TPRNDR-U120-XS TOPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page1 / 6 DESCRIPTION: The rated output power of TPR/NDR-U120-XS series is 120W,input voltage range:90-264VAC, output voltage : 12V, 24V, 48V,High reliability, precision,effificency , ultra-small size, stable output voltage and etc, EMI filter circuit, the rectifier filter circuit, , with short circuit & overload protection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control , New Energy, Security,and other electronic systems. 120120120120WW WW AC-DC DIN RAIL Power Supply All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. without Built-in active PFC OUTPUT CHARACTERISTICS Conditions Conditions Parameter Output voltage regulation 12V output voltage 12-14V 24V output voltage 24-28V 48V output voltage 48-56V Rated Output current 12V output voltage 10A at 12V 9A at 14V 24V output voltage 5A at 24V 4.5A at 28V 48V output voltage 2.5A at 48V 2.25A at 56V Rated Output power 12V output voltage 120W/12V , 126W/14V 24V output voltage 120W/24V , 126W/28V 48V output voltage 120W/48V , 126W/56V Ripple&Noise0<Ta≤70℃ 12V 24V output voltage 120mVp-p 48V output voltage 240mVp-p Ripple&Noise-20<Ta≤0℃ 12V 24V output voltage 240mVp-p 48V output voltage 480mVp-p Capacitive load capacity 12V output voltage 5000uF 24V output voltage 3500uF 48V output voltage 1250uF Line regulation @-20~65℃ ±0.5% Load regulation @-20~65℃ ±1% Temp. coefficient @-20~65℃ ±0.03%/℃ Set-up time @25℃ ≤2500mS@ 115Vac input ≤1200mS@ (230Vac input, Full load) Hold-up time @25℃ ≥10mS@ 115Vac input ≥20mS@ (230Vac input, Full load) Overshoot&Undershoot <5.0%

FEATURES

AC input :90VAC-264VAC,DC input:127-370VDC High efficiency up to 88% Operating temperature:-20 ℃~70℃ Mounting track: TS-35/7.5 or TS-35/15 Protection:short circuit,over-load,over-voltage,over-temperature Mini width: 45mm RoHS complaint High reliability,effificency,100% full load burn-in test Built-in current limiting circuit SELECTION GUIDE Part Number Input Volatge Output Efficiency @25 ℃, (Typ)% (VAC) (VDC) Voltage (VDC) Pre-set voltage @25 ℃(V) Current (A) Rated power(W) Rated Range Rated Range TPR/NDR-U120-12S 220 90-264 127-370 12 12.00-12.10 10 120 85 TPR/NDR-U120-24S 220 90-264 127-370 24 24.00-24.20 5 120 88 TPR/NDR-U120-48S 220 90-264 127-370 48 48.0-48.40 2.5 120 88 TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page2 / 6 INPUT CHARACTERISTICS Conditions Parameter Input voltage range 100VAC~240 VAC input voltage range 127VDC-370VDC Frequency Range 47Hz~63Hz Set-up voltage @-20~65℃ 90 VAC (refer to the derating curve) <120VDC at 12 ,<127VDC at 24V ,48V Inrush current @25℃ <20A@115 Vac input <35A@230Vac input PROTECTION @-20~65℃ Conditions Parameter Notes Over-Load (12Voutput) 10.5~13A Limit output current Over-Load (24Voutput) 5.25~6.5A Over-Load (48Voutput) 2.75~3.25A Over-voltage(12Voutput) 15~18V Protection type:Locked, auto recovery Over-voltage(24Voutput) 29~33V Over-voltage(48Voutput) 58~63V Over-temperature Ambient at 83℃&rated input,full-load output Protection type: power-off , recovery after restart Output short circuit protection Long-term model , auto recovery ENVIRONMENT CHARACTERISTICS Conditions Parameter Operating amb. Temp.&Humi. (12V output) -20℃~70℃; 20%~90%RH No condensing 45℃~70℃ 2.5W/℃ derating Operating amb. Temp.&Humi. (24V output) -20℃~70℃; 20%~90%RH No condensing 50℃~70℃ 3W/℃ derating -10℃~-20℃ 2.4W/℃ derating Operating amb. Temp.&Humi. (48V output) -20℃~70℃; 20%~90%RH No condensing 115VAC 50℃~70℃ 3W/℃ derating,230VAC 55℃~70℃4W/℃ derating Storage Temp. & Humi. -40℃~85 ℃; 5%~95%RH No condensing Vibration 10 ~ 500Hz, 2G,10min./1cycle, period for60min. each along X,Y, Z axes IEC 60068-2-6 Pulse 20G/11mS pulse ,3 times at each X,Y,Z axes IEC 60068-2-27 Altitude 6000m SAFETY&EMC STANDARDS @25℃ Conditions Parameter Safety Standards GB4943 ,EN60950 (for reference) Withstand Voltage 12V : I/P-O/P:3.0KVac/10mA; I/P-FG:2KVac/10mA; O/P-FG:0.5KVdc/10mA test time:1min. 24V48V : I/P-O/P:3.0KVac/10mA; I/P-FG:1.5KVac/10mA; O/P-FG:0.5KVdc/20mA test time:1min. Isolation resistance 12V : I/P-O/P: 10M ohms; I/P-FG : 10M ohms; O/P-FG : 10M ohms 24V48V : I/P-O/P: 100M ohms; I/P-FG : 100M ohms; O/P-FG : 100M ohms Grounding test Test condition:32A/1min.;Grounding resistance:<0.1 ohms. Leakage Current @ 25℃ I/P-Grounding≤3.5mA; I/P-O/P ≤0.25mA (264Vac input, 63Hz) EMC emission Compliance to EN55022, EN55024, FCC PART 15 CLASS B EMC immunity Compliance to EN61000-4-2,3,4,5,6,11 heavy industry level Harmaonic current EN61000-3-2,CLASS A TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page3 / 6 OTHERS Conditions Parameter Cooling method Cooling by free air flow Dimension (L*W*H) 45*124*119mm Net Weight 0.59kg Series function yes DC OK LED Green light RELIABIILITY CHARACTERISTICS Conditions Parameter MTBF 500 ,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method MECHANICAL DIMENSIONS TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page4 / 6 DERATING CURVE TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page5 / 6 MOUNTING METHOD INSTRUCTION A1 is recommended output current , A2 is the allowed max output current (PSU lifetime is around half of A1) 12V output Mounting 1: Mounting 2: Mo unting 3: Mounting 4: Mo unting 5: 24V output Mounting 1: Mounting 2: Mo unting 3: Mounting 4: Mo unting 5: 48V output Mounting 1: Mounting 2: Mo unting 3: Mounting 4: Mo unting 5: TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page6 / 6 BLOCK DIAGRAM MODEL SELECTION S:Single ouput;D:Dual output Delimiter Type DIN RAIL Series Brand TOPPOWER Delimiter Output voltage TP C / NDR –U120 – 12 SS SS Rated output Power Delimiter TOPPOWER