TP40DG_19 TOPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
www.gztoppower.com TEL:0086-20-82019000 EMAIL:sales2@gztoppower.com page 1 of 4 DESCRIPTION:: :: The rated output power of TP40DG converters is 40W,the outline dimensions is "50.8*50.8*12.7", 2:1,4:1 input voltage range ,the voltage range is 9V-18V, 9V-36V,18V-36V,36V-72V.The accuracy of the converter can reach ±1%,it can be widely used in telecommunications, railway transportation, instrument and etc. 40W 1.5KVDC Isolated Wide Input Voltage DC/DC Converters All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
40W output power 2:1,4:1 input voltage range Input under voltage protection 50.8mm*50.8mm*12.7mm standard package Fixed switching frequency Super capability with capacitive load Long term short-circuit protection Operating temperature: -40℃to 85℃ RoHs compliance SELECTION GUIDE Part Number Input Voltage Output Efficiency(Typ.) % voltage(VDC) Voltage(VDC) Current(A) Rated Range values TP40DG12S03 12(2:1) 9-18 3.3 8 85 TP40DG12S05 12(2:1) 9-18 5 8 83 TP40DG12S12 12(2:1) 9-18 12 3.33 86 TP40DG12S15 12(2:1) 9-18 15 2.67 86 TP40DG12S24 12(2:1) 9-18 24 1.67 85 TP40DG12D05 12(2:1) 9-18 ±5 ±4 83 TP40DG12D12 12(2:1) 9-18 ±12 ±1.67 86 TP40DG12D15 12(2:1) 9-18 ±15 ±1.33 86 TP40DG24S03 24(2:1) 18-36 3.3 8 85 TP40DG24S05 24(2:1) 18-36 5 8 84 TP40DG24S12 24(2:1) 18-36 12 3.33 87 TP40DG24S15 24(2:1) 18-36 15 2.67 87 TP40DG24S24 24(2:1) 18-36 24 1.67 86 TP40DG24D05 24(2:1) 18-36 ±5 ±4 83 TP40DG24D12 24(2:1) 18-36 ±12 ±1.67 86 TP40DG24D15 24(2:1) 18-36 ±15 ±1.33 86 TP40DG48S03 48(2:1) 36-72 3.3 8 85 TP40DG48S05 48(2:1) 36-72 5 8 84 TP40DG48S12 48(2:1) 36-72 12 3.33 87 TP40DG48S15 48(2:1) 36-72 15 2.67 87 TP40DG48S24 48(2:1) 36-72 24 1.67 86 TP40DG48D05 48(2:1) 36-72 ±5 ±4 83 TP40DG48D12 48(2:1) 36-72 ±12 ±1.67 86 TP40DG48D15 48(2:1) 36-72 ±15 ±1.33 86 TP40DG24S05W 24(4:1) 9-36 5 8 84 TP40DG24S12W 24(4:1) 9-36 12 3.33 87 TOPPOWER
www.gztoppower.com TEL:0086-20-82019000 EMAIL:sales2@gztoppower.com page 2 of 4 GENERAL CHARACTERISTICS parameter Test conditions Min Typ Max Units Isolation voltage Input to output 500 1500 VDC Insulation resistance Input to output 100M Ohm Seismic 10~55Hz 5 G MTBF MIL-HDBK-217F2 5x105 hrs Over-current protection mode All input range Burp, Automatic recovery Cooling Free air convection Case material Metal case OUTPUT CHARACTERISTICS parameter Test conditions Min Typ Max Units Voltage accuracy Io=0.1/elipsis1.0 x Ionom Vi=Vi rated ±1 % Line regulation Vimin≤Vi≤Vimax ±0.2 % Load regulation Io=0.1/elipsis1.0 x Ionom Vimin≤ Vi≤Vimax ±0.5 % Auxiliary voltage accuracy Main Load and auxiliary load differ 25%,the auxiliary circuit of the load with at least 25%, the main circuit with full load ±3 % Ripple and noise 20MHz bandwidth ±1 % Over-current protection Vimin≤Vi≤Vimax 120 % Output voltage trim range Vimin≤Vi≤Vimax 10 % Transient recovery time 25% load changes ±5 % Transient overshoot time 25% load changes 400 us Switch frequency Vimin≤Vi≤Vimax 300 KHz INPUT CHARACTERISTICS parameter Test conditions Min Typ Max Units Startup voltage The12V input module(9V-18V) 9.2 9.5 9.8 VDC Startup voltage The24V input module(18V-36V) 18 VDC Startup voltage The48Vinput module(36V-72V) 36 VDC Input under voltage protection The12V/24V input module(9V-18V,9V-36V) 8.5 VDC Input under voltage protection The24V input module(18V-36V) 17 VDC Input under voltage protection The48Vinput module(36V-72V) 35 VDC Startup time Output rise time from 5% to 100% 20 ms Remote control CTL Remote CTL-Vin Turn off Remote control CTL Remote CTL NC(The control level 12V-40V) Turn on ENVIRONMENT CHARACTERISTICS parameter Test conditions Min Typ Max Units Storage Humidity Non condensing 5 +95 % Operating Temperature Power derating (above 71℃ -40 +85 ℃ Storage Temperature -55 +125 ℃ Max. Case Temperature Operating Temperature curve range 105 ℃ Lead Temperature 1.5mm from case for 10 seconds 300 ℃ Cooling Free air convection /circle6 Module in every environment temperature rating, case temperature under shall not exceed the maximum case temperature level. TOPPOWER
www.gztoppower.com TEL:0086-20-82019000 EMAIL:sales2@gztoppower.com page 3 of 4 Units: mm Tolerance: ± 0.2mm MECHANICAL DIMENSIONS PIN CONNECTIONS Pin Single output Dual output 1 +Vin +Vin 2 -Vin -Vin
3 CTL CTL
4 TRM TRM
[4] / / 5 -Vout -Vout [5] / / 6 +Vout / (6) / COM [6] / / 7 / +Vout [7] / / MODEL SELECTION RECOMMEND CIRCUIT Single Output: + vin -vin Cin + V0 Cout -V0 DC-DC TP 40 D G 12 S 05 W W:4:1 Wide voltage input range Output voltage S: Single output D: Dual output Input Rated Voltage Package type DC-DC Output rated power Brand name 50.80 45.722.54 12.90 10.16 5.08 10.16 10.16 10.16 10.16 50.80 1.00Min4.60 (6) [7] (6) [5] [4] bottom view 12.70 TOPPOWER
www.gztoppower.com TEL:0086-20-82019000 EMAIL:sales2@gztoppower.com page 4 of 4 STEMPERATURE DERATING GR RECOMMEND CIRCUIT Dual Output: Trim application &Trim Resistance USING ATTENTIONS /circle6 Module will cause irreversible damage when in the state of the input reverse polarity. /circle6 Module will cause irreversible damage when in the long-term overload conditions. /circle6 Module will cause irreversible damage when out of the maximum input voltage range. +vin -vin Cin +V0 Cout1 -V0 DC-DC Cout2 COM +Vo Trim(Vadj) -Vo DC-DC R +Vo Trim(Vadj) -Vo R DC-DC /circle6 Add input capacitance Cin is helpful to improve the electromagnetic compatibility, recommend Cin use 47 uF-100uF of the electrolytic capacitors. /circle6 If the module connect to the digital circuits, please add the Cout、Cout1、Cout2. /circle6 If Cout, Cout1, Cout2 value is too high or lower ESR, it will cause the module instable, /circle6 The recommended value of Cout, Cout1, Cout2 should be 100 uF/A, the current here means the output current. Raise the output Voltage Down the output voltage /circle6 In dual and triple output modules, this application can just used in the main load(auxiliary road change together with the main load) TOPPOWER