Technical content
w w w . g z t o p p o w e r . c o m T E L :0086-20-62162688 EMAIL :sales2@gztoppower.com page 1 of 4 DESCRIPTION : The rated output power of TP40DG converters is 40W,the outline dimensions is "50.8*50.8*12.7", 2:1,4:1 input voltage range ,the voltage range is 9V-18V, 9V-36V,18V-36V,36V-72V.The accuracy of the converter can reach ±1%,it can be widely used in telecommunications, railway transportation, instrument and etc. 40W 1.5KVDC Isolated Wide Input Voltage DC/DC Converters All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
40W output power 2:1,4:1 input voltage range Input under voltage protection 50.8mm*50.8mm*12.7mm standard package Fixed switching frequency Super capability with capacitive load Long term short-circuit protection Operating temperature: -40℃to 85℃ RoHs compliance SELECTION GUIDE Part Number Input Voltage Output Efficiency(Typ.) % voltage(VDC) Voltage(VDC) Current(A) Rated Range values TP40DG12S03 12(2:1) 9-18 3.3 8 85 TP40DG12S05 12(2:1) 9-18 5 8 83 TP40DG12S12 12(2:1) 9-18 12 3.33 86 TP40DG12S15 12(2:1) 9-18 15 2.67 86 TP40DG12S24 12(2:1) 9-18 24 1.67 85 TP40DG12D05 12(2:1) 9-18 ±5 ±4 83 TP40DG12D12 12(2:1) 9-18 ±12 ±1.67 86 TP40DG12D15 12(2:1) 9-18 ±15 ±1.33 86 TP40DG24S03 24(2:1) 18-36 3.3 8 85 TP40DG24S05 24(2:1) 18-36 5 8 84 TP40DG24S12 24(2:1) 18-36 12 3.33 87 TP40DG24S15 24(2:1) 18-36 15 2.67 87 TP40DG24S24 24(2:1) 18-36 24 1.67 86 TP40DG24D05 24(2:1) 18-36 ±5 ±4 83 TP40DG24D12 24(2:1) 18-36 ±12 ±1.67 86 TP40DG24D15 24(2:1) 18-36 ±15 ±1.33 86 TP40DG48S03 48(2:1) 36-72 3.3 8 85 TP40DG48S05 48(2:1) 36-72 5 8 84 TP40DG48S12 48(2:1) 36-72 12 3.33 87 TP40DG48S15 48(2:1) 36-72 15 2.67 87 TP40DG48S24 48(2:1) 36-72 24 1.67 86 TP40DG48D05 48(2:1) 36-72 ±5 ±4 83 TP40DG48D12 48(2:1) 36-72 ±12 ±1.67 86 TP40DG48D15 48(2:1) 36-72 ±15 ±1.33 86 TP40DG24S05W 24(4:1) 9-36 5 8 84 TP40DG24S12W 24(4:1) 9-36 12 3.33 87 TOPPOWER
w w w . g z t o p p o w e r . c o m T E L :0086-20-62162688 EMAIL :sales2@gztoppower.com page 2 of 4 GENERAL CHARACTERISTICS parameter Test conditions Min Typ Max Units Isolation voltage Input to output 500 1500 VDC Insulation resistance Input to output 100M Ohm Seismic 1 0 ~ 5 5 H z 5 G MTBF MIL-HDBK-217F2 5x105 hrs Over-current protection mode All input range Burp, Automatic recovery Cooling Free air convection Case material Metal case OUTPUT CHARACTERISTICS parameter Test conditions Min Typ Max Units Voltage accuracy Io=0.1…1.0 x Ionom Vi=Vi rated ±1 % Line regulation Vimin≤Vi≤Vimax ±0.2 % Load regulation Io=0.1…1.0 x Ionom Vimin ≤ Vi≤Vimax ±0.5 % Auxiliary voltage accuracy Main Load and auxiliary load differ 25%,the auxiliary circuit of the load with at least 25%, the main circuit with full load ±3 % Ripple and noise 20MHz bandwidth ±1 % Over-current protection Vimin≤Vi≤Vimax 120 % Output voltage trim range Vimin≤Vi≤Vimax 10 % Transient recovery time 25% load changes ±5 % Transient overshoot time 25% load changes 400 us Switch frequency Vimin≤Vi≤Vimax 300 KHz INPUT CHARACTERISTICS parameter Test conditions Min Typ Max Units Startup voltage The12V input module(9V-18V) 9.2 9.5 9.8 VDC Startup voltage The24V input module(18V-36V) 18 VDC Startup voltage The48Vinput module(36V-72V) 36 VDC Input under voltage protection The12V/24V input module(9V-18V,9V-36V) 8.5 VDC Input under voltage protection The24V input module(18V-36V) 17 VDC Input under voltage protection The48Vinput module(36V-72V) 35 VDC Startup time Output rise time from 5% to 100% 20 ms Remote control CTL Remote CTL-Vin Turn off Remote control CTL Remote CTL NC(The control level 12V-40V) Turn on ENVIRONMENT CHARACTERISTICS parameter Test conditions Min Typ Max Units Storage Humidity Non condensing 5 +95 % Operating Temperature Power derating (above 71℃ -40 +85 ℃ Storage Temperature -55 +125 ℃ Max. Case Temperature Operating Temperature curve range 105 ℃ Lead Temperature 1.5mm from case for 10 seconds 300 ℃ Cooling Free air convection Module in every environment temperature rating, case temperature under shall not exceed the maximum case temperature level. TOPPOWER
w w w . g z t o p p o w e r . c o m T E L :0086-20-62162688 EMAIL :sales2@gztoppower.com page 3 of 4 Units: mm Tolerance: ± 0.2mm MECHANICAL DIMENSIONS PIN CONNECTIONS Pin Single output Dual output 1 +Vin +Vin 2 -Vin -Vin
3 CTL CTL
4 TRM TRM
[4] / / 5 -Vout -Vout [5] / / 6 +Vout / (6) / COM [6] / / 7 / +Vout [7] / / MODEL SELECTION RECOMMEND CIRCUIT Single Output: +vin -vin Cin +V0 Cout -V0 DC-DC TP 40 D G 12 S 05 W W:4:1 Wide voltage input range Output voltage S: Single output D: Dual output Input Rated Voltage Package type DC-DC Output rated power Brand name 50.80 45.722.54 12.90 10.16 5.08 10.16 10.16 10.16 10.16 50.80 1.00Min4.60 (6) [7] (6) [5] [4] bottom view 12.70 TOPPOWER
w w w . g z t o p p o w e r . c o m T E L :0086-20-62162688 EMAIL :sales2@gztoppower.com page 4 of 4 STEMPERATURE DERATING GR RECOMMEND CIRCUIT Dual Output: Trim application &Trim Resistance USING ATTENTIONS Module will cause irreversible damage when in the state of the input reverse polarity. Module will cause irreversible damage when in the long-term overload conditions. Module will cause irreversible damage when out of the maximum input voltage range. +vin -vin Cin +V0 Cout1 -V0 DC-DC Cout2 COM +Vo Trim(Vadj) -Vo DC-DC R +Vo Trim(Vadj) -Vo R DC-DC Add input capacitance Cin is helpful to improve the electromagnetic compatibility, recommend Cin use 47 uF-100uF of the electrolytic capacitors. If the module connect to the digital circuits, please add the Cout 、Cout1、Cout2. If Cout, Cout1, Cout2 value is too high or lower ESR, it will cause the module instable, The recommended value of Cout, Cout1, Cout2 should be 100 uF/A, the current here means the output current. Raise the output Voltage Down the output voltage In dual and triple output modules, this application can just used in the main load(auxiliary road change together with the mai n load) TOPPOWER