Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved www.rakonxpress.com Table of Contents TMX U386 SAW Filter datasheet 3.8 x 3.8 x 1.5 mm, SMD

SAW Bandpass Filters | Wireless Communications Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved Page 1 of 6 www.rakonxpress.com

Features

Parameter Min. Typ. Max. Unit Storage temperature range (Tstg) -45 90 °C Operating temperature range (TA) -40 85 °C DC permissive voltage 0 V Maximum pulse input power 15 dBm Frequency and Electrical Characteristics (Reference temperature @ 25°C) Parameter Min. Typ.1 Max. Unit Center frequency (fC) 433.92 MHz Bandwidth (BW, passband width) 1.58 MHz Insertion loss (IL, 433.13 – 434.71 MHz) 2.8 3.9 dB Amplitude ripple (433.13 – 434.71 MHz) 0.3 1.0 dB Relative attenuation (relative to IL) From 10.00 to 350.0 MHz From 350.0 to 393.0 MHz From 393.0 to 408.0 MHz From 408.0 to 415.0 MHz From 415.0 to 425.0 MHz From 443.5 to 454.0 MHz From 454.0 to 475.0 MHz From 475.0 to 650.0 MHz From 650.0 to 1000.0 MHz dB dB dB dB dB dB dB dB dB Temperature coefficient of frequency -30.0 ppm/K Source impedance2 (Single ended) 50 Ω Load impedance2 (Single ended) 50 Ω

1 Typical values are nominal performances at room temperature

2 No external matching is required

Features Applications 3.8 x 3.8 x 1.5 mm  433.92 MHz center frequency  Ceramic package for Surface Mounted Technology  Low Loss: 2.8 dB typical value within PassBand Width 433.13 to 434.71 MHz  Maximum pulse power: 15 dBm  No matching network required for operation at 50 Ω  Remote control - RF  Wireless applications: o Home appliances o Security systems

SAW Bandpass Filters | Wireless Communications Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved Page 2 of 6 www.rakonxpress.com Model Outline, Pin Connection and Marking Test Circuit Pin Connections

2 Input

1, 3 Input Ground

6 Output

5,7 Output Ground 4, 8 To be grounded Code Dimensions (mm) A 1.0 B 1.27 C 0.6 D 1.3 (1.5 max.) E 3.8 F 3.8 Marking Note Line 1 U386 RakonXpress designation Line 2 U63601 U = Production code 6 = The last digit of year 2016 36 = Week 36 of the year 01= Internal code (Wafer batch) Line 3 • • = Identify black dot 50 Ω / 50 Ω Configuration TOP VIEW FRONT VIEW BOTTOM VIEW From 50Ω source To 50Ω load Input Single, 50Ω Output Single, 50Ω Unit: mm

SAW Bandpass Filters | Wireless Communications Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved Page 3 of 6 www.rakonxpress.com Frequency Characteristics TYPICAL S21 RESPONSE

SAW Bandpass Filters | Wireless Communications Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved Page 4 of 6 www.rakonxpress.com Recommended Reflow Soldering Profile NOTE:

  • The components shall remain within the electrical specifications after it soldered on the 1mm thickness PCB board and dipped in the solder at 260 ± 5°C during 10 ± 1 seconds.
  • The components shall remain within the electrical specifications after it soldered by electric iron, solder at 350 ± 10 °C during 3~4 seconds. Recovery time: 2 ± 0.5 hour.
  • Ultrasonic cleaning may cause deterioration and destruction of the component. Please avoid ultrasonic cleaning.
  • Only leads of components may be soldered. Please avoid soldering another part of the component. 100 120 140 160 180 200 220 240 260 280 100 120 140 160 180 200 220 240 260 280 300 320 340 360 Time (Sec) Temp ( Deg C)

SAW Bandpass Filters | Wireless Communications Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved Page 5 of 6 www.rakonxpress.com Tape and Reel Specifications TAPE DETAILS: REEL DETAILS: Parameter Code Dimension Tolerance Height of component hole A 4.1 ± 0.1 Width of component hole B 4.1 ± 0.1 Diameter of sprocket hole D0 Φ 1.5 ± 0.1 Diameter of feed hole D1 Φ 1.5 min Pitch of sprocket hole P0 4.0 ± 0.1 Length from hole center to component center P1 8.0 ± 0.1 Length from Pocket hole center to sprocket hole center P2 4.0 ± 0.1 Width of carrier tape W 12.0 ± 0.3 Width of adhesive tape F 5.5 ± 0.3 Gap of hold down tape and carrier tape E 1.75 ± 0.1 Thickness of Ebossed tape sheet t1 0.31 max Thickness of Ebossed tape t2 1.7 max Tape running direction NOTE:  Unit: mm  Standard Packing Quantity (SPQ) is 1000 pieces/ reel

SAW Bandpass Filters | Wireless Communications Issue: Rev 3, 9 November 2022 Specifications are subject to change without notice Copyright © 2016 to 2022 Rakon Limited. All rights reserved Page 6 of 6 www.rakonxpress.com Reliability Test Parameter Test condition / Description Thermal Shock The components shall remain within the electrical specifications after being kept at the condition of heat cycle conditions: TA=-40°C ±3°C, TB=85°C ±2°C, t1=t2=30min, switch time ≤3min & cycle time: 100 times, recovery time: 2h±0.5h. Temperature Storage High Temperature Storage: The components shall remain within the electrical specifications after being kept at the 85°C ±2°C for 500 hours, recovery time: 2h ±0.5h. Low Temperature Storage: The components shall remain within the electrical specifications after being kept at the -40°C ±3°C for 500 hours, recovery time: 2h ±0.5h. Humidity test The components shall remain within the electrical specifications after being kept at the condition of ambient temperature 60°C ±2°C, and 90~95% RH for 500 hours. Drop test The components shall remain within the electrical specifications after random free drops 10 times from height of 1.0 meter onto concrete floor, and the specimens shall meet the electrical specifications. Vibration Fatigue The components shall remain within the electrical specifications after loaded vibration at 10~55Hz, amplitude 1.5mm, X, Y, Z, direction, during 2 hours. Mechanical Shock The components shall remain within the electrical specifications after 1000 shocks, acceleration 392 m/s² , duration 6ms. Note As a result of the particularity of inner structure of SAW products, the components can easily be breakdown by electrostatic shock; so it’s mandatory to pay attention to ESD protect during the tests.