TPIMP151 TOTAL-POWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

UNIVERSAL INPUT HARMONIC CORRECTION AC-DC MEDICAL AND IEC APPLICATION OPEN FRAME SINGLE & MULTI-OUTPUT 150 WATTS INTERNAL SWITCHING POWER SUPPLIES TPIMP151 SERIES FEATURES: „ 5” X 3”* X 1.38” COMPACT SIZE „ ACCOMMODATE UNIVERSAL AC SOURCES „ MEET IEC 61000-3-2 HARMONIC CORRECTION „ MEET UNIVERSAL SAFETY STANDARDS „ EMI MEET CISPR EN 55022/EN 55011 & FCC CLASS B C ONDUCTED „ CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: V-M connector. Input Frequency: 47-63Hz. Inrush Current: 9.3-11.3Arms @230Vac. Input Current: Typ. 2.2A @115Vac, 0.9A @230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR EN 55022 & FCC Class B conducted. Meet CISPR EN 55011 & FCC Class B conducted. Hold-up Time: Typ. 90mS @115Vac & 230Vac. Power Factor & Harmonic Correction: Meet IEC 61000-3-2, PF typ. 0.99 @ full load. Over Temperature Protection: Installed. Leakage Current: 0.40-0.50mA @230Vac touch current. OUTPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: V-M connector. Output Wattage: Max. 150 watts. Line Regulation: Typ. 1.0%. Load Regulation: Single O/P VO1 ±3.0%. Dual O/P VO1 ±3.0% VO2 ±1.0% Triple O/P VO1 ± 3.0% (± 8% for 3.3V), VO2/VO3 ±3.0%. Quad O/P VO1/VO2/VO3/VO4 ±3.0% Noise & Ripple: Typ. 1.0-2.0% peak to peak. OVP: Built-in at VO1 and VO2. Adjustability: Available at VO1 and VO2. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typ. 76-80% various with output. Switching Frequency: 68K Hz. Circuit Topology: Single Fixed frequency forward circuit. Dual/Triple/Quad: Fixed freq. flyback circuit. Transient Response: Output voltage returns in less than 14.8-25.2mS following a 25% load change. Safety Standard: IEC 60950-1 Class I for IEC use. IEC 60601-1 Class I for Medical use. Operating Temperature: 0 to +50°C under 30 CFM forced air cooling for full load. Storage Temperature: -20 to +85°C. Temperature Coefficient: Typ. 0.04% /°C. Cooling: Requested 30 CFM forced air flow for full load. Construction: U-bracket format. Power Density: 6.52-7.24 Watts / Cubic Inch . Note: Due to requests in market and advances in technology, specifications subject to change without notification. Total Power International, Inc. Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com Total Power International, Inc.

OUTPUT VOLTAGE / CURRENT RATINGS CHART MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 385.0g (13.4 Oz.) DUAL OUTPUT (Under forced air cooling) TPIMP151-D050I 15.00A +5V 15.00A 6.00A +12V 6.00A TPIMP151-D050M 15.0A +5V 15.0A 3.00A +24V 3.00A TPIMP151-D120I 6.25A +12V 6.25A 6.25A +12V 6.25A TPIMP151-D150K 5.0A +15V 5.00A 5.00A +15V 5.00A SINGLE OUTPUT (Under air cooling) MAIN VO1 ★@ MODEL NO. Typ. Volt. Max. TPIMP151-S050270 27A 5V 30A TPIMP151-S120125 12.5A 12V 12.5A TPIMP151-S150100 10.0A 15V 10.0A TPIMP151-S240063 6.3A 24V 6.3A TRIPLE OUTPUT (Under forced air cooling) TPIMP151-T033EI 18A +3.3V 20A 13.5A +5V 15A 0.8A +12V 0.8A QUAD OUTPUT (Under forced air cooling) TPIMP151-Q050KKE 15A +5V 15A 4A +15V 4A 0.8A -15V 0.8A 0.5A -5V 0.5A Symbol: "★" OVP built-in. "@" Adjustable. " ●" Post –Regulated Remark: Please refer to the derating chart depending on ambient temperature and fan cooling. INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC I NPUT SINGLE O/P DUAL O/P TRIPLE O/P QUAD O/P ASSIGNMENT AC AC- N AC- G VO1 DC- COM VO1 VO2 DC- COM VO1 VO2 VO3 DC- COM VO1 VO2 VO3 +VO4 DC COM CNTR & PIN # P1- L P1- N P1- G P2-1,2, 3,4,5,6 P2-7,8,9 10,11,12 P2-1,2,3,

4 P2-9,10 P2-5,

6,7,8 P2-1,2, 6,7,8 P2-1, 7,8 Mating connector: Moles 5195 or 5239 series. SINGLE DUAL/TRIPLE/QUAD Total Power International, Inc.

rced air cooling- 5CFM Forced air cooling- 20CFM Forced air cooling- 30CFM Power derating 100 0 1 02 03 04 05 06 07 08 09 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C TP IMP151-D050I Forced air cooling- 5CFM Forced air cooling- 20CFM Forced air cooling- 23CFM Power derating 100 0 1 02 03 04 05 06 07 08 09 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C TP IMP151-T033EI Forced air cooling- 5CFM Forced air cooling- 20CFM Forced air cooling- 30CFM Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C Power derating 100 0 1 0 2 03 04 0 5 06 07 08 0 9 0 1 0 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C TP IMP151-Q050KKE Forced air cooling- 5CFM Forced air cooling- 20CFM Forced air cooling- 26CFM Power derating 100 0 1 02 03 04 05 06 07 08 09 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C Power derating 100 0 1 02 03 04 05 06 07 08 09 0 1 0 0 deg C Total Power International, Inc.