www.gztoppower.con TEL:0086-20-82019000 Email:sales2@gztoppower.com Page 1 / 3 DESCRIPTION : The rated output power of TP05AC series is 5W with wide input voltage range, for both AC input and DC input application. High reliability, precision, large power density, ultra-small size, no external heat sink required, stable output voltage and etc, with over current protection, EMI filter circuit, the rectifier filter circuit, 4000V isolation voltage, short circuit, overload, internal thermal protection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control and other electronic systems. 5W 4KV Isolation Wide Input AC/DC Converters All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation voltage Input / Output 1 minute, leakage current 2mA 4000 VAC Input Frequency 10~55Hz 47 63 HZ Over current protection Full input range Auto recovery Cooling Free air convection Case material Flame-retardant plastic OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Voltage accuracy ±2 % Line regulation Full load ±0.5 % Load regulation 10%~100% load ±1 % Standby power consumption 0.3 W Over current protection ≥110%Io , self-recovery Over voltage protection Over-voltage shutdown output Ripple and noise 20MHz bandwidth 50 100 mv Short-circuit protection Hiccup-type, sustainable short-circuit, self-recovery Switch frequency 140 Hz Power-down hold time 110VAC 12 ms 230VAC 80 ms

FEATURES

Universal input voltage range Both for AC and DC input voltage Wide input voltage: 4:1 Fixed switching frequency Overheat protection Over current protection Short circuit protection RoHS compliant Operating temperature :-25 ℃ to 70 ℃ Part Number Input Voltage Output Efficiency (Typ. ) Rated Voltage (VDC) Current (A) (VAC) (VDC) TP05AC220S05W 85-300 110-370 5 1.0 69 TP05AC220S09W 85-300 110-370 9 0.55 73 TP05AC220S12W 85-300 110-370 12 0.42 75 TP05AC220S15W 85-300 110-370 15 0.33 76 TP05AC220S24W 85-300 110-370 24 0.23 78 INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Startup voltage VAC In module(85V-300V) 85 220 300 VAC Startup voltage VDC In module(110V-370V) 110 220 375 VDC External fuse recommended value(wiring, rail type Package has included fuse) Fuse must be connected, recommended 1A / 250V slow-off type

www.gztoppower.con TEL:0086-20-82019000 Email:sales2@gztoppower.com Page 2 / 3 MODEL SELECTION ENVIRONMENT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Operating temperature industrial-class -40 +70 ℃ Maximum case temperature industrial-class +95 ℃ Storage temperature Industry-class -40 +85 ℃ Relative humidity No condensation 85 RH(% ) Temperature coefficient ±0.02 %/℃ Power derating +55 ℃~+70 ℃ 2.0 %/ ℃ Power derating +0 ℃~-25 ℃ 2.0 %/ ℃ MTBF MIL-HDBK-217F@25 ℃>300,000 h MECHANICAL DIMENSIONS Pin Single Output 1 N 2 L 3 +V0 4 -V0 * Pin not fitted on single output variants Units:mm Tolerance:±0.2mm /circle6 Case temperature shall not exceed the maximum case temperature. W:4:1 Wide voltage input range Main (auxiliary) output voltage S:single output, D:Dual output Rated input voltage Package type AC-DC Rated output power Brand name

www.gztoppower.con TEL:0086-20-82019000 Email:sales2@gztoppower.com Page 3 / 3 EMC EMC EMC EMC CHARA CHARA CHARA CHARATERISTICS TERISTICS TERISTICS TERISTICS EMI Conducted harassment CISPR22/EN55022, CLASS B EMI Radiation harassment CISPR22/EN55022, CLASS B EMS Electrostatic discharge IEC/EN61000-4-2 ±6KV/8KV perf. Criteria B EMS Radiation immunity IEC/EN61000-4-3 10V/m perf. Criteria A EMS Impulse group immunity IEC/EN61000-4-4 ± 2kV perf. Criteria B EMS Impulse group immunity IEC/EN61000-4-4 ± 4kV (see recommended circuit ) perf. Criteria B EMS Surge Immunity IEC/EN61000-4-5 ±1KV perf. Criteria B EMS Surge Immunity IEC/EN61000-4-5 ±2KV/±4KV (see recommended circuit ) perf. Criteria B EMS Conducted disturbance immunity IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A EMS Power frequency magnetic field immunity IEC/EN61000-4-8 10A/m perf. Criteria A EMS Voltage dips, drops and short interrupt immunity IEC/EN61000-4-11 0%-70% perf. Criteria B RECOMMEND CIRCUIT 1.the typical application circuit The output filter capacitor C2, the proposed use of high-frequency low-resistance electrolytic capacitors, capacity and flow of current refer to the manufacturers to provide technical specifications. The output capacitor withstanding voltage derating factor is greater than 80%. C1 is a ceramic capacitor to remove high frequency noise. Recommended external N C thermistor, model: 12D-5. Recommended external MOV varistor, type: 14D561K. 2. EMC solutions - recommended circuit EMC Solutions - Recommended Circuit PCB Layout Note: safety regulations and the width of the proposed line: line width ≥ 3mm, line distance ≥ 6mm, line distance ≥ 6mm