Safety module, Modicon TM3 Safety, 1 Function, Cat 3 PL d/SIL CL2 (screw) 24 VDC TM3SAC5R Main Range of product Modicon TM3 Safety Product or component type Safety module Device short name TM3SAC Safety module application For emergency stop and switch monitoring Function of module Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start Safety level Can reach PL d/category 3 conforming to EN/ISO 13849-1: 2008 Can reach PL d/category 3 conforming to EN/ISO 13849-2: 2012 Can reach SILCL 2 conforming to EN/IEC 62061: 2005 Can reach SIL 2 conforming to EN/IEC 61508: 2010 Complementary Safety reliability data DC = 95 % conforming to EN/ISO 13849-1 PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A SFF = 95 % conforming to IEC 61508-1 HFT = 1 conforming to IEC 61508-1 Type = A conforming to IEC 61508-1 Synchronisation time between inputs Unlimited end 13-14, 23-24, 33-34 with bezel 13-14, 23-24, 33-34 without bezel 13-14, 23-24, 33-34 end 13-14, 23-24, 33-34 Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 with double bezel 13-14, 23-24, 33-34 end other terminals other terminals with bezel other terminals without bezel other terminals end other terminals end other terminals Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Apr 4, 2022

end, without bezel other terminals Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals Output type Relay instantaneous opening, 3 NO circuit(s), potential free Number of safety circuits 3 NO for relay instantaneous opening Maximum switching voltage 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)

24 V utilisation category DC-13 (relay instantaneous opening)

[Us] rated supply voltage 24 V - 15...20 % DC Power consumption in W 0.2 W at 5 V DC

3.6 W at 24 V DC

Input protection type Internal, electronic [Uc] control circuit voltage 24 V DC Maximum cable distance between devices 30 m Breaking capacity 360 VA holding AC-15 B300 relay output

3600 VA inrush AC-15 B300 relay output

Breaking capacity 4 A 24 V 50 ms DC-13 relay output Output thermal current 6 A per relay for relay output [Ith] conventional free air thermal current 18 A Associated fuse rating 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1

6 A fast blow for relay output conforming to EN/IEC 60947-5-1

Minimum output current 10 mA for relay output Output voltage 10 V relay output Maximum response time on input open 40 ms [Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60647-5-1 [Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60647-5-1 Current consumption 100 mA at 24 V DC external supply (at state on) Local signalling 6 LEDs (green/red) for user Electrical connection Screw terminal Standards EN/ISO 13849-1:2008 EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 Product certifications TÜV CSA 61010-2-201 (pending) CSA Haz Loc Class 1 Division 2 (pending) RCM ANSI Haz Loc Class 1 Division 2 (pending) EAC UL 61010-2-201 Marking EFUP 10 RCM CSA UL TÜV CE EAC Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 Apr 4, 2022

Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011 Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011 Mounting support Top hat type TH35-7.5 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715 wall mount using attached fasteners Height 94 mm Depth 73 mm Width 43.7 mm Net weight 0.19 kg Environment Standards EN 1088/ISO 14119 EN/ISO 13850 EN/IEC 60947-1 EN 60204-1 EN/IEC 60947-5-1 Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2 6 kV on contact conforming to EN/IEC 61000-4-2 Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 Resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 Resistance to fast transients 3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4 2 kV for I/O lines conforming to EN/IEC 61000-4-4 Surge withstand 1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 Electromagnetic emission Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3 Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3 Ambient air temperature for operation -10…55 °C horizontal installation Ambient air temperature for storage -25…70 °C Relative humidity 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) IP degree of protection IP20 (terminals) conforming to EN/IEC 60529 Pollution degree 2 Operating altitude 0...2000 m Storage altitude 0…3000 m Vibration resistance +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Mechanical robustness Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27 Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 279.0 g Apr 4, 2022

Package 1 Height 7.5 cm Package 1 width 10.6 cm Package 1 Length 12.5 cm Unit Type of Package 2 S03 Number of Units in Package 2 18 Package 2 Weight 5.522 kg Package 2 Height 30 cm Package 2 width 30 cm Package 2 Length 40 cm Offer Sustainability Sustainable offer status Green Premium product REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins PVC free Yes California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Apr 4, 2022

(*) 8.5 mm/0.33 in when the clamp is pulled out. Apr 4, 2022

Apr 4, 2022

Apr 4, 2022

Mounting on a Panel Surface (1) Install a mounting strip Mounting Hole Layout Apr 4, 2022

Emergency Stop Wiring Diagram S1 : Emergency stop switch S2 : Start switch (1) Safety outputs (2) For automatic start, directly connect [Y1] and [Y2] terminals (3) Fuses. Refer to technical specifications for fuse values (4) Non-safety related TM3 Bus communication with logic controller Apr 4, 2022