This guide is designed to help you set up and install the TL70 Modular Tower Light. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com. Search for p/n 182214 to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices. Configuring the Modules 1 2 3 4 5 6 7 8 9 10 Turn on the appropriate DIP switch to set the order of the components, counting up from the tower light's base. Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Base Assembly Options DIP Switches 1 2 3 4 5 6 7 8 Light and Standard Audible Components Module 1 ON Module 2 ON Module 3 ON Module 4 ON Module 5 ON Module 6 ON Light Module Flash Rate
3 Hz ON OFF
1.5 Hz ON ON
Solid On* OFF OFF Standard Audible Module Settings Pulse 1.5 Hz ON OFF Chirp Alarm ON ON Siren Alarm OFF ON Continuous Alarm* OFF OFF Assembly Options DIP Switches 1 2 3 4 5 6 7 8 9 10 Loud Audible Module Settings Pulse 1.5 Hz ON OFF Chirp Alarm ON ON Siren Alarm OFF ON Continuous Alarm* OFF OFF Low Intensity OFF OFF Med. Intensity ON OFF Med./Loud Intensity OFF ON Loud Intensity ON ON * Factory default setting TL70 Modular Tower Light Original Document 182215 Rev. G
10 October 2017
To assemble the modules: 1. Align the notches on each module and press together. 2. Rotate the top module clockwise to lock into place (notches shown in the locked position). Wiring Diagrams PNP Input Module 12–30 V dc NPN Input Module 12–30 V dc Euro-style Male Pinouts Key 1 = brown 2 = white 3 = blue 4 = black 5 = gray M1 = Module 1 M2 = Module 2 M3 = Module 3 M4 = Module 4 PNP Input 12–30 V dc Module Not Used NPN Input 12–30 V dc Module Not Used Euro-style Male Pinouts Key 1 = white 2 = brown 3 = green 4 = yellow 5 = gray 6 = pink 7 = blue 8 = red M1 = Module 1 M2 = Module 2 M3 = Module 3 M4 = Module 4 M5 = Module 5 M6 = Module 6 TL70 Modular Tower Light 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 182215 Rev. G
0 = dc common 1 = Module 1 2 = Module 2 3 = Module 3 4 = Module 4 5 = Module 5 6 = Module 6 Specifications Supply Voltage and Current
12 V dc to 30 V dc
Indicator Color or Audible Model Maximum Current (mA) at 12 V dc at 30 V dc Blue, Green, White 420 150 Red, Yellow, Orange 285 120 Standard Audible 30 30 Loud Audible (Intensity 1) 30 25 Loud Audible (Intensity 2) 50 40 Loud Audible (Intensity 3) 165 75 Loud Audible (Intensity 4) 350 120 Supply Protection Circuitry Protected against transient voltages Indicators 1 to 6 colors depending on model (Green, Red, Yellow, Blue, White, and Orange) LEDs are independently selected Flash Rates: 1.5 Hz ±10% and 3 Hz ±10% Indicator Response Time Off Response: 150 µs (maximum) at 12 to 30 V dc On Response: 180 ms (maximum) at 12 V dc; 50 ms (maximum) at 30 V dc Audible Alarm Standard Audible: 2.6 kHz ± 250 Hz oscillation frequency; maximum intensity (typical) 92 dB at 1 m (3.3 ft) Loud Audible: 2.6 kHz ± 250 Hz oscillation frequency; maximum intensity (typical) at 1 m (3.3 ft) (see table) DIP Switches Max Intensity (Loud Audible) 9 10 ON ON Intensity 4: 101 dB OFF ON Intensity 3: 99 dB ON OFF Intensity 2: 92 dB OFF OFF Intensity 1: 85 dB Audible Adjustment Standard Audible: Rotate the cover until the desired volume is reached Loud Audible Alarm: Select the desired volume using DIP switches 9 and 10 Typical Reduction in Sound Intensity with Audible Adjustment (maximum to minimum):
- Standard Audible: 8 dB
- Loud Audible: 16 dB Construction Bases, Segments, Covers: polycarbonate TL70 Modular Tower Light P/N 182215 Rev. G www.bannerengineering.com - Tel: +1-763-544-3164 3
Color Dominant Wavelength (nm) or Color Temperature (CCT) Color Coordinates1 Lumen Output (Typical at 25 °C)x y Green 525 nm – – 92 Red 625 nm – – 40 Yellow 590 nm – – 22 Blue 470 nm – – 32 White 5000 K – – 125 Orange – 0.66 0.33 33 Connections 5-pin M12/Euro-style quick disconnect connector, 8-pin M12/Euro-style quick disconnect connector, 150 mm (5.9 in) PVC cable with an M12/Euro-style quick disconnect connector, terminal block, or 2 m (6.5 ft) unterminated cable, depending on model Terminal Block Models 14 to 28 AWG wire Operating Conditions 95% at +50 °C maximum relative humidity (non-condensing) Environmental Rating IEC IP65 Certifications Vibration and Mechanical Shock Vibration 10 Hz to 55 Hz 0.5 mm p-p amplitude per IEC 60068-2-6 Shock 15G 11 ms duration, half sine wave per IEC 60068-2-27 Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. 1 Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. TL70 Modular Tower Light © Banner Engineering Corp. All rights reserved