TLP150-M EMERSON-NETWORKPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Business-Critical Continuity TLP150-M Series Single output Special Features

  • 150 W on main channel with only 200 LFM
  • Low profile fits 1U applications
  • Active PFC and EN61000-3-2 compliant
  • Integrated control and monitoring features
  • Overcurrent, overvoltage and overtemperature protection
  • Compliance to EN55022-B conducted noise standard
  • 12 V fan output
  • 5 V standby output (optional)
  • RoHS compliant
  • 2 year warranty Total Power: 150W Input Voltage: 85 - 264VAC # of Outputs: Single Safety VDE EN60601-1/IEC60601-1 UL2601-1/CSA22.2 No. 601-1 Rev.12.23.08_140 TLP150-M Series 1 of 4 Electrical Specifications RoHS Input Input voltage range: Universal Input 85-264 Vac Input frequency range: 47-63 Hz Input surge current: 264 Vac (cold start) 40 A max. Safety ground leakage current: 264 Vac, 50 Hz 150 µA Input current: 120 Vac @ 150 W

230 Vac @ 150 W

1.8 A rms

0.8 A rms

Input fuse: UL/IEC127 T 3.15 A, 250 Vac Output Total regulation (line and load): Main output Auxiliary outputs Fan output ±3% ±5% ±10% Turn-on delay: @120 Vac Input 2.0 s max. Transient response: Main output 25% to 75% step at 0.5 A/µs max. dev., 1 ms max. recovery to 1% Temperature coefficient: ±0.02%/°C Overvoltage protection: Main outputs 25%, ±5% Short circuit protection: Current limited Continuous Minimum output current: Singles 0 A Fan voltage output: See Note 9 12 V @ 0.5 A Standby output: See Note 9 5 V @ 1.0 A

Rev.12.23.08_140 TLP150-M Series 2 of 4 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 Environmental Specifications Thermal performance Operating ambient, (See derating curve) 0° C to +70 °C Non-operating -40 °C to +85 °C 0 °C to 50 °C ambient,

200 LFM forced air

0 °C to 50 °C ambient, convection cooled 100 W 50 °C to 70 °C ambient, convection cooled Derate linearly to 50% load Relative humidity Non-condensing 5-95% RH Altitude Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 7) 5-500 Hz 2.4 G rms peak Shock per MIL-STD-810E 516.4 Part IV EMC Characteristics (5) Conducted emissions EN55022, FCC part 15 Level B Harmonic current correction EN61000-3-2 Compliant ESD air EN61000-4-2 Level 3 ESD contact EN61000-4-2 Level 3 Radiated immunity EN61000-4-3 Level 3 Fast transients EN61000-4-4 Level 3 Surge EN61000-4-5 Level 3 Conducted immunity EN61000-4-6 Level 3 General Specifications Hold-up time 850 Vac @ 60 Hz 20 ms @ 150 W Efficiency 115 Vac @ 150 W 81% typ. 84% typ. Isolation voltage Input/output Input/chassis

4000 Vac

1500 Vac

Weight 260g (9.2 oz) MTBF (@25º C) Telcordia SR-332 MIL-HDBK-217F 900,000 hours min. 350,000 hours min.

Dimensions in Inches (mm) ø0.156 (4 Places) 0.225 (5.72) 0.225 (5.72) FAN 4.550 (115.57) 5.000 (127.00) 3.000 (76.20) 2.550 (64.77) 1.250 (31.75) Outline Dimensions

1 J301

Rev.12.23.08_140 TLP150-M Series 3 of 4 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 Figure 2: Mechanical Drawing DERATING CURVE Output Power (Watts)

0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C

200 LFM (1.0 m/s) FORCED AIR COOLING NATURAL CONVECTION COOLING 50 W 75 W 0 W Figure 1: Derating Curve

Ordering Information

Ripple Total Regulation Model Numbers Min Max (free air)(1,4) Max (forced air)(2,4) 12 V 0 A 8.4 A 12.5A 120 mV ±3.0% TLP150N-99S12J 24 V 0 A 4.2A 6.3 A 240 mV ±3.0% TLP150N-99S24J Notes 1 Free air convection. Maximum continuous output power not to exceed 100W. Refer to Figure 1 for the derating curve. 2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not to exceed 150 W. 3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF tantalum capacitor and a 0.1 µF ceramic capacitor.

4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making

thermal measurements. For optimum reliability no part of the heatsink should exceed 115 °C and no semi-conductor case temperature should exceed 120 °C.

5 No external filtering required during conducted emissions testing but some applications

may require additional filtering to achieve system compliance. Compliance with radiated EMI specifications may require mounting in a suitable enclosure.

6 This product is only for inclusion by professional installers within other equipment and

must not be operated as a stand alone product. 7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G.

8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output

and/or remote ON/OFF control is required e.g. TLP150N-99S12FJ. 9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is available whenever ac input is present, regardless of remote ON/OFF signal status. 10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 11 NOTICE: Some models do not support all options. Please contact your local Emerson representative or use the on-line model number search tool at http://www.powerconversion.com to find a suitable alternative..

Business-Critical Continuity Rev.12.23.08_140 TLP150-M Series 4 of 4Connector and Mating Connector Types Connector Type Mating Connector Type J1 Molex 09-65-2038 (5273 series) void pin 2 or equivalent Molex 09-52-4034 (5239 series) or equivalent with Molex 08-52-0072 (2478 series) or equivalent crimp terminals J3 Molex 09-65-2068 (5273 series) or equivalent Molex 09-52-4064 (5239 series) or equivalent with Molex 08-52-0072 (2478 series) or equivalent crimp terminals J301 (Optional) Leoco 2421P04H000 (2421 series) or equivalent Leoco 2420S04000 (2420 series) or equivalent with Leoco 2453TPH00V1 (2453T series) or equivalent crimp terminals or JST EHR-4 (EH series) or equivalent with JST SEH-001T-P0.6 (EH series) or equivalent crimp terminals Fan Molex 22-23-2021(6373 series) or equivalent Molex 22-01-3027 (2695 series) or equivalent with Molex 08-50-0113 (2759 series) or equivalent crimp terminals Americas

5810 Van Allen Way

Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower@ emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power J1 Pin Connections Pin 1 Neutral Pin 3 Live J2 Tab Connections Tan Ground/Earth Fan Pin Connections Pin 1 +12 V Fan Voltage Pin 2 +SGND Return J301 Pin Connections (Optional) Pin 1 5 Vsb Standby Voltage Pin 2 SGND Signal Common Pin 3 Reserved Do Not Connect Pin 4 PS OFF Remote ON/OFF Signal J4 Pin Connections Pin 1 -S -Vo Remote Sense Pin 2 DC OK DC Power Good Signal Pin 3 PW OK Power Good Pin 4 LS Load Share Signal Pin 5 +S +Vo Remote Sense Pin 6 SGND Signal Common J3 Pin Connections Pin 1 RTN Main Return Pin 2 RTN Main Return Pin 3 RTN Main Return Pin 4 Vo +Main Output Pin 5 Vo +Main Output Pin 6 Vo +Main Output