TP75 ASTRODYNE | Alldatasheet
Document overview
- PDF pages: 4
Technical content
75W Triple Output with PFC Function TP75 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 Universal AC input Built-in active PFC function, PF >0.95 Protections: Short circuit / Overload / Over voltage Fixed switching frequency at PFC: 67KHz PWM: 134KHz Cooling by free air convection LED indicator for power on Low profile: 33mm thickness Model Number Output Volts Output Amps Ripple & Noise Load Reg Volt Tolerance Min Load TRIPLE OUTPUT TP75-A 5 Volts(DC) 7.0 Amps 100mVpk-pk ±3.0% ±3.0% 1.5~10Amps -5 Volts(DC) 0.6 Amps 100mVpk-pk ±8.0% ±8.0% 0~0.6Amps TP75-B 5 Volts(DC) 7.0 Amps 100mVpk-pk ±3.0% ±3.0% 1.5~10Amps -12 Volts(DC) 0.4 Amps 120mVpk-pk ±8.0% ±8.0% 0~0.6Amps TP75-C 5 Volts(DC) 6.0 Amps 100mVpk-pk ±3.0% ±3.0% 1.5~10Amps -15 Volts(DC) 0.5 Amps 120mVpk-pk ±8.0% ±8.0% 0~0.6Amps
75W Triple Output with PFC Function TP75 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage Range (Note 3) 90-264VAC / 127-370 Volts(DC) Frequency Range 47-63 Hz Inrush Current, typ: (cold start) 20 Amps @ 230VAC Input Current 1.5 Amps max @ 115VAC
0.8 Amps max @ 230VAC
Leakage current < 2mA / 240 VAC Power Factor @ FL PF > 0.95/230VAC >0.98/115VAC OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Line Regulation ±1.0% Load Regulation See Selection Chart Voltage Tolerance (Note 2) See Selection Chart Ripple/Noise (Note 1) See Selection Chart Hold Up Time @ FL 36mS Setup, Rise Time @ FL 800mS, 60mS Over Voltage Protection 5Volts(DC) only: 5.75~6.75Volts(DC) Shutdown o/p voltage, re-power Over Current Protection 105~150% rated ourtput power Hiccup mode, auto-recover DC Voltage Adjust 5Volts(DC) : 4.5~5.5Volts(DC) GENERAL SPECIFICATIONS Safety UL60950-1 TUV EN60950-1 approved Insulation Resistance ≥ 100MΩ / 500 Volts(DC) EMI Compliance to EN55022 (CISPR22) Class B Harmonic Current Compliance to EN61000-3-2,-3 Efficiency 70% typ. Isolation 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground 1min EMS Compliance to ENV50204, EN55024 light industry level, criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature -10°C to +60°C (See Derate Curve) Storage Temperature -20°C to +85°C, 10~95% RH Relative Humidity 20 to +90% RH non cond Temperature Coefficient ±0.03% / °C (0-50°C) MTBF 198.4KHrs min, MIL-HDBK-217F (25°C) Vibration 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters 179 x 99 x 33 Inches 7.05” x 3.90” x 1.30” Weight 22.93 oz (650g) NOTE 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regula- tion. 3. Derating may be needed under low input voltages. Please check the derating curve for more details. All specifications are typical at nominal input, full load, and 25°C unless other- wise noted Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
75W Triple Output with PFC Function TP75 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458
75W Triple Output with PFC Function TP75 series WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458