Energy Management and Building Automation > Energy Management and Metering > Transducers and Transformers > IME Transducers > AC Current Transducers TRANSDUCER INPUT 5A OUTPUT 4-20mA AUX 110V AC TM3I230 Catalogue No:

  • Available for AC or DC measurement
  • Multiple selectable DC outputs 0 to 5/10/20mA, 4 to 20mA, 10V
  • Compact DIN mount design
  • Basic or Field programmable units available Representative Photo Only (actual product may vary based on configuration selections) TRANSD 5A IP 0-5/10/20mA, 4-20mA OP 115V AC SPECIFICATIONS Product Series Component Type Metering Meter Type(s) In, Rated Current Current, Overload Capacity, Continuous Current, Overload Capacity, 1s (rms) Rated Frequency Operational Frequency, Min Operational Frequency, Max Burden, Rated Input Range(s) Unom, Supply Voltage, AC, Nom Output Range(s) Accuracy Class Response Time (Off → On) Compliance Voltage Efficiency, Ripple Content Pollution Degree Installation Category Ui, Rated Insulation Voltage Impulse Withstand Test Voltage Power Dissipation, Max Reverse Polarity Protection Wire / Conductor Size (Max) Material, Body / Housing Number of Modules TM3I AC/DC Transducer Transducer - AC Current 5 A 0.018 kA 0.12 kA 50 Hz

47 Hz min

63 Hz max

0.2 VA 0 ... 5A

115 V AC

0 ... 5mA 0 ... 10mA 0 ... 20mA 4 ... 20mA

0.5 Class

1 % III

450 V (rms)

2.6 W Yes Y/N 4 mm² PC (Polycarbonate) material 2 qty Page 1 of 211 October 2022,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com TM3I230 DatasheetNHP Electrical Engineering Products

Energy Management and Building Automation > Energy Management and Metering > Transducers and Transformers > IME Transducers > AC Current Transducers TRANSDUCER INPUT 5A OUTPUT 4-20mA AUX 110V AC TM3I230 Catalogue No: Connection Method IP Rating, Front IP Rating, Back Terminal Type Height Width Depth Weight Storage Temperature, Max Storage Temperature, Min Operating Temperature, Max Operating Temperature, Min Relative Humidity, Max Standards Compliance CT connect IP40 IP20 Screw Terminal(s) 89 mm 35 mm 65.6 mm 0.2 kg 70 °C max -25 °C min 45 °C max 0 °C min 75 %RH EN 50081-1 EN 50082-2 EN 55011 EN 60439-1 EN 60529 EN 60688 EN 60715 REFERENCES Installation Guide: - User Manual: - Manufacturer Datasheet: - Manufacturer Catalogue & Product Selection: - Supplier Declaration of Conformity: - IECEx Certificate - Page 2 of 211 October 2022,1300 NHP NHP | nhp.com.au | 0800 NHP NHP | nhp-nz.com TM3I230 DatasheetNHP Electrical Engineering Products