TPS-150 TOTAL-POWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
TPS150 SWITCHING MODE 130W U CHANNEL POWER SUPPLIES KEY FEATURES *Universal input *Built-in EMI filter *Optional remote sense on main output *Optional constant current charger *Optional Power Good signal/Optional cover *Optional ±12VDC/±24VDC/±48VDC input
APPLICATIONS
- Telecommunications/Medical machines *Computer peripherals/Business machines *Test & industrial equipments ELECTRICAL SPECIFICATIONS INPUT Class B conducted, EN55022 class B Conducted *Line regulation----- +/- 0.5% typical OUTPUT *Maximum power---- 130W convection (Refer next page) n o m i n a l l i n e *Overload protection-Short circuit protection *Overvoltage n o m i n a l o u t p u t (Optional +/- 0.5% per inquiry) 180W 130W 80W 30W 65W Power Derating Curve 0 10 20 30 40 50 60 70 Ambient Temperature( °°°° C) Natural Convection Cooling Output Power (Watts) EMI & EMC *FCC part 15, Class B *CISPR 22 / EN55022, Class B *VCCI ,Class 2 *CE,EN 61000-3-2 (Class A) (Optional) and –3; SAFETY APPROVAL *UL1950 / c UL *Optional CSA 22.2, LEVEL 3 (COMPLY WITH) *TUV EN60950 *Optional UL 2601 (EMI Class A)(COMPLY WITH) ENVIRONMENTAL *Operating temperature : 0 t o 50℃ambient; derate each output at 2.5% per degree from 50 ℃to 70℃ *Humidity: Operating; non-condensing, 5% to 95% *Vibration : 10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis *Storage temperature: -40 to 85 ℃ *Temperature coefficient: +/- 0.05% per degree C *MTBF demonstrated: >100,000 hours at full load and 25 ℃ambient conditions
PPS150 SWITCHING MODE 130W U CHANNEL POWER SUPPLIES MODEL OUTPUTVO LTAGE ADJUSTMENT RANGE MAXIMUM OUTPUTCURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) SINGLE OUTPUT MODEL SELECTION CHART TPS150-10 +5V ±10% Typical 26A 42A 0A ±3% ±1% 210W Typical TPS150-11 +12V ±10% Typical 11A 17.6A 0A ±3% ±1% 210W Typical TPS150-12 +15V ±10% Typical 8.7A 13.9A 0A ±3% ±1% 210W Typical TPS150-13 +24V ±10% Typical 5.5A 8.8A 0A ±3% ±1% 210W Typical TPS150-14 +48V ±10% Typical 2.7A 4.3A 0A ±3% ±1% 210W Typical TPS150-15 +36V ±10% Typical 3.6A 5.8A 0A ±3% ±1% 210W Typical TPS150-16 +56V ±10% Typical 2.35A 3.8A 0A ±3% ±1% 210W Typical TPS150-17 +18V ±10% Typical 7.25A 11.6A 0A ±3% ±1% 210W Typical TPS150-18 +3.3V ±10% Typical 26A 41.6A 0A ±5% ±1.5% 210W Typical DUAL OUTPUT MODEL SELECTION CHART +5 V ±10% Typical 15A 24A 1.5A ±5% ±1%TPS150-20 +12V Fixed 6.3A 10.1A 0.63A ±5% ±1% 210W Typical +5 V ±10% Typical 15A 24A 1.5A ±5% ±1%TPS150-21 +24V Fixed 3.3A 5.3A 0.33A ±5% ±1% 210W Typical +5 V ±10% Typical 15A 24A 1.5A ±5% ±1%TPS150-22 - 5 V Fixed 15A 24A 1.5A ±5% ±1% 210W Typical +12V ±10% Typical 6.3A 10.1A 0.63A ±5% ±1%TPS150-23 - 12 V Fixed 6.3A 10.1A 0.63A ±5% ±1% 210W Typical +15 V ±10% Typical 5A 8A 0.5A ±5% ±1%TPS150-24 - 15 V Fixed 5A 8A 0.5A ±5% ±1% 210W Typical +12 V Fixed 6.3A 10.1A 0.63A ±5% ±1% 210W Typical + 12V ±10% Typical 7.1A 11.4A 0.71A ±5% ±1%TPS150-26 + 24V Fixed 2.7A 4.3A 0.27A ±5% ±1% 210W Typical + 10.3V ±10% Typical 6.3A 10.1A 0.63A ±5% ±1%TPS150-27 + 24V Fixed 3.6A 5.8A 0.36A ±5% ±1% 210W Typical + 5V ±10% Typical 20A 32A 2A ±5% ±1%TPS150-28 210W Typical TRIPLE OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +12V Fixed 6A 9.6A 0.6A ±5% ±1%TPS150-30 - 5 V Fixed 0.9A 1.4A 0.09A ±10% ±1% 210W Typical + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +12V Fixed 6A 9.6A 0.6A ±5% ±1%TPS150-31 -12V Fixed 0.9A 1.4A 0.09A ±10% ±1% 210W Typical + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +15V Fixed 4A 6.4A 0.4A ±5% ±1%TPS150-32 -15V Fixed 1A 1.6A 0.1A ±10% ±1% 210W Typical + 5V ±10% Typical 21A 33.6A 2.1A ±5% ±1% +15V Fixed 3A 4.8A 0.3A ±5% ±1%TPS150-33 - 5 V Fixed 0.9A 1.4A 0.09A ±10% ±1% 210W Typical + 5V ±10% Typical 19.2A 30.7A 1.92A ±5% ±1% +15V Fixed 3A 4.8A 0.3A ±5% ±1%TPS150-34 -12V Fixed 0.9A 1.4A 0.09A ±10% ±1% 210W Typical + 5 V ±10% Typical 13.8A 22.1A 1.38A ±5% ±1% -12V Fixed 0.9A 1.4A 0.09A ±5% ±1%TPS150-35 +24V Fixed 3A 4.8A 0.3A ±10% ±1% 210W Typical + 5V ±10% Typical 13.8A 22.1A 1.38A ±5% ±1% +12V Fixed 6A 9.6A 0.6A ±5% ±1%TPS150-36 - 12V Fixed 1.5A 2.4A 0.15A ±10% ±1% 210W Typical + 5V ±10% Typical 13.8A 22A 1.38A ±5% ±1% +12V Fixed 5.4A 8.6A 0.54A ±5% ±1%TPS150-37 +24V Fixed 0.8A 1.3A 0.08A ±10% ±1% 210W Typical + 5V ±10% Typical 6.7A 10.7A 0.67A ±5% ±1% +24V Fixed 1.8A 2.9A 0.18A ±5% ±1% TPS150-38 +12V Fixed 6A 9.6A 0.6A ±10% ±1% 210W Typical
PPS150 SWITCHING MODE 130W U CHANNEL POWER SUPPLIES MODEL OUTPUTVO LTAGE ADJUSTMENT RANGE MAXIMUM OUTPUTCURRENT PEAK OUTPUT CURRENT(NOTE1) MINIMUM OUTPUT CURRENT TOTAL REGULATION(NOTE3) RIPPLE & NOISE %P-P(NOTE2) PEAK OUTPUT POWER(NOTE1) TRIPLE OUTPUT MODEL SELECTION CHART +18V ±10% Typical 4A 6.4A 0.4A ±5% ±1% - 18V Fixed 4A 6.4A 0.4A ±5% ±1% TPS150-39 + 5V Fixed 2A 3.2A 0.2A ±10% ±1% 210W Typical QUAD OUTPUT MODEL SELECTION CHART + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +12V Fixed 5.3A 8.5A 0.53A ±5% ±1% - 12V Fixed 0.8A 1.3A 0.08A ±10% ±1% TPS150-40 - 5 V Fixed 0.8A 1.3A 0.08A ±10% ±1% 210W Typical + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +12V Fixed 4.2A 6.7A 0.42A ±5% ±1% - 12V Fixed 1.5A 2.4A 0.15A ±10% ±1% TPS150-41 - 5 V Fixed 1.5A 2.4A 0.15A ±10% ±1% 210W Typical + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +12V Fixed 2.7A 4.3A 0.27A ±5% ±1% - 15V Fixed 1.5A 2.4A 0.15A ±10% ±1% TPS150-42 +15V Fixed 1.5A 2.4A 0.15A ±10% ±1% 210W Typical + 5V ±10% Typical 9A 14.4A 0.9A ±5% ±1% +12V Fixed 3.5A 5.6A 0.35A ±5% ±1% - 12V Fixed 1.5A 2.4A 0.15A ±10% ±1% TPS150-43 - 15V Fixed 3A 4.8A 0.3A ±10% ±1% 210W Typical + 5V ±10% Typical 9A 14.4A 0.9A ±5% ±1% +12V Fixed 1.5A 2.4A 0.15A ±5% ±1% - 12V Fixed 1.5A 2.4A 0.15A ±10% ±1% TPS150-44 +48V Fixed 1.5A 2.4A 0.15A ±10% ±1% 210W Typical + 5V ±10% Typical 15A 24A 1.5A ±5% ±1% +12V Fixed 2A 8.5A 0.2A ±5% ±1% - 12V Fixed 1A 1.6A 0.1A ±10% ±1% TPS150-45Y +24V Fixed 1.5A 2.4A 0.15A ±10% ±1% 210W Typical + 5V ±10% Typical 4A 6.4A 0.4A ±5% ±1% - 15V Fixed 1.25A 2A 0.13A ±5% ±1% +15V Fixed 0.8A 1.3A 0.08A ±10% ±1% TPS150-46 +24V Fixed 4A 6.4A 0.4A ±10% ±1% 210W Typical + 5V ±10% Typical 13A 20.8A 1.3A ±5% ±1% +15V Fixed 1.1A 1.76A 0.11A ±5% ±1% - 15V Fixed 1.1A 1.76A 0.11A ±10% ±1% TPS150-47 +48V Fixed 1.1A 1.76A 0.11A ±10% ±1% 210W Typical + 5V ±10% Typical 12.5A 20A 1.25A ±5% ±1% +3.3V Fixed 9A 14.4A 0.9A ±5% ±1.5% +12V Fixed 2.5A 4A 0.25A ±10% ±1% TPS150-48 -12V Fixed 2.5A 4A 0.25A ±10% ±1% 210W Typical + 5V ±10% Typical 12.5A 20A 1.25A ±5% ±1% +3.3V Fixed 9A 14.4A 0.9A ±5% ±1.5% +12V Fixed 2.5A 4A 0.25A ±10% ±1% TPS150-49 +24V Fixed 1A 1.6A 0.1A ±10% ±1% 210W Typical NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load . 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1 μF and 47μF Cap. on outputs. 3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requ irement is welcomed. 4) Detailed engineering specification of each model is available for inquiry. 5) Special output voltage/current inquiry is welcomed. 6) Specifications subject to change without notice. 7) 25% derated if 24 VDC input version; 50% derated, if 12 VDC input version; 25% derated if additional cover.