As Easy To Install as a Microswitch
- A compact Proximity Sensor with the feel of a microswitch. Be sure to read Safety Precautions on page 4.
Ordering Information
Note: Models with different frequencies are also available. The model numbers are TL-M @M@@5 (e.g., TL-M2ME15). Ratings and Specifications Appearance Sensing distance Output specifications Model Operation mode NO NC DC 3-wire, NPN voltage output TL-M2ME1 2M TL-M2ME2 2M AC 2 wire TL-M2MY1 2M --- DC 3-wire, NPN voltage output TL-M5ME1 2M TL-M5ME2 2M AC 2 wire TL-M5MY1 2M --- Item Model TL-M2ME1, TL-M2ME2, TL-M2MY1 TL-M5ME1, TL-M5ME2, TL-M5MY1 Sensing distance 2 mm ±10% 5 mm ±10% Set distance 0 to 1.6 mm 0 to 4 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 2.) Standard sensing object Iron, 15 × 15 × 1 mm Response frequency E Models: 500 Hz, Y Models: 20 Hz E Models: 250 Hz, Y Models: 20 Hz Power supply voltage (operating voltage range) E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max. Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz Current consumption E Models: 15 mA max. at 24 VDC (no-load) Leakage current Y Models: 2.5 mA max. at 200 VAC Control output Load current E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC Y Models: 10 to 200 mA Residual voltage E Models: 1 V max. Y Models: Refer to Residual Output Voltage under Engineering Data on page 3. Indicators E Models: Detection indicator (red) Y Models: Operation indicator (red) Operation mode (with sens- ing object approaching) E1/Y1 Models: NO E2 Models: NC Protection circuits E Models: Reverse polarity protection, Surge suppressor Y Models: Surge suppressor Ambient temperature range Operating/Storage: −25 to 70°C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Microswitch type 2 mm 5 mm Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.
Engineering Data (Typical) Item Model TL-M2ME1, TL-M2ME2, TL-M2MY1 TL-M5ME1, TL-M5ME2, TL-M5MY1 Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence E Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range Y Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength E Models: 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 75 g Materials Case Heat-resistant ABS Sensing surface Accessories Instruction manual Sensing Area Leakage Current TL-M2@/M5@ TL-M@MY1 Influence of Sensing Object Size and Material TL-M2ME TL-M2MY1 TL-M5M X 0 −4−6−8 Y 86420−2 TL-M5M Standard sensing object Iron, 15 × 15 t = 1 mm TL-M2M Standard sensing object Iron, 12 × 12 t = 1 mm Distance X (mm) Sensing Head Distance Y (mm) 100 150900 A 250200 Power supply voltage (V) Protective resistance AC power Leakage current (mA) 1.0 0.5 2.5 2.0 1.5 5040302010 X d × d t = 1 mm Side length of sensing object: d (mm) Stainless steel (SUS304) Note: Does not operate for brass or aluminum. Iron Distance X (mm) 1.0 0.5 20100 2.5 2.0 1.5 X 504030 d × d t = 1 mm Side length of sensing object: d (mm) Stainless steel (SUS304) Aluminum Iron Brass Distance X (mm) 100 6050403020 X d × d t = 1 mm Side length of sensing object: d (mm) Stainless steel (SUS304) Aluminum Iron Brass Distance X (mm)
TL-M@MY1 at 100 VAC TL-M @MY1 at 200 VAC Operation mode Output specifi- cations Model Timing chart Output circuit NO NPN TL-M2ME1 TL-M5ME1 NC TL-M2ME2 TL-M5ME2
100 VAC
A V ON100 01 0 5 200 50 100 150 OFF Load current (mA) Residual output voltage Residual load voltage Load voltage VL (V) 01 0 5 05 OFF 200100 150 V A
200 VAC
Load current (mA) Residual Output Voltage Residual load voltage Load voltage VL (V) Sensing object Present None Load (between brown and black leads) Operate Reset Output voltage (between black and blue leads) High Low Detection indicator (red) ON OFF *1. 200 mA max. (load current). *2. When a transistor is connected. 100 Ω 4.7 kΩ 2.2 Ω *2 0 V Tr Load Brown Black Blue Output Prox- imity Sensor main circuit Sensing object Present None Load (between brown and black leads) Operate Reset Output voltage (between black and blue leads) High Low Detection indicator (Red) ON OFF Operation mode Model Timing chart Output circuit NO TL-M2MY1 TL-M5MY1 Sensing object Present None Load Operate Reset Operation indicator (Red) ON OFF Prox- imity Sensor main circuit Load Blue Brown
Refer to Warranty and Limitations of Liability. This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not use this product under ambient conditions that exceed the ratings.
- Design Influence of Surrounding Metal When installing Sensors on metal surfaces or near metal, ensure that the minimum distances given in the following table are maintained. Influence of Surrounding Metal (Unit: mm) Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. Mutual Interference (Unit: mm) Note: Values in parentheses apply to Sensors operating at different frequencies.
- Mounting The maximum tightening torque that should be applied to the mounting screws is 0.98 N·m. Dimensions WARNING Precautions for Correct Use Model Distance A B C TL-M2M 12 10 15 TL-M5M 18 25 30 A B C Note: For direct mounting, the distance “C” will equal 0 only in the shaded section of the above left-side section. Model Distance A B C D TL-M5M 120 (60) 80 (40) 70 (30) 50 (10) A B C D (Unit: mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. 10 dia. 23.3 18.7 18.7 17.5 28.45 25.4±0.2 11.9 49.2 4.36 4.2 Indicator * E Models: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm 2, Insulator diameter: 1.2 mm), Standard length: 2 m Y Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm 2, Insulator diameter: 1.3 mm), Standard length: 2 m * E Models: Detection indicator (red), Y Models: Operation indicator (red) TL-M2M 25.4±0.2 11.9 49.2 18.7 24.7 4.2 4.36 10 dia. 23.3 17.5
28.45 Indicator *
E Models: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm 2, Insulator diameter: 1.2 mm), Standard length: 2 m Y Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm 2, Insulator diameter: 1.3 mm), Standard length: 2 m * E Models: Detection indicator (red), Y Models: Operation indicator (red) TL-M5M
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.