Technical content

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page 1 / 4 DESCRIPTION: The rated output power of TPC/LPD-100-XS series is 90-110.4W,input voltage range:90-264VAC, output voltage : 5V,12V,15V,24V,28V,36V,48V,High reliability, precision,effificency , ultra-small size, no external heat sink required, stable output voltage and etc, with short circuit, over-load,over-voltage protection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control , New Energy, Security,and other electronic systems. 100W Wide input AC/DC switching power supply All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. OUTPUT CHARACTERISTICS Conditions Conditions Parameter Ripple and noise,Ta is ambient ,@25 ℃ 12V output voltage ≤120mVp-p 15V output voltage ≤150mVp-p 24V,28V,36V,48V output voltage ≤200mVp-p Output adjustment range @25℃ 5V output voltage 4.5V-5.5V 12V output voltage 10.8V-13.2V 15V output voltage 13.5V~16.5V 24V output voltage 21.6V-26.4V 28V output voltage 25.2V-30.8V 36V output voltage 32.4V~39.6V 48V output voltage 43.2V-52.8V Voltage regulation accuracy@-30~70℃ ±3% @5V , ±1% @12V 15V 24V 28V 36V 48V Line regulation@-30~70℃ ±0.5% Load regulation@-30~70℃ ±1.0% Temp. coefficient@-25~70℃ ±0.03%/℃ Set-up time@25℃ ≤500mS / 30mS ( 230Vac/115Vac input, full load ) Hold-up time@25℃ ≥20mS(230Vac input, Full load) ≥10mS(115Vac input, Full load) Overshoot&Undershoot@-30~70℃ <5.0%

FEATURES

Universal AC input :90VAC-264VAC 100% full load burn-in test short circuit, over-load,over-voltage protection Operating temperature:-30℃~70 ℃ RoHS complaint Low standby power consumption<0.5W All using 105℃ long-life electrolytic capacitors High reliability,effificency ,long life Can bear 300VAC for 5s, 1U low profile SELECTION GUIDE Part Number Input Output Efficiency @25 ℃, (Typ)% Volatge(VAC) Voltage (VDC) Pre-set voltage @25 ℃(V) Rated current (A) Current range(A) Rated power(W) Rated Range values TPC/LPD-100-5S 220 90-264 5 5.00-5.10 18.0 0-18 90 86 TPC/LPD-100-12S 220 90-264 12 12.00-12.20 8.5 0-8.5 102 87 TPC/LPD-100-15S 220 90-264 15 15.00-15.20 7.0 0-7.0 105 88 TPC/LPD-100-24S 220 90-264 24 24.00-24.20 4.5 0-4.5 108 90 TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page 2 / 4 INPUT CHARACTERISTICS Conditions Parameter Input voltage range 90Vac~264Vac 120-370VDC Max. input voltage 300Vac input,no damage,dwell time 5000 mS Rated input voltage range 100Vac~240Vac 120-370VDC Frequency Range 47Hz~63Hz Set-up voltage@-30~70℃ 90Vac(refer to the derating curve) Input current@25℃ ≤1.9A@115Vac / ≤1.2A@ 220Vac Inrush current @25℃ ≤65A@230Vac Cold start Standby power@25℃ <0.5W PROTECTION @-30~70℃ Conditions Parameter Over-power 110%~180% of rated power, Hiccup mode, auto recovery Over-voltage 115%~150% of rated output voltage, constant voltage, auto recovery Over-load 110%~180% of rated current, Hiccup mode, auto recovery Output short circuit protection Long-term mode, Auto recovery ENVIRONMENT CHARACTERISTICS Conditions Parameter Operating amb. Temp.&Humi. -30℃~70 ℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Humi. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz, 5G 10min./1cycle, period for60min. each along X,Y, Z axes Pulse 20G/11mS pulse ,3 times at each X,Y,Z axes Altitude 5000m SAFETY&EMC STANDARDS @25℃ Conditions Parameter Safety Standards Meet UL60950-1, TUV EN60950-1, EN61558-1/-2-16,CCC GB4943 Withstand Voltage I/P-O/P:3.75KVac/10mA; I/P-FG:2.0KVac/10mA; O/P-FG:0.5KVdc/10mA test time:1min. Grounding test Test condition:40A/2min.;Grounding resistance:<0.1 ohms. Leakage Current I/P-Grounding≤0.75mA ; I/P-O/P ≤0.25mA 240Vac input 63Hz Isolation resistance I/P-O/P: 100M ohms; I/P-FG : 100M ohms; O/P-FG : 100M ohms EMC emission Compliance to EN55032 Class B/FCC Part15 Class B EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11 Harmonic Current Compliance to EN61000-3-2,CLASS A OTHERS Conditions Parameter Cooling method Cooling by free air flow Dimension (L*W*H) 129*97*30mm Net Weight 0.29kg RELIABIILITY CHARACTERISTICS Conditions Parameter MTBF 200,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page 3 / 4 MECHANICAL DIMENSIONS TOPPOWER

www.gztoppower.com TEL:0086-20-8 2019000 Email:sales2@gztoppower.com Page 4 / 4 BLOCK DIAGRAM DERATING CURVE MODEL SELECTION S:Single ouput;D:Dual output Delimiter Type Series Brand TOPPOWER Delimiter Output voltage TP C / LPD -100 – X S Rated output power Delimiter TOPPOWER