www.gztoppower.com TEL:0086-20-62162688 Email:sales2@gztoppower.com Page1 / 5 DESCRIPTION: The rated output power of TPC/PDF-1200-XS series is1200W,input voltage range:90-264VAC, output voltage:24V,36V,48V,High reliability, precision,effificency , ultra-small size, no external heat sink required, stable output voltage and etc, with over current protection,short circuit,overloadprotection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control , New Energy, Security,and other electronic systems. 1200W wide input AC/DC switching power supply All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. OUTPUT CHARACTERISTICS Conditions Conditions Parameter Ripple and noise,Ta is ambient ,0<Ta≤50℃ 24V 36V output voltage ≤150mVp-p Ripple and noise,Ta is ambient ,0<Ta≤50℃ 48V output voltage ≤200mVp-p Ripple and noise,Ta is ambient ,-25<Ta≤0℃ 24V 36V output voltage ≤150mVp-p Ripple and noise,Ta is ambient ,-25<Ta≤0℃ 48V output voltage ≤400mVp-p Dynamic load characterstics, -25<Ta≤50℃ 24V output voltage 5A-25A:Vp-p<1200mV 25A-50A: Vp-p<1200mV 5A-50A: Vp-p<1200mV (2mS) 36V output voltage 8.5A-17A:Vp-p<1200 mV 17A-25.5A: Vp-p<1200 mV 48V output voltage △V:≤ 5%Vo Output adjustment range @25℃ 24V output voltage 21~27V 36V output voltage 32~37V 48V output voltage 45~53V Rated output current 24V output voltage 50A at 176~246VAC input, 25A at 90~176VAC input 36V output voltage 34A at 176~246VAC input, 15A at 90~176VAC input 48V output voltage 25A Voltage regulation accuracy @-20~50℃ ±2% at 48V Voltage regulation accuracy @-25~50℃ ±1% at 24V 36V Line regulation @-25~50℃ ±0.5% Load regulation @-25~50℃ ±1% Temp. coefficient @-25~50℃ ±0.03%/℃ Set-up time @25℃ ≤2.0S@115Vac input ≤1.0S@(230Vac input, Full load) Hold-up time @25℃ ≥10mS@115Vac input ≥20mS@(230Vac input, Full load) Overshoot&Undershoot <5.0%
FEATURES
AC input :90VAC-264VAC short circuit, overload,over-voltage protection Operating temperature:-25℃~50℃ RoHS complaint High reliability,effificency,100% full load burn-in test Built-in active PFC function, PF>0.96 Build in DC OK signal Using ZVS technology to reduce power dissipation Built in AC inrush current limiting circuit(<20A) 1 U low profile,41mm Built in Fan speed control/Built in Remote Sense Function PCB soldering side with conformal coating SELECTION GUIDE Part Number Input Output Efficiency @25℃, (Typ)% Volatge(VAC) Voltage (VDC) Pre-set voltage @25℃(V) Rated current (A) Current range(A) Rated power(W) Rated Range TPC/PDF-1200-24S 220 90-264 24 24.00-24.10 25/50 0-50 1200 89 TPC/PDF-1200-36S 220 90-264 36 35.75-36.25 15/34 0-34 1200 89 TPC/PDF-1200-48S 220 90-264 48 48.00-48.10 25 0-25 1200 ≥90 TOPPOWER
www.gztoppower.com TEL:0086-20-62162688 Email:sales2@gztoppower.com Page2 / 5 INPUT CHARACTERISTICS Conditions Parameter Input voltage range 90Vac~264Vac Rated input voltage range 100Vac~240Vac (24V 36V) 200Vac~240Vac (48V) Frequency Range 47Hz~63Hz Set-up voltage @-20~65℃ 90Vac(refer to the derating curve) Input current @25℃ <10 A Inrush current @25℃ <10A@230Vac input 24V output <20A@230Vac input 36V output <30A@264Vac input 48V output Power Factor(Typical) PF≥0.96/230VAC PF ≥0.98/115VAC Full Load Leakage Current Input—output: ≤0.25mA Input—PG: ≤3.5mA PROTECTION @-20~65℃ Conditions Parameter Notes Over-Load 24V 36V 48V 105%~125% of rated current, constant current, auto recovery Over-power 24V 36V 48V 105%~125% of rated power, constant current, auto recovery Over-voltage 24V 36V 48V 110%~130% of rated output voltage, constant voltage Over-temperature 24V 36V 48V 115℃+5℃(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to 75℃ Output short circuit protection Long-term model , constant current,auto recovery ENVIRONMENT CHARACTERISTICS Conditions Parameter Operating amb. Temp.&Humi. -25℃~50℃; 20%~90%RH No condensing (refer to the derating curve) Storage Temp. & Humi. -40℃~85℃; 10%~95%RH No condensing Vibration 10 ~ 500Hz, 2G,10min./1cycle, period for60min. each along X,Y, Z axes Pulse 20G/11mS pulse ,3 times at each X,Y,Z axes Altitude 5000m (48V) 3000m (24V 36V) SAFETY&EMC STANDARDS @25℃ Conditions Parameter Safety Standards GB4943/EN60950 (for reference) Withstand Voltage I/P-O/P:3.0KVac/10mA; I/P-FG:1.5KVac/10mA; O/P-FG:0.5KVdc/10mA test time:1min. Isolation resistance I/P-O/P: 10M ohms; I/P-FG : 10M ohms; O/P-FG : 10M ohms Grounding test 24V/36V: Test condition:40A/1min.Grounding resistance:<0.1 ohms. 48V: Test condition:32A/2min.Grounding resistance:<0.1 ohms. DC OK signal 4~6V EMC emission Compliance to EN55022, CLASS B FCC PART15B EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11 heavy industry Leve Harmonic Current Compliance to EN61000-3-2,Class D OTHERS Conditions Parameter Cooling method Cooling by free air flow Dimension (L*W*H) 226*116.5*41mm Net Weight 1.22kg TOPPOWER
www.gztoppower.com TEL:0086-20-62162688 Email:sales2@gztoppower.com Page3 / 5 RELIABIILITY CHARACTERISTICS Conditions Parameter MTBF 200,000Hrs AT 25℃, MIL-217 Method 2 Components Stress Method MECHANICAL DIMENSIONS TOPPOWER
www.gztoppower.com TEL:0086-20-62162688 Email:sales2@gztoppower.com Page4 / 5 DERATING CURVE 24V 36V 48V 48V BLOCK DIAGRAM TOPPOWER
www.gztoppower.com TEL:0086-20-62162688 Email:sales2@gztoppower.com Page5 / 5 MODEL SELECTION S:Single ouput;D:Dual output Delimiter Type Series Brand TOPPOWER Delimiter Output voltage TP C / PDF -1200 – X S Rated output Power Delimiter TOPPOWER