FEATURES
DESCRIPTION
APPLICATIONS
T emp. Sensor /c68/c83 A/D Converter OSC Control Logic Serial Interface Config. and□T emp. Register TMP102 T emperature SCL 1 4ALERT SDA GND 2 5 V+ ADD0 TMP102 SBOS397 AUGUST 2007 Low Power Digital Temperature Sensor With SMBus /Two-Wire Serial Interface in SOT563 TINY SOT563 PACKAGE The TMP102 is a two-wire, serial output temperature sensor available in a tiny SOT563 package. ACCURACY: 0.5 C C to +85 Requiring no external components, the TMP102 is LOW QUIESCENT CURRENT: capable of reading temperatures to a resolution of μ A Active (max) 0.0625 μ A Shutdown (max) The TMP102 RANGE: 1.4V to 3.6V compatibility, and allows up to four devices on one RESOLUTION: Bits bus. It also function. DIGITAL OUTPUT: Two-Wire Serial Interface The TMP102 is ideal for extended temperature measurement in a variety of communication, computer, consumer, environmental, industrial, and PORTABLE AND BATTERY-POWERED instrumentation applications. The device is specified a temperature range of C to +125 POWER-SUPPLY TEMPERATURE MONITORING COMPUTER PERIPHERAL THERMAL PROTECTION NOTEBOOK COMPUTERS BATTERY MANAGEMENT OFFICE MACHINES THERMOSTAT CONTROLS ELECTROMECHANICAL DEVICE TEMPERATURES GENERAL TEMPERATURE MEASUREMENTS: Industrial Controls Test Equipment Medical Instrumentations Please be aware that an important notice concerning availability, standard warranty, and use in critical sheet. SMBus is a trademark of Intel, Inc. All other trademarks are the property of their respective owners. PRODUCTION DATA information is current as of publication date. Copyright 2007, Texas Instruments Incorporated Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
www.ti.com ABSOLUTE MAXIMUM RATINGS (1) PIN CONFIGURATION SDA ADD0 SCL GND ALERT CBZ TMP102 SBOS397 AUGUST 2007 This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. ORDERING INFORMATION (1) PRODUCT PACKAGE-LEAD PACKAGE DESIGNATOR PACKAGE MARKING TMP102 SOT563 DRL CBZ (1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI web site at www.ti.com PARAMETER TMP102 UNIT Supply Voltage 3.6 V Input Voltage (2) 0.5 to +3.6 V Operating Temperature to +150 C Storage Temperature to +150 C Junction Temperature +150 C Human Body Model (HBM) 2000 V ESD Rating Charged Device Model (CDM) 1000 V Machine Model (MM) 200 V (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not supported. (2) Input voltage rating applies to all TMP102 input voltages. DRL Package SOT563 Top View Submit Documentation Feedback
www.ti.com ELECTRICAL CHARACTERISTICS TMP102 SBOS397 AUGUST 2007 At T A +25 C and V S +1.4V to +3.6V, unless otherwise noted. TMP102 PARAMETER CONDITIONS MIN TYP MAX UNIT TEMPERATURE INPUT Range +125 C Accuracy (Temperature Error) C to +85 C 0.5 C C to +125 C C vs Supply 0.2 0.5 C/V Resolution 0.0625 C DIGITAL INPUT/OUTPUT Input Logic Levels: V IH 0.7 (V+) 3.6 V V IL 0.5 0.3 (V+) V Input Current I IN V IN 3.6V μ A Output Logic Levels: V OL SDA 2V, I OL 3mA 0.4 V 2V, I OL 3mA 0.2 (V+) V V OL ALERT 2V, I OL 3mA 0.4 V 2V, I OL 3mA 0.2 (V+) V Resolution Bit Conversion Time ms Conversion Modes CR1 CR0 0.25 Conv/s CR1 CR0 Conv/s CR1 CR0 (default) Conv/s CR1 CR0 Conv/s Timeout Time ms POWER SUPPLY Operating Supply Range +1.4 +3.6 V Quiescent Current I Q Serial Bus Inactive, CR1 CR0 (default) μ A Serial Bus Active, SCL Frequency 400kHz μ A Serial Bus Active, SCL Frequency 3.4MHz μ A Shutdown Current I SD Serial Bus Inactive 0.5 μ A Serial Bus Active, SCL Frequency 400kHz μ A Serial Bus Active, SCL Frequency 3.4MHz μ A TEMPERATURE RANGE Specified Range +125 C Operating Range +150 C Thermal Resistance, SOT563 θ JA 142 C/W Submit Documentation Feedback
www.ti.com TYPICAL CHARACTERISTICS T emperature□( C)/c176 /c45 60 /c45 20 40 60 140 160 I ( /c109A) Q 3.6V□Supply /c45 40 0 20 80 100 120 1.4V□Supply T emperature□( C)/c176 /c45 60 /c45 40 0 40 140 160 I ( /c109A) SD 3.6V□Supply 1.4V□Supply /c45 20 20 60 80 100 120 T emperature□( C)/c176 /c45 60 /c45 20 40 60 140 160 Conversion□Time□(ms) 3.6V□Supply 1.4V□Supply /c45 40 20 0 80 100 120 100 Bus□Frequency□(Hz) 1k 10k 100k 1M 10M I ( A) /c109 Q /c45 /c176 55 C+25 C/c176 +125 C/c176 2.0 1.5 1.0 0.5 /c45 0.5 /c45 1.0 /c45 1.5 /c45 2.0 T emperature□( C)/c176 /c45 60 /c45 40 40 60 140 160 T emperature□Error□( C) /c176 /c45 20 200 80 100 120 T emperature□Error□( C)/c176 Population TMP102 SBOS397 AUGUST 2007 At T A +25 C and 3.3V, unless otherwise noted. QUIESCENT CURRENT vs TEMPERATURE Conversions per Second) SHUTDOWN CURRENT vs TEMPERATURE Figure Figure QUIESCENT CURRENT vs BUS FREQUENCY CONVERSION TIME vs TEMPERATURE (Temperature at 3.3V Supply) Figure Figure TEMPERATURE ERROR vs TEMPERATURE TEMPERATURE ERROR AT +25 C Figure Figure Submit Documentation Feedback
www.ti.com APPLICATION INFORMATION POINTER REGISTER TMP102 0.01/c109F GND
3 ALERT
(Output)
4 ADD01SCL
NOTE:□SCL,□SDA,□and□ALERT pins□require□pull-up□resistors. I/O Control Interface SCL SDA T emperature Register Configuration Register TLOW Register THIGH Register Pointer Register TMP102 SBOS397 AUGUST 2007 The TMP102 is a digital temperature sensor that is optimal for thermal-management and thermal- Figure shows the internal register structure of the protection applications. The TMP102 is two-wire- and TMP102. The 8-bit Pointer Register of the device is SMBus interface-compatible, and is specified over a used to address a given data register. The Pointer temperature range of C to +125 Register uses the two LSBs (see Table to identify which of the data registers should respond to Pull-up resistors are required on SCL, SDA, and a read or write command. Table identifies the bits ALERT. A 0.01 μ F bypass capacitor is recommended, of the Pointer Register byte. During a write as shown in Figure command, through must always be '0'. Table describes the pointer address of the registers available in the TMP102. Power-up reset value of P1/P0 is '00'. By default, the TMP102 reads the temperature on power-up. Figure Typical Connections The temperature sensor in the TMP102 is the chip itself. Thermal paths run through the package leads, as well as the plastic package. The lower thermal resistance of metal causes the leads to provide the primary thermal path. To maintain accuracy in measurement, care should be taken to isolate the package and leads from ambient Table Pointer Register Byte air temperature. A thermally-conductive adhesive is helpful in achieving accurate surface temperature measurement. Register Bits Table Pointer Addresses REGISTER Temperature Register (Read Only) Configuration Register (Read/Write) T LOW Register (Read/Write) T HIGH Register (Read/Write) Submit Documentation Feedback
www.ti.com TEMPERATURE REGISTER TMP102 SBOS397 AUGUST 2007 complete. Bit of byte indicates Normal mode (EM bit '0') or Extended mode (EM bit '1') and The Temperature Register of the TMP102 is can be used to distinguish between the two configured as a 12-bit, read-only register temperature register data formats. The unused bits in (Configuration Register EM bit '0', see the the Temperature Register always read '0'. Extended Mode section), or as a 13-bit, read-only register (Configuration Register EM bit '1') that Table Byte of Temperature Register (1) stores the output of the most recent conversion. Two bytes must be read to obtain data, and are described in Table and Table Note that byte is the most T11 T10 significant byte, followed by byte the least (T12) (T11) (T10) (T9) (T8) (T7) (T6) (T5) significant byte. The first bits (13 bits in Extended (1) Extended mode 13-bit configuration shown in parenthesis. mode) are used to indicate temperature. The least significant byte does not have to be read if that Table Byte of Temperature Register (1) information is not needed. The data format for temperature is summarized in Table and Table One LSB equals 0.0625 Negative numbers are represented in binary two's complement format. (T4) (T3) (T2) (T1) (T0) (0) (0) (1) Following power-up or reset, the Temperature (1) Extended mode 13-bit configuration shown in parenthesis. Register will read C until the first conversion is Table 12-Bit Temperature Data Format (1) TEMPERATURE DIGITAL OUTPUT (BINARY) HEX 128 0111 1111 1111 7FF 127.9375 0111 1111 1111 7FF 100 0110 0100 0000 640 0101 0000 0000 500 0100 1011 0000 4B0 0011 0010 0000 320 0001 1001 0000 190 0.25 0000 0000 0100 004 0000 0000 0000 000 0.25 1111 1111 1100 FFC 1110 0111 0000 E70 1100 1001 0000 C90 (1) The resolution for the Temp ADC in Internal Temperature mode is 0.0625 C/count. For positive temperatures (for example, +50 C): Two's complement is not performed on positive numbers. Therefore, simply convert the number to binary code with the 12-bit, left-justified format, and MSB to denote a positive sign. Example: (+50 C)/(0.0625 C/count) 800 320h 0011 0010 0000 For negative temperatures (for example, C): Generate the Two's Complement of a negative number by complementing the absolute value binary number and adding Denote a negative number with MSB Example: C|)/(0.0625 C/count) 400 190h 0001 1001 0000 Two's complement format: 1110 0110 1111 1110 0111 0000 Submit Documentation Feedback
www.ti.com CONFIGURATION REGISTER ALERT (AL Bit) CONVERSION RATE EXTENDED MODE (EM) TMP102 SBOS397 AUGUST 2007 Table 13-Bit Temperature Data Format TEMPERATURE DIGITAL OUTPUT (BINARY) HEX 150 1001 0110 0000 0960 128 1000 0000 0000 0800 127.9375 0111 1111 1111 07FF 100 0110 0100 0000 0640 0101 0000 0000 0500 0100 1011 0000 04B0 0011 0010 0000 0320 0001 1001 0000 0190 0.25 0000 0000 0100 0004 0000 0000 0000 0000 0.25 1111 1111 1100 1FFC 1110 0111 0000 1E70 1100 1001 0000 1C90 The Configuration Register is a 16-bit read/write The AL bit is a read-only function. Reading the AL bit register used to store bits that control the operational will provide information about the comparator mode modes of the temperature sensor. Read/write status. The state of the POL bit inverts the polarity of operations are performed MSB first. The format and data returned from the AL bit. For POL the AL power-up/reset value of the Configuration Register is bit will read as '1' until the temperature equals or shown in Table For compatability, the first byte exceeds T HIGH for the programmed number of corresponds to the Configuration Register in the consecutive faults, causing the AL bit to read as '0'. TMP75 and TMP275 All registers are updated byte The AL bit will continue to read as '0' until the by byte. temperature falls below T LOW for the programmed number of consecutive faults, when it will again read Table Configuration and Power-Up/Reset as '1'. The status of the TM bit does not affect the Format status of the AL bit. BYTE OS POL TM SD The conversion rate bits, CR1 and CR0, configure the TMP102 for conversion rates of 8Hz, 4Hz, 1Hz, CR1 CR0 AL EM or 0.25Hz. The default rate is 4Hz. The TMP102 has a typical conversion time of 26ms. To achieve different conversion rates, the TMP102 makes a conversion and after that powers down and waits for the appropriate delay set by CR1 and CR0. Table The Extended mode bit configures the device for shows the settings for CR1 and CR0. Normal mode operation (EM or Extended mode operation (EM 1). In Normal mode, the Table Conversion Rate Settings Temperature Register and high- and low-limit CR1 CR0 CONVERSION RATE registers use a 12-bit data format. Normal mode is used to make the TMP102 compatible with the 0.25Hz TMP75 1Hz Extended mode (EM allows measurement of 4Hz (default) temperatures above +128 C by configuring the 8Hz Temperature Register, and high- and low-limit registers, for 13-bit data format. Submit Documentation Feedback
www.ti.com Startup Start□of Conversion Delay(1) 26ms 26ms Measured T emperature THIGH TLOW TMP102 ALERT□PIN (Comparator□Mode) POL□=□0 TMP102 ALERT□PIN (Interrupt□Mode) POL□=□0 TMP102 ALERT□PIN (Comparator□Mode) POL□=□1 TMP102 ALERT□PIN (Interrupt□Mode) POL□=□1 Read Read Time Read SHUTDOWN MODE (SD) FAULT QUEUE (F1/F0) THERMOSTAT MODE (TM) POLARITY (POL) TMP102 SBOS397 AUGUST 2007 After power-up or general-call reset, the TMP102 immediately starts a conversion, as shown in Figure The first result is available after 26ms (typical). The active quiescent current during conversion is μ A (typical at +27 C). The quiescent current during delay is 2.2 μ A (typical at +27 C). Figure Conversion Start Figure 10. Output Transfer Function Diagrams The Shutdown mode bit saves maximum power by shutting down all device circuitry other than the serial interface, reducing current consumption to typically less than 0.5 μ Shutdown mode is enabled when the SD bit is '1'; the device shuts down when current A fault condition exists when the measured conversion is completed. When SD is equal to '0', temperature exceeds the user-defined limits set in the device maintains a continuous conversion state. the T HIGH and T LOW registers. Additionally, the number of fault conditions required to generate an alert may be programmed using the fault queue. The fault queue is provided to prevent a false alert as a The Thermostat mode bit indicates to the device result of environmental noise. The fault queue whether to operate in Comparator mode (TM or requires consecutive fault measurements in order to Interrupt mode (TM 1). For more information on trigger the alert function. Table defines the number comparator and interrupt modes, see the High- and of measured faults that may be programmed to Low-Limit Registers section. trigger an alert condition in the device. For T HIGH and T LOW register format and byte order, see the High- and Low-Limit Registers section. The Polarity bit allows the user to adjust the polarity of the ALERT pin output. If POL the ALERT pin Table TMP102 Fault Settings will be active low, as shown in Figure For POL CONSECUTIVE FAULTS the ALERT pin will be active high, and the state of the ALERT pin is inverted. Submit Documentation Feedback
www.ti.com CONVERTER RESOLUTION (R1/R0) ONE-SHOT/CONVERSION READY (OS) HIGH- AND LOW-LIMIT REGISTERS BUS OVERVIEW TMP102 SBOS397 AUGUST 2007 Both operational modes are represented in Figure Table and Table describe the R1/R0 are read-only bits. The TMP102 converter format for the T HIGH and T LOW registers. Note that the resolution is set on start up to '11'. This sets the most significant byte is sent first, followed by the temperature register to a bit-resolution. least significant byte. Power-up reset values for T HIGH and T LOW are: T HIGH +80 C and T LOW +75 The format of the data for T HIGH and T LOW is the same as for the Temperature Register. The TMP102 a One-Shot Temperature Measurement mode. When the device is in Table 10. Bytes and of T HIGH Register (1) Shutdown mode, writing a to the OS bit starts a single temperature conversion. During the BYTE conversion, the OS bit reads '0'. The device returns H11 H10 to the shutdown state at the completion of the single (H12) (H11) (H10) (H9) (H8) (H7) (H6) (H5) conversion. After the conversion, the OS bit reads '1'. BYTE This feature is useful for reducing power consumption in the TMP102 when continuous temperature monitoring is not required. (H4) (H3) (H2) (H1) (H0) (0) (0) (0) (1) Extended mode 13-bit configuration shown in parenthesis. As a result of the short conversion time, the TMP102 can achive a higher conversion rate. A single Table 11. Bytes and of T LOW Register (1) conversion typically takes 26ms and a read can take place in less than μ When using One-Shot BYTE mode, or more conversions per second are L11 L10 possible. (L12) (L11) (L10) (L9) (L8) (L7) (L6) (L5) BYTE In Comparator mode (TM 0), the ALERT pin (L4) (L3) (L2) (L1) (L0) (0) (0) (0) becomes active when the temperature equals or (1) Extended mode 13-bit configuration shown in parenthesis. exceeds the value in T HIGH and generates a consecutive number of faults according to fault bits and F0. The ALERT pin remains active until the temperature falls below the indicated T LOW value for The device that initiates the transfer is called a the same number of faults. master and the devices controlled by the master are In Interrupt mode (TM 1), the ALERT pin becomes slaves The bus must be controlled by a master active when the temperature equals or exceeds the device that generates the serial clock (SCL), controls value in T HIGH for a consecutive number of fault the bus access, and generates the START and conditions (as shown in Table The ALERT pin STOP conditions. remains active until a read operation of any register To address a specific device, a START condition is occurs, or the device successfully responds to the initiated, indicated by pulling the data-line (SDA) from SMBus Alert Response address. The ALERT pin will a high to low logic level while SCL is high. All slaves also be cleared if the device is placed in Shutdown on the bus shift in the slave address byte on the mode. Once the ALERT pin is cleared, it becomes rising edge of the clock, with the last bit indicating active again only when temperature falls below T LOW whether a read or write operation is intended. During and remains active until cleared by a read operation the ninth clock pulse, the slave being addressed of any register or a successful response to the responds to the master by generating an SMBus Alert Response address. Once the ALERT Acknowledge and pulling SDA low. pin is cleared, the above cycle repeats, with the ALERT pin becoming active when the temperature Data transfer is then initiated and sent over eight equals or exceeds T HIGH The ALERT pin can also be clock pulses followed by an Acknowledge Bit. During cleared by resetting the device with the General Call data transfer SDA must remain stable while SCL is Reset command. This action also clears the state of high, because any change in SDA while SCL is high the internal registers in the device, returning the will be interpreted as a START or STOP signal. device to Comparator mode (TM 0). Once all data have been transferred, the master generates a STOP condition indicated by pulling SDA from low to high, while SCL is high. Submit Documentation Feedback
www.ti.com SERIAL INTERFACE SERIAL BUS ADDRESS SLAVE MODE OPERATIONS Slave Receiver Mode: WRITING/READING OPERATION Slave Transmitter Mode: TMP102 SBOS397 AUGUST 2007 Register. This action is accomplished by issuing a slave address byte with the W bit low, followed by The TMP102 operates as a slave device only on the the Pointer Register byte. No additional data are two-wire bus and SMBus. Connections to the bus required. The master can then generate a START are made via the open-drain I/O lines SDA and SCL. condition and send the slave address byte with the The SDA and SCL pins feature integrated spike W bit high to initiate the read command. See suppression filters and Schmitt triggers to minimize Figure for details of this sequence. If repeated the effects of input spikes and bus noise. The reads from the same register are desired, it is not TMP102 supports the transmission protocol for both necessary to continually send the Pointer Register fast (1kHz to 400kHz) and high-speed (1kHz to bytes, because the TMP102 remembers the Pointer 3.4MHz) modes. All data bytes are transmitted MSB Register value until it is changed by the next write first. operation. Note that register bytes are sent with the most significant byte first, followed by the least significant To communicate with the TMP102, the master must byte. first address slave devices via a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or write operation. The TMP102 can operate as a slave receiver or slave transmitter. As a slave device, the TMP102 The TMP102 line. four devices to be addressed on a single bus. Table describes the pin logic levels used to properly connect up to four devices. The first byte transmitted by the master is the slave Table 12. Address Pin and Slave Addresses address, with the W bit low. The TMP102 then acknowledges reception of a valid address. The next DEVICE TWO-WIRE PIN CONNECTION byte transmitted by the master is the Pointer ADDRESS Register. The TMP102 then acknowledges reception 1001000 Ground of the Pointer Register byte. The next byte or bytes 1001001 are written to the register addressed by the Pointer 1001010 SDA Register. The TMP102 acknowledges reception of each data byte. The master can terminate data 1001011 SCL transfer by generating a START or STOP condition. Accessing a particular register on the TMP102 is The first byte transmitted by the master is the slave accomplished by writing the appropriate value to the address, with the W bit high. The slave Pointer Register. The value for the Pointer Register acknowledges reception of a valid slave address. is the first byte transferred after the slave address The next byte is transmitted by the slave and is the byte with the W bit low. Every write operation to most significant byte of the register indicated by the the TMP102 requires a value for the Pointer Register Pointer Register. The master acknowledges (see Figure reception of the data byte. The next byte transmitted When reading from the TMP102, the last value by the slave is the least significant byte. The master stored in the Pointer Register by a write operation is acknowledges reception of the data byte. The master used to determine which register is read by a read can terminate data transfer by generating a operation. To change the register pointer for a read Not-Acknowledge on reception of any data byte, or operation, a new value must be written to the Pointer generating a START or STOP condition. Submit Documentation Feedback
www.ti.com SMBus ALERT FUNCTION HIGH-SPEED (Hs) MODE TIMEOUT FUNCTION NOISE GENERAL CALL TMP102 SCL SDA GND V+ ALERT ADD0 CF 10nF/c179 RF 5k/c163 /c87 Supply□Voltage TMP102 SBOS397 AUGUST 2007 The TMP102 supports the SMBus Alert function. In order for the two-wire bus to operate at When the TMP102 operates in Interrupt mode (TM frequencies above 400kHz, the master device must '1'), the ALERT pin may be connected as an SMBus issue an Hs-mode master code (00001xxx) as the Alert signal. When a master senses that an ALERT first byte after a START condition to switch the bus condition is present on the ALERT line, the master to high-speed operation. The TMP102 does not sends an SMBus Alert command (00011001) to the acknowledge this byte, but switches its input filters bus. If the ALERT pin is active, the device on SDA and SCL and its output filters on SDA to acknowledges the SMBus Alert command and operate in Hs-mode, allowing transfers at up to responds by returning its slave address on the SDA 3.4MHz. After the Hs-mode master code has been line. The eighth bit (LSB) of the slave address byte issued, the master transmits a two-wire slave indicates if the ALERT condition was caused by the address to initiate a data transfer operation. The bus temperature exceeding T HIGH or falling below T LOW continues to operate in Hs-mode until a STOP For POL '0', this bit is low if the temperature is condition occurs on the bus. Upon receiving the greater than or equal to T HIGH this bit is high if the STOP condition, the TMP102 switches the input and temperature is less than T LOW The polarity of this bit output filters back to fast-mode operation. is inverted if POL '1'. Refer to Figure for details of this sequence. If multiple devices on the bus respond to the SMBus The TMP102 resets the serial interface if SCL is held Alert command, arbitration during the slave address low for 30ms (typ). The TMP102 releases the bus if it portion of the SMBus Alert command determines is pulled low and waits for a START condition. To which device will clear its ALERT status. The device avoid activating the timeout function, it is necessary with the lowest two-wire address wins the arbitration. to maintain a communication speed of at least 1kHz If the TMP102 wins the arbitration, its ALERT pin for SCL operating frequency. becomes inactive at the completion of the SMBus Alert command. If the TMP102 loses the arbitration, its ALERT pin remains active. The TMP102 is a very low-power device and generates very low noise on the supply bus. Applying an RC filter to the pin of the TMP102 The TMP102 responds to a two-wire General Call can further reduce any noise the TMP102 might address (0000000) if the eighth bit is '0'. The device propagate to other components. R F in Figure acknowledges the General Call address and should be less than Ω and C F should be greater responds to commands in the second byte. If the than 10nF. second byte is 00000110, the TMP102 internal registers are reset to power-up values. The TMP102 does not support the General Address acquire command. Figure 11. Noise Reduction Submit Documentation Feedback
www.ti.com TIMING DIAGRAMS TMP102 SBOS397 AUGUST 2007 Data Transfer: The number of data bytes transferred between a START and a STOP condition is not The TMP102 is two-wire and SMBus compatible. limited and is determined by the master device. It is Figure to Figure describe the various also possible to use the TMP102 for single byte operations on the TMP102. Parameters for Figure updates. To update only the MS byte, terminate the are defined in Table Bus definitions are: communication by issuing a START or STOP communication on the bus. Bus Idle: Both SDA and SCL lines remain high. Acknowledge: Each receiving device, when Start Data Transfer: A change in the state of the addressed, is obliged to generate an Acknowledge SDA line, from high to low, while the SCL line is bit. A device that acknowledges must pull down the high, defines a START condition. Each data transfer SDA line during the Acknowledge clock pulse in such is initiated with a START condition. a way that the SDA line is stable low during the high Stop Data Transfer: A change in the state of the period of the Acknowledge clock pulse. Setup and SDA line from low to high while the SCL line is high hold times must be taken into account. On a master defines a STOP condition. Each data transfer is receive, the termination of the data transfer can be terminated with a repeated START or STOP signaled by the master generating a condition. Not-Acknowledge ('1') on the last byte that has been transmitted by the slave. Table 13. Timing Diagram Definitions FAST MODE HIGH-SPEED MODE PARAMETER TEST CONDITIONS MIN MAX MIN MAX UNIT f (SCL) SCL Operating Frequency, V S 1.7V 0.001 0.4 0.001 3.4 MHz f (SCL) SCL Operating Frequency, V S 1.7V 0.001 0.4 0.001 2.75 MHz Bus Free Time Between STOP and START t (BUF) 600 160 ns Condition Hold time after repeated START condition. t (HDSTA) 100 100 ns After this period, the first clock is generated. t (SUSTA) Repeated START Condition Setup Time 100 100 ns t (SUSTO) STOP Conditon Setup Time 100 100 ns t (HDDAT) Data Hold Time ns t (SUDAT) Data Setup Time 100 ns t (LOW) SCL Clock Low Period, V S 1.7V 1300 160 ns t (LOW) SCL Clock Low Period, V S 1.7V 1300 200 ns t (HIGH) SCL Clock High Period 600 ns t F Clock/Data Fall Time 300 ns t R Clock/Data Rise Time 300 160 ns t R Clock/Data Rise Time for SCLK 100kHz 1000 ns Submit Documentation Feedback
www.ti.com TWO-WIRE TIMING DIAGRAMS SCL SDA t(LOW) tR tF t(HDST A) t(HDST A) t(HDDA T) t(BUF) t(SUDA T) t(HIGH) t(SUST A) t(SUSTO) P S S P Frame□1□T wo-Wire□Slave□Address□Byte Frame□2□Pointer□Register□Byte Frame□4□Data□Byte□2 Start□By Master ACK□By TMP102 ACK□By TMP102 ACK□By TMP102 Stop□By Master 1 9 1 D7 D6 D5 D4 D3 D2 D1 D0 Frame□3□Data□Byte□1 ACK□By TMP102 D7SDA (Continued) SCL (Continued) D6 D5 D4 D3 D2 D1 D0 SDA SCL 0 0 1 0 A1(1) A0(1) R/W 0 0 0 0 0 0 P1 P0 /c188 /c188 TMP102 SBOS397 AUGUST 2007 Figure 12. Two-Wire Timing Diagram Figure 13. Two-Wire Timing Diagram for Write Word Format Submit Documentation Feedback
www.ti.com Frame□1□T wo-Wire□Slave□Address□Byte Frame□2□Pointer□Register□Byte Start□By Master ACK□By TMP102 ACK□By TMP102 Frame□3□T wo-Wire□Slave□Address□Byte Frame□4□Data□Byte□1□Read□Register Start□By Master ACK□By TMP102 ACK□By Master(2) From TMP102 1 9 1 9 1 9 1 9 SDA SCL 0 0 1 R/W 0 0 0 0 0 0 P1 P0 /c188 /c188 /c188 SDA (Continued) SCL (Continued) SDA (Continued) SCL (Continued) 1 0 0 1 0 A1 (1) (1) 0 A1 (1) (1) R/W D7 D6 D5 D4 D3 D2 D1 D0 Frame□5□Data□Byte□2□Read□Register Stop□By Master ACK□By Master(3) From TMP102 1 9 D7 D6 D5 D4 D3 D2 D1 D0 Stop□By Master NOTE: (1)□The□value□of□A0□and□A1□are□determined□by□the□ADD0□pin. (2)□Master□should□leave□SDA□high□to□terminate□a□single-byte□read□operation. (3)□Master□should□leave□SDA□high□to□terminate□a□two-byte□read□operation. Frame□1□SMBus□ALERT□Response□Address□Byte Frame□2□Slave□Address□From□TMP100 Start□By Master ACK□By TMP102 From TMP102 NACK□By Master Stop□By Master 1 9 1 9 SDA SCL ALERT 0 0 0 1 1 0 0 R/ W 1 0 0 1 A1 A0 Status TMP102 SBOS397 AUGUST 2007 Figure 14. Two-Wire Timing Diagram for Read Word Format Figure 15. Timing Diagram for SMBus ALERT Submit Documentation Feedback
Orderable Device Status(1) Package Type Package Drawing Pins Package Qty Eco Plan(2) Lead/Ball FinishMSL Peak Temp (3) TMP102AIDRLR ACTIVE SOT-553 DRL 6 4000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TMP102AIDRLT ACTIVE SOT-553 DRL 6 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM (1)The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2)Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontentfor the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS):TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt):This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br):TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. PACKAGE OPTION ADDENDUM www.ti.com 15-Aug-2007 Addendum-Page 1
PACKAGE MATERIALS INFORMATION www.ti.com 15-Aug-2007 Pack Materials-Page 1
Device Package Pins Site Reel Diameter (mm) Reel Width (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W (mm) Pin1 Quadrant TMP102AIDRLR DRL 6 HNT 180 9 1.78 1.78 0.69 4 8 Q3 TMP102AIDRLT DRL 6 HNT 180 9 1.78 1.78 0.69 4 8 Q3 TAPE AND REEL BOX INFORMATION Device Package Pins Site Length (mm) Width (mm) Height (mm) TMP102AIDRLR DRL 6 HNT 202.0 201.0 28.0 TMP102AIDRLT DRL 6 HNT 202.0 201.0 28.0 PACKAGE MATERIALS INFORMATION www.ti.com 15-Aug-2007 Pack Materials-Page 2
(TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for design. Customers are responsible for their products and components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security RFID www.ti-rfid.com Telephony www.ti.com/telephony Low Power www.ti.com/lpw Video Imaging www.ti.com/video Wireless Wireless www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright 2007, Texas Instruments Incorporated