TPMPU12A TOTAL-POWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Electrical Characteristics: TPMPU12A SERIES 12W Wall Mount Switching Power Supplies For Medical Equipment Description: Features: Sym. Parameter Test Conditions Min. Typ. Max. Unit Vin Input Voltage Operating Voltage 90 264 VAC fin Input Frequency 47 63 Hz Po Output Power Range Vin=90 to 264VAC 0 12 W Vo Output Voltage Range See rating chart V Io Output Current Range See rating chart A Iil Input Current (Low Line) Io=Full load, Vin=115VAC 0.25 0.35 A Iih Input Current (High Line) Io=Full load, Vin=230VAC 0.17 0.22 A Irl Low Line Inrush Current Io=Full load, 25c, Cool start, Vin=115VAC 14 16 A Irh High Line Inrush Current Io=Full load, 25c, Cool start, Vin=230VAC 28 30 A Eff Efficiency Io=Full Load, Vin=230VAC 70.8 72 85 % REG-i Line Regulation Io=Full Load 0.5 1 % REG-o Load Regulation Vin=230VAC 3 5 % OVP Over Voltage Protection 112 132 % OCP Over Current Protection 110 150 % Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4 mS Thold Hold-Up Time Io=Full Load, Vin=110VAC 10 16 mS Ts Start Up Time Io=Full Load, Vin=100VAC 0.3 1 2 S Vrn Ripple & Noise(Peak to Peak) Full Load, Vin=90VAC 0.5 1 % TC Temperature Coefficient All output -0.04 0.04 %/c Tjsd Thermal Shutdown ○1 by Junction Temperature Controller The parameter is not subject to production test-verified by design/characterization of integrated controller. -25 130 c Safety Approvals: Wide Input Voltage 90 to 264 VAC,47 to 63 Hz

2 Prong Plug-In Mains Connector

Output Voltage Available From 5VDC Thru 27VDC Optional Output Connector (See appendix) Single Output Class II Over Voltage and Over Load protection. Over temperature Detection 3 year warranty The 12A series of AC/DC switching mode power supplies provide 12 watts of continuous output power. This series is suitable for use in Blood Pressure measurements, Frequency Therapy Device and Dental Curing light applications. All models are designed to comply with UL/c-UL(UL60601-1), and new CE requirements. Environmental : Hr Relative Humidity 5 95 % Toper Operating Temperature Tstg Storage Temperature Pd 0 70 50 85 -40 Sym. Parameter Min. Typ. Max. Unit Derate linearly from 100% load at 50 C to 50% load at 70 C Test Conditions C C No-Condensing As long as faulty conditions have been removed , the adaptor will automatically power up as usual.○1 Hrs M MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1 S E P

12W Wall Mount Switching Power Supplies For Medical Equipment Safety Specifications: Output Voltage And Current Rating Chart ( Single Output ) : Mechanical Specifications:( USA Type) Note: 1. Dimensions are shown in mm. 2. Weight: 130gs approx. 3. Optional output connector: See page Appendix. Model Number Output Voltage Output Current Total Regulation Maximum Output Power TPMPU12A-102 5 ~ 6 VDC 2.00 ~ 1.66 A 5% 10W TPMPU12A-103 6 ~ 8 VDC 2.00 ~ 1.50 A 5% 12W TPMPU12A-104 8 ~ 11 VDC 1.50 ~ 1.09 A 5% 12W TPMPU12A-105 11 ~ 13 VDC 1.09 ~ 0.92 A 5% 12W TPMPU12A-106 13 ~ 16 VDC 0.92 ~ 0.75 A 5% 12W TPMPU12A-107 16 ~ 21 VDC 0.75 ~ 0.57 A 3% 12W TPMPU12A-108 21 ~ 27 VDC 0.57 ~ 0.44 A 3% 12W (OPTIONAL) Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 5803 VDC Sym. Vps Vin=120VAC, 60Hz B CLASSCISPR FCC Meet EMI requirements: CISPR-11 Vin=120VAC, 60Hz B CLASSMeet EMI requirements: CRF 47, Part18 The total regulation on model 102~103 is required to use AWG#18 / 6FT output cable. The total regulation on model 104~108 is required to use AWG#20 / 6FT output cable. The regulation and efficiency will be changed by modified output cable.