% PPS70-24 - 15V Fixed 2.3A 2.9A 0.23A ±10% ±1% 90W Typical PPS70-25 +12V Fixed 3.5A 4.5A 0.35A ±5% ±1% 90W Typical +12V ±10% Typical 3.5A 4.5A 0.35A ±5% ±1% PPS70-26 +24V Fixed 1.2A 1.5A 0.12A ±5% ±1% 90W Typical +5V Fixed 7A 9.1A 0.7A ±5% ±1% PPS70-27Y +15V Fixed 2.8A 3.5A 0.28A ±5% ±1% 90W Typical +12.5V Fixed 4.5A 5.8A 0.45A ±5% ±1% PPS70-28 +16V Fixed 1A 1.3A 0.1A ±5% ±1% 90W Typical +3.3V Fixed 14A 18A 1.4A ±5% ±1.5% PPS70-29 +5V Fixed 4.7A 6.1A 0.47A ±5% ±1% 90W Typical TRIPLE OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +12V Fixed 4.4A 5.7A 0.44A ±5% ±1%PPS70-30 - 5 V Fixed 0.9A 1.1A 0.09A ±10% ±1% 90W Typical + 5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +12V Fixed 2.5A 3.2A 0.25A ±5% ±1%PPS70-31 -12V Fixed 0.4A 0.5A 0.04A ±10% ±1% 90W Typical + 5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +15V Fixed 1.9A 2.4A 0.19A ±5% ±1%PPS70-32 -15V Fixed 0.4A 0.5A 0.04A ±10% ±1% 90W Typical + 5V ±10% Typical 8.8A 11.4A 0.88A ±5% ±1% +15V Fixed 1.4A 1.8A 0.14A ±5% ±1%PPS70-33 - 5 V Fixed 0.9A 1.1A 0.09A ±10% ±1% 90W Typical + 5V ±10% Typical 8.8A 11.4A 0.88A ±5% ±1% +15V Fixed 1.4A 1.8A 0.14A ±5% ±1%PPS70-34 -12V Fixed 0.4A 0.5A 0.04A ±10% ±1% 90W Typical + 5 V ±10% Typical 6.3A 8.1A 0.63A ±5% ±1% +24V Fixed 1.4A 1.8A 0.14A ±5% ±1%PPS70-35 -12V Fixed 0.4A 0.5A 0.04A ±10% ±1% 90W Typical + 5V ±10% Typical 6.3A 8.1A 0.63A ±5% ±1% +12V Fixed 2.8A 3.6A 0.28A ±5% ±1%PPS70-36 -12V Fixed 0.4A 0.5A 0.04A ±10% ±1% 90W Typical + 5V ±10% Typical 6A 7.8A 0.6A ±5% ±1% +12V Fixed 2.5A 3.2A 0.25A ±5% ±1%PPS70-37 +24 V Fixed 0.4A 0.5A 0.04A ±10% ±1% 90W Typical POWER ADD USA, INC. TEL: 978-446-7983 FAX: 978-441-1255 E-mail: sales@poweraddusa.com http ://www.poweraddusa.com -2-
POWER PPS70 SWITCHING MODE 70W OPEN FRAME POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) TRIPLE OUTPUT MODEL SELECTION CHART +15V ±10% Typical 1.8A 2.3A 0.18A ±5% ±1% -15V Fixed 1.8A 2.3A 0.18A ±5% ±1%PPS70-38 +5V Fixed 3.3A 4.5A 0.33A ±10% ±1% 90W Typical +12V ±10% Typical 1.3A 1.7A 0.13A ±5% ±1% -12V Fixed 1.3A 1.7A 0.13A ±5% ±1%PPS70-39 +28V Fixed 1.4A 1.8A 0.14A ±10% ±1% 90W Typical QUAD OUTPUT MODEL SELECTION CHART +5V ±10% Typical 8A 10.4A 0.8A ±5% ±1% +12V Fixed 2.9A 3.8A 0.29A ±5% ±1% -12V Fixed 0.5A 0.65A 0.05A ±10% ±1% PPS70-40 -5V Fixed 0.5A 0.65A 0.05A ±10% ±1% 90W Typical +5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +12V Fixed 2.6A 3.4A 0.26A ±5% ±1% -5V Fixed 0.7A 0.9A 0.07A ±10% ±1% PPS70-41 -12V Fixed 0.7A 0.9A 0.07A ±10% ±1% 90W Typical +5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +12V Fixed 1.1A 1.4A 0.11A ±5% ±1% -15V Fixed 0.7A 0.9A 0.07A ±10% ±1% PPS70-42 +15V Fixed 0.7A 0.9A 0.07A ±10% ±1% 90W Typical +5V ±10% Typical 3.9A 5.1A 0.39A ±5% ±1% +12V Fixed 1.8A 2.3A 0.18A ±5% ±1% -12V Fixed 0.7A 0.9A 0.07A ±10% ±1% PPS70-43 +15V Fixed 1.4A 1.8A 0.14A ±10% ±1% 90W Typical +5V ±10% Typical 3.9A 5.1A 0.39A ±5% ±1% +12V Fixed 0.7A 0.9A 0.07A ±5% ±1% -12V Fixed 0.7A 0.9A 0.07A ±10% ±1% PPS70-44 +48V Fixed 0.7A 0.9A 0.07A ±10% ±1% 90W Typical +5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +12V Fixed 0.7A 0.91A 0.07A ±5% ±1% -12V Fixed 0.7A 0.91A 0.07A ±10% ±1% PPS70-45Y +24V Fixed 0.7A 0.91A 0.07A ±10% ±1% 90W Typical +5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +15V Fixed 0.7A 0.91A 0.07A ±5% ±1% -15V Fixed 0.7A 0.91A 0.07A ±10% ±1% PPS70-46Y +48V Fixed 0.7A 0.91A 0.07A ±10% ±1% 90W Typical +5V ±10% Typical 3.5A 4.5A 0.35A ±5% ±1% +12V Fixed 1.3A 1.7A 0.13A ±5% ±1% -12V Fixed 1.3A 1.7A 0.13A ±10% ±1% PPS70-47Y +36V Fixed 0.7A 0.91A 0.07A ±10% ±1% 90W Typical +5V ±10% Typical 7A 9.1A 0.7A ±5% ±1% +15V Fixed 0.7A 0.91A 0.07A ±5% ±1% -15V Fixed 0.7A 0.91A 0.07A ±10% ±1% PPS70-48Y +24V Fixed 0.7A 0.91A 0.07A ±10% ±1% 90W Typical +3.3V ±10% Typical 5A 9.1A 0.5A ±5% ±1.5% +5V Fixed 4.4A 5.7A 0.44A ±5% ±1% +12V Fixed 2.5A 5.7A 0.25A ±10% ±1% PPS70-49Y -5V Fixed 1A 2.8A 0.1A ±10% ±1% 90W Typical NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load . 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal lin e, 0.1μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requ irement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. 7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version. POWER ADD USA, INC. TEL: 978-446-7983 FAX: 978-441-1255 E-mail: sales@poweraddusa.com http ://www.poweraddusa.com -3-