TPRSDR-120-XS TOPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page1 / 6 DESCRIPTION: The rated output power of TPR/SDR-120-XS series is 100~120W ,input voltage range:85-264VAC, output voltage : 12V, 24V, 48V,High reliability, precision,effificency , ultra-small size, stable output voltage and etc, EMI filter circuit, the rectifier filter circuit, , with short circuit & overload protection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control , New Energy, Security,and other electronic systems. 100~120W AC-DC DIN RAIL Power Supply All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. OUTPUT CHARACTERISTICS Conditions Conditions Parameter Output voltage regulation 12V output voltage 12-14V 24V output voltage 24-28V 48V output voltage 48-56V Rated Output current 12V output voltage 8.33A at 12V 7.15A at 14V 24V output voltage 5A at 24V 4.5A at 28V 48V output voltage 2.5A at 48V 2.25A at 56V Rated Output power 12V output voltage 100W/12V 24V output voltage 120W/24V , 126W/28V 48V output voltage 120W/48V , 126W/56V Ripple&Noise0<Ta≤70℃ 12V 24V output voltage ≤120mVp-p 48V output voltage ≤240mVp-p Ripple&Noise-25<Ta≤0℃ 12V output voltage ≤200mVp-p 24V 48V output voltage ≤240mVp-p Capacitive load capacity 12V output voltage 5000uF 24V output voltage 3500uF 48V output voltage 1250uF Line regulation @-20~65℃ ±0.5% Load regulation @-20~65℃ ±1.0% Temp. coefficient @-20~65℃ ±0.03%/℃ Set-up time @25℃ ≤250mS@ 230Vac input ≤500mS@ 100Vac Hold-up time @25℃ ≥20mS@ (230Vac input, Full load) Overshoot&Undershoot <5.0%
FEATURES
AC input :85VAC-264VAC,DC input:127-360VDC Built-in DC OK relay contact,Excellent Partial Load Efficiency Operating temperature:-25℃~70℃ Mounting track: TS-35/7.5 or TS-35/15 Protection:short circuit,over-load,over-voltage,over-temperature Mini width: 32mm RoHS complaint High reliability,effificency,100% full load burn-in test Built-in current limiting circuit Built-in active PFC,PF>0.95 Easy Fuse Tripping due to High Overload Current 150%(180W) peak load capacity SELECTION GUIDE Part Number Input Volatge Output Efficiency @25 ℃, (Typ)% (VAC) (VDC) Voltage (VDC) Pre-set voltage @25 ℃(V) Rated current(A) Rated power(W) Rated Range Rated Range TPR/SDR-120-12S 220 85-264 127-360 12 12.00-12.10 8.33 120 89.5 TPR/SDR-120-24S 220 85-264 127-360 24 24.00-24.20 5.00 120 91 TPR/SDR-120-48S 220 85-264 127-360 48 48.0-48.40 2.50 120 92 TOPPOWER
www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page2 / 6 INPUT CHARACTERISTICS Conditions Parameter Input voltage range 85VAC~264 VAC input voltage range 127VDC-360VDC Frequency Range 47Hz~63Hz Set-up voltage @-20~65℃ <85 VAC <127VDC Inrush current @25℃ <30A@100 Vac input <60A@230Vac input PROTECTION Conditions Parameter Notes Over-Load (12Voutput) 10.7~12.5A Limit output current Over-Load (24Voutput) 6.7~7.5A Over-Load (48Voutput) 3.375~3.75A Over-voltage(12Voutput) 15~18V Protection type:Locked, auto recovery Over-voltage(24Voutput) 29~33V Over-voltage(48Voutput) 58~65V Over-temperature Protection type: power-off , recovery after restart Output short circuit protection Long-term model , auto recovery ENVIRONMENT CHARACTERISTICS Conditions Parameter Operating amb. Temp.&Humi. (12V output) -25℃~70℃; 20%~90%RH No condensing 60℃~70℃ 2.5W/℃ derating Operating amb. Temp.&Humi. (24V output) -25℃~70℃; 20%~90%RH No condensing 60℃~70℃ 3W/℃ derating Operating amb. Temp.&Humi. (48V output) -25℃~70℃; 20%~90%RH No condensing 60℃~70℃ 3W/℃ derating Storage Temp. & Humi. -40℃~85℃; 5%~95%RH No condensing Vibration 10 ~ 500Hz, 2G,10min./1cycle, each along X,Y, Z axes IEC 60068-2-6 Pulse 20G/11mS pulse ,3 times at each X,Y,Z axes IEC 60068-2-27 Altitude 6000m SAFETY&EMC STANDARDS @25℃ Conditions Parameter Safety Standards GB4943 ,EN60950 (for reference) Withstand Voltage I/P-O/P:3.0KVac/10mA; I/P-FG:2.5KVac/10mA; O/P-FG:0.5KVdc/20mA O/P- DC OK :0.5KVdc/1mA Test time:1min. Isolation resistance 1I/P-O/P: 10M ohms; I/P-FG : 10M ohms; O/P-FG : 10M ohms Grounding test 12V,48V: Test condition:32A/1min 24V: Test condition:32A/2min.; Grounding resistance:<0.1 ohms Leakage Current @ 25℃ I/P-Grounding≤3.5mA ; I/P-O/P ≤0.25mA (264Vac input, 63Hz) EMC emission Compliance to EN55022, EN55024, FCC PART 15 CLASS B EMC immunity Compliance to EN61000-4-2,3,4,5,6,11 heavy industry level Harmaonic current EN61000-3-2,CLASS A TOPPOWER
www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page3 / 6 OTHERS Conditions Parameter Net Weight 0.53kg Dimension (L*W*H) 124*119*32mm Cooling method Cooling by free air flow Series / parallel function yes DC OK relay contact rating Max 30V/1A or 60V/0.3A or 30Vac/0.3A Resistive load DC OK LED V On: when output voltage is up to 90% of rated output voltage, V Off: when output voltage is down to 80% of rated output voltage RELIABIILITY CHARACTERISTICS Conditions Parameter MTBF 300,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method MECHANICAL DIMENSIONS TOPPOWER
www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page4 / 6 DERATING CURVE TOPPOWER
www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page5 / 6 MOUNTING METHOD INSTRUCTION A1 is recommended output current , A2 is the allowed max output current (PSU lifetime is around half of A1) 12V output Mounting 1: Mounting 2: Mo unting 3: Mounting 4: Mo unting 5: 24V output Mounting 1: Mounting 2: Mo unting 3: Mounting 4: Mo unting 5: 48V output Mounting 1: Mounting 2: Mo unting 3: Mounting 4: Mo unting 5: TOPPOWER
www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page6 / 6 BLOCK DIAGRAM MODEL SELECTION S:Single ouput;D:Dual output Delimiter Type DIN RAIL Series Brand TOPPOWER Delimiter Output voltage TP C / SDR -120 – 12 SS SS Rated output Power Delimiter TOPPOWER