TP30AU TOPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
www.gztoppower.com TEL:0086-20-82019000 Email:sales2@gztoppower.com page 1 of 3 DESCRIPTION: The rated output power ofTP30AU converters is 30W with wide input voltage range, for both AC input and DC input application. High reliability, precision, large power density, ultra-small size, no external heat sink required, stable output voltage and etc, with over current protection, EMI filter circuit, the rectifier filter circuit, 3000V isolation voltage, short circuit, overload, internal thermal protection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control and other electronic systems. 30W 3KVAC Isolation Wide Input AC/DC Converters All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation voltage Input / Output 1 minute, leakage current 2mA 3000 VAC Seismic 10~55Hz 5 G Over-current protection Full input range Burp,Automatic recovery Cooling Free air convection Case material Flame-retardant plastic
FEATURES
Universal input voltage range Both for AC and DC input voltage Wide input voltage:2:1 and 4:1 Fixed switching frequency Overheat protection Over current protection Short circuit protection RoHS compliant Operating temperature: -40℃to 70℃ SELECTION GUIDE Part Number Input Voltage Output Efficiency (Typ. ) Recommend output external capacitor Rated Range values Voltage (VDC) Current (VAC) TP30AU220S05W 220(4:1) 90-277 5 6.0 76 0.1uF/25V 2200uF/16V / TP30AU220S12W 220(4:1) 90-277 12 2.5 77 0.1uF/25V 680uF/25V / TP30AU220S15W 220(4:1) 90-277 15 2 78 0.1uF/25V 680uF/25V / TP30AU220S24W 220(4:1) 90-277 24 1.25 78 0.1uF/25V 470uF/35V / TP30AU220D05W 220(4:1) 90-277 ±5 ±3 77 0.1uF/25V 2200uF/16V 2200uF/16V TP30AU220D12W 220(4:1) 90-277 ±12 ±1.25 79 0.1uF/25V 680uF/25V 680uF/25V TP30AU220D15W 220(4:1) 90-277 ±15 ±1 79 0.1uF/25V 680uF/25V 680uF/25V TP30AU220D05P05W 220(4:1) 90-277 +5/+5 5.2/0.8 75 0.1uF/25V 1000uF/16V 1000uF/16V TP30AU220D05P12W 220(4:1) 90-277 +5/+12 4.0/0.8 76 0.1uF/25V 1000uF/16V 470uF/25V TP30AU220D05P15W 220(4:1) 90-277 +5/+15 3.6/0.8 76 0.1uF/25V 1000uF/16V 470uF/25V TP30AU220D05P24W 220(4:1) 90-277 +5/+24 3.6/0.8 76 0.1uF/25V 1000uF/16V 220uF/35V TP30AU220T05D12W 220(4:1) 90-277 +5/±12 4.4/±0.34 75 0.1uF/25V 2200uF/16V 220uF/25V TP30AU220T05D15W 220(4:1) 90-277 +5/±15 4.4/±0.27 76 0.1uF/25V 2200uF/16V 220uF/25V TP30AU220T05D24W 220(4:1) 90-277 +5/±24 4.4/±0.17 77 0.1uF/25V 2200uF/16V 200uF/35V INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Startup voltage VAC Input 90 220 277 VAC Startup voltage VDC Input 120 380 VAC Start rising time Non-capacitive load 20 ms TOPPOWER
www.gztoppower.com TEL:0086-20-82019000 Email:sales2@gztoppower.com page 2 of 3 OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage accuracy Io=0.1/elipsis1.0 x Ionom Vi=Vi rated ±3 % ±5 % Line regulation Vimin≤Vi≤Vimax ±0.5 % Load regulation Io=0.1/elipsis1.0 x Ionom Vimin≤ Vi≤Vimax ±1 % Auxiliary voltage accuracy Main Load and auxiliary load differ 25%,the auxiliary circuit of the load with at least 25%, the main circuit with the full load ±3 % Ripple and noise 20MHz bandwidth ±1 % Over-current protection Vimin≤Vi≤Vimax 120 % Switch frequency Vimin≤Vi≤Vimax 100 Hz ENVIRONMENT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operating temperature industrial-class -40 +70 ℃ Maximum case temperature industrial-class +95 ℃ Storage temperature Industry-class -40 +105 ℃ Relative humidity No condensation 5 90 RH(% ) Temperature coefficient ±0.02 %/ ℃ MECHANICAL DIMENSIONS PIN CONNECTIONS Pin Single output Dual output (Com) Dual output (NC) Triple output
1 FG FG FG FG
2 N N N N
3 L L L L
(4) / / -V01 -V01 5 / / +V01 +V01 6 / COM / / (6) / / / -V02 7 / / -V02 / (7) / / / COM 8 +V0 +V0 / / (8 ) / / +V02 +V02 unit: mm tolerance of PIN diameter:±0.10MM Unmarked tolerances :±0.50MM Case temperature shall not exceed the maximum case temperature 48.00 1.00 23.5 6.00±2.00 20.00 20.00 4 (4) 6 (6) 7 (7) 8 (8) 5.75 4.00 62.00 23.00 70.00 bottom view TOPPOWER
www.gztoppower.com TEL:0086-20-82019000 Email:sales2@gztoppower.com page 3 of 3 MODEL SELECTION RECOMMEND CIRCUIT C1, C2, C3, C4, C5, C6 capacitor values refer to parameter table USING ATTENTIONS /circle6 Module will cause irreversible damage when it in the long-term overload state. /circle6 Module will cause irreversible damage when it out of the state maximum input voltage range TP 30 A U 220 D 05 W W:4:1 Wide voltage input range Main (auxiliary) output voltage S:single output, D:Dual output Rated input voltage Package type AC-DC Rated output power Brand name TP 30 A U 220 T 05 D 12 W W:4:1 wide voltage input range Auxiliary output voltage D: Auxiliary is dual output Main output voltage S:single output, D:Dual output T:Triple Output Rated input voltage Package type AC-DC Rated output power Brand name W:4:1 Wide voltage input range Auxiliary Output Voltage P: Auxiliary is positive output voltage Main output voltage S:single output, D:Dual output T:Triple OutpuS: Rated input voltage Package type AC-DC Rated output power Brand name TP 30 A U 220 T 05 P 12 W Single O utput AC-DC FUSE C1 C2 -V0 +V 0 FG N L Triple output FUSE +V01 -V01 +V02 COM -V02 C1 C4 C2 C5 C3 C6 FG N L AC-DC Dual Output(COM) AC-DC FUSE C1 +V0 -V0 COM FG N L AC-DC Dual Output(not COM) FUSE C1 C3 C2 C3 +V01 -V01 +V02 -V02 FG N L TOPPOWER