TPS-180P TOTAL-POWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
PPS180 SWITCHING MODE 180W U CHANNEL POWER SUPPLIES KEY FEATURES *Universal input *Built-in EMI filter *Optional remote sense on main output *Optional constant current charger *Optional Power Good signal/Optional cover *Optional ±12VDC/±24VDC/±48VDC input *Optional constant current change (for single output)
APPLICATIONS
- Telecommunications/Medical machines *Computer peripherals/Business machines *Test & industrial equipments ELECTRICAL SPECIFICATIONS INPUT Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power---- 180W with 30 CFM forced air ( R e f e r n e x t p a g e ) n o m i n a l l i n e *Overload protection-Short circuit protection. *Overvoltage n o m i n a l o u t p u t (Optional +/- 0.5% per inquiry) 180W 130W 80W 30W 90W 65W Power Derating Curve
30 CFM Forced Air Cooling
Ambient Temperature( °°°° C) Natural Convection Cooling Output Power (Watts) EMI & EMC *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE,EN 61000-3-2 (Class A) (Optional) and –3; SAFETY APPROVAL *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 (COMPLY WITH) *TUV EN60950 *Optional UL 2601 (EMI Class A)(COMPLY WITH) ENVIRONMENTAL *Operating temperature : 0 t o 50℃ambient; derate each output at 2.5% per degree from 50 ℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85 ℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25 ℃ambient conditions TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail:sales@total-power.com http ://www.total-power.com -1-
PPS180 SWITCHING MODE 180W U CHANNEL POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART TPS180-10 +5V ±10% Typical 36A 43.2A 0A ±3% ±1% 210W Typical TPS180-11 +12V ±10% Typical 15A 18A 0A ±3% ±1% 210W Typical TPS180-12 +15V ±10% Typical 12A 14.4A 0A ±3% ±1% 210W Typical TPS180-13 +24V ±10% Typical 7.5A 9A 0A ±3% ±1% 210W Typical TPS180-14 +48V ±10% Typical 3.75A 4.5A 0A ±3% ±1% 210W Typical TPS180-15 +36V ±10% Typical 5 A 6A 0A ±3% ±1% 210W Typical TPS180-16 +56V ±10% Typical 3.2A 3.8A 0A ±3% ±1% 210W Typical TPS180-17 +18V ±10% Typical 10A 12A 0A ±3% ±1% 210W Typical TPS180-18 +3.3V ±10% Typical 36A 43.2A 0A ±5% ±1.5% 210W Typical DUAL OUTPUT MODEL SELECTION CHART +5 V ±10% Typical 22A 26.4A 2.2A ±5% ±1%TPS180-20 +12V Fixed 9A 10.8A 0.9A ±5% ±1% 210W Typical +5 V ±10% Typical 2 2 A 2 6 . 4 A 2 . 2 A ±5% ±1%TPS180-21 +24V Fixed 4.5A 5.4A 0.45A ±5% ±1% 210W Typical +5 V ±10% Typical 22A 26.4A 2.2A ±5% ±1%TPS180-22 - 5 V Fixed 22A 26.4A 2.2A ±5% ±1% 210W Typical +12V ±10% Typical 9A 10.8A 0.9A ±5% ±1%TPS180-23 - 12 V Fixed 9A 10.8A 0.9A ±5% ±1% 210W Typical +15 V ±10% Typical 7.2A 8.6A 0.72A ±5% ±1%TPS180-24 - 15 V Fixed 7.2A 8.6A 0.72A ±5% ±1% 210W Typical +3.3V Fixed 25A 30A 2.5A ±5% ±1.5%TPS180-25 +12 V ±10% Typical 10A 12A 1A ±5% ±1% 210W Typical + 12V ±10% Typical 10.5A 12.6A 1.05A ±5% ±1%TPS180-26 + 24V Fixed 4 A 4.8A 0.4 A ±5% ±1% 210W Typical + 10.3V ±10% Typical 8.5A 10.2A 0.85A ±5% ±1%TPS180-27 + 24V Fixed 4.8A 5.8A 0.48A ±5% ±1% 210W Typical + 5 V ±10% Typical 25A 30A 2.5A ±5% ±1%TPS180-28 + 3.3V Fixed 18A 21.6A 1.8A ±5% ±1.5% 210W Typical TRIPLE OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 22 A 26.4 A 2.2 A ±5% ±1% +12V Fixed 9 A 10.8 A 0.9 A ±5% ±1%TPS180-30 - 5 V Fixed 1.5A 1.8 A 0.15 A ±10% ±1% 210W Typical + 5V ±10% Typical 22 A 26.4 A 2.2 A ±5% ±1% +12V Fixed 7.5A 9 A 0.75 A ±5% ±1%TPS180-31 -12V Fixed 2 A 2.4 A 0.2 A ±10% ±1% 210W Typical + 5V ±10% Typical 22A 26.4A 2.2 A ±5% ±1% TPS180-32 +15V Fixed 6 A 7.2 A 0.6 A ±5% ±1% -15V Fixed 1.5A 1.8 A 0.15 A ±10% ±1% 210W Typical + 5V ±10% Typical 25A 30 A 2.5 A ±5% ±1% +15V Fixed 5.5A 6.6 A 0.55 A ±5% ±1%TPS180-33 - 5 V Fixed 3 A 3.6 A 0.3 A ±10% ±1% 210W Typical + 5V ±10% Typical 25A 30 A 2.5 A ±5% ±1% +15V Fixed 5.5A 6.6 A 0.55 A ±5% ±1%TPS180-34 -12 V Fixed 2 A 2.4 A 0.2 A ±10% ±1% 210W Typical + 5 V ±10% Typical 20A 24 A 2 A ±5% ±1% -12V Fixed 1.3A 1.6 A 0.13 A ±5% ±1%TPS180-35 +24V Fixed 4.5A 5.4 A 0.45 A ±10% ±1% 210W Typical + 5V ±10% Typical 20A 24 A 2 A ±5% ±1% +12V Fixed 8A 9.6 A 0.8 A ±5% ±1%TPS180-36 - 12V Fixed 2A 2.4 A 0.2 A ±10% ±1% 210W Typical + 5V ±10% Typical 20A 24 A 2 A ±5% ±1% +12V Fixed 7.5A 9 A 0.75 A ±5% ±1%TPS180-37 +24V Fixed 1.2A 1.4 A 0.12 A ±10% ±1% 210W Typical + 5 V ±10% Typical 10A 12 A 1 A ±5% ±1% + 24V Fixed 2.7A 3.2A 0.27 A ±5% ±1%TPS180-38 +12V Fixed 9 A 10.8 A 0.9 A ±10% ±1% 210W Typical +18V ±10% Typical 5.8A 7 A 0.58 A ±5% ±1% - 18V Fixed 5.8A 7 A 0.58 A ±5% ±1%TPS180-39 + 5 V Fixed 3A 3.6 A 0.3 A ±10% ±1% 210W Typical TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http ://www.total-power.com -2-
TPS180 SWITCHING MODE 180W U CHANNEL POWER SUPPLIES MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) QUAD OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 22A 26.4 A 2.2A ±5% ±1% +12V Fixed 7.5A 9 A 0.75A ±5% ±1% - 12V Fixed 1.2A 1.4 A 0.12A ±10% ±1% TPS180-40 - 5 V Fixed 1.2A 1.4 A 0.12A ±10% ±1% 210W Typical + 5V ±10% Typical 22A 26.4 A 2.2A ±5% ±1% +12V Fixed 6.3A 7.6 A 0.63A ±5% ±1% - 12V Fixed 2.2A 2.6 A 0.22A ±10% ±1% TPS180-41 - 5 V Fixed 2.2A 2.6 A 0.22A ±10% ±1% 210W Typical + 5V ±10% Typical 22A 26.4 A 2.2A ±5% ±1% +12V Fixed 4.5A 5.4 A 0.45A ±5% ±1% - 15V Fixed 2.2A 2.6 A 0.22A ±10% ±1% TPS180-42 +15V Fixed 2.2A 2.6 A 0.22A ±10% ±1% 210W Typical + 5V ±10% Typical 13.5A 16.2A 1.35A ±5% ±1% +12V Fixed 5.2A 6.2A 0.52A ±5% ±1% - 12V Fixed 2.2A 2.6A 0.22A ±10% ±1% TPS180-43 - 15V Fixed 4.5A 5.4A 0.45A ±10% ±1% 210W Typical + 5V ±10% Typical 13A 15.6A 1.3A ±5% ±1% +12V Fixed 3 A 3.6A 0.3A ±5% ±1% - 12V Fixed 2.2A 2.6A 0.22A ±10% ±1% TPS180-44 +48V Fixed 2.2A 2.6A 0.22A ±10% ±1% 210W Typical + 5V ±10% Typical 18 A 21.6A 1.8A ±5% ±1% +12V Fixed 6.3A 7.6A 0.63A ±5% ±1% - 12V Fixed 1.2A 1. 4A 0.12A ±10% ±1% TPS180-45 +24V Fixed 1.8A 2.2A 0.18A ±10% ±1% 210W Typical + 5V ±10% Typical 6 A 7.2A 0.6A ±5% ±1% -15V Fixed 1.85A 2.2A 0.19A ±5% ±1% +15V Fixed 1.2A 1.4A 0.12A ±10% ±1% TPS180-46 +24V Fixed 6 A 7.2A 0.6A ±10% ±1% 210W Typical + 5V ±10% Typical 19A 22.8A 1.9A ±5% ±1% +15V Fixed 1.65A 2A 0.17A ±5% ±1% - 15V Fixed 1.65A 2A 0.17A ±10% ±1% TPS180-47 + 48V Fixed 1.65A 2A 0.17A ±10% ±1% 210W Typical + 5V ±10% Typical 20A 26A 2A ±5% ±1% +3.3V Fixed 15A 22.5A 1.5A ±5% ±1.5% +12V Fixed 2 A 2.6A 0.2A ±10% ±1% TPS180-48Y -12V Fixed 2 A 2.6A 0.2A ±10% ±1% 210W Typical + 5V ±10% Typical 20A 26A 2A ±5% ±1% +3.3V Fixed 15A 22.5A 1.5A ±5% ±1.5% +12V Fixed 2 A 2.6A 0.2A ±10% ±1% TPS180-49Y + 24V Fixed 1 A 1.3A 0.1A ±10% ±1% 210W Typical NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load . 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal lin e, 0.1μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requ irement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. 7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover. TOTAL POWER, INT. TEL: 877-646-0900 FAX: 978-453-7395 E-mail: sales@total-power.com http ://www.total-power.com -3-