Product description: TPS DC power distribution non-indicating fuses specifically designed to meet the unique needs of DC power distribution systems. Features and benefits:
- Telpower™ fuse line is the first to be specifically designed to meet the unique needs of DC power distribution systems.
- The UL Recognized ratings of 170Vdc and 100kA interrupting rating along with the fuse’s current-limiting capability make this fuse ideal for overcurrent protection on existing DC distribution systems.
- A unique blue label is used on all Telpower fuses to designate their DC capability.
- PCB mount versions available.
- Silver-plated brass ferrules.
- Glass melamine tube.
- For use with Bussmann fused disconnect switch 15800.
- Spare fuseholder: TPSFH-AS. Custom designs:
- Printed circuit board variations available. TPS Series DC power distribution non-indicating fuses Specifications Ratings:
- Volts 170Vdc
- Amps 1 - 70A
- IR 100kA Agency information:
- CE
- UL Recognized, Guide JFHR2, File E56412
- RoHS Compliant TPS-1 TPS-6 TPS-25L TPS-50 TPS-1L TPS-61L TPS-25V TPS-50L TPS-1LB TPS-10 TPS-30 TPS-50V TPS-2 TPS-10L TPS-30L TPS-60 TPS-2L TPS-15 TPS-35 TPS-60L TPS-3 TPS-15L TPS-35L TPS-70 TPS-3L TPS-20 TPS-40 TPS-70L TPS-5 TPS-20L TPS-40L TPS-70LB TPS-5L TPS-25 TPS-40V — Catalog numbers Suffix: L = PCB tab V = Vertical PCB tab LB = Bolt tag
TPS - DC power distribution non-indicating fuses Technical Data 5009 Effective March 2015 Dimensions - mm (in) TPS-(amp) 1.76 ±.02 (44.65mm ± .51) 1.59 ± .02 (40.26mm ± .51) 1.35 ± .015 (34.16mm ± .38) .500 (12.70mm) .348 (8.84mm) 0.74 (18.69mm) 1.261 ± .005 (32.03mm ± .13) .348 (8.84mm) .190 ± .005* (4.8mm ± .12) *Recommend #8 Slotted Hex Washer Head Machine Screw for mounting 0.755 (19.18mm) (22.2mm) (± .38) (14.3mm) (± .05) TPS-(amp)L — PCB tab TPS-(amp)V — vertical PCB tab TPS-(amp)LB — bolt tab
TPS - DC power distribution non-indicating fuses eaton www.eaton.com The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton’s Bussmann Business
114 Old State Road
Ellisville, MO 63021 United States www.bussmann.com © 2015 Eaton All Rights Reserved Publication No. 5009 - BU-SB15146 March 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners. 1,000 100 .01 TIME IN SECONDS 10,000 1,000 100 CURRENT IN AMPS 20 25 30 40 50 AMP RATING Time-current characteristic curves