TFV3X110C-R100 RCD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
Ω Ω Ω Ω Ω 5% /boxshadowup Meets UL, FCC, REA, and EIA requirements /boxshadowup Fusing-to-operating current ratio as low as 1.25:1! /boxshadowup Fusing times can be custom tailored /boxshadowup Precision tolerance to ±0.1%, TC’s to 5ppm available /boxshadowup Available on exclusive SWIFT TM delivery program If a custom model is required, please advise the continuous wattage rating, ambient temperature, fusing wattage or current, min/max blow time, resistance value & tolerance, maximum size, pulse voltage & waveform, and a general description of the application. SPECIFICATIONS (133°C fuse design) DCR epyT 1 egattaW C°52@ 2 xaM/niM gnisuF egnaR 3 egatloV gnitaR 4 ecnatsiseR 5RFTW 5W 005otW7V 0025 0. Ω K04ote vobanoitartsullieeS ecnareloTe lbaliava%01ot%1.0 tneiciffeoCerutarepmeT. liava/mpp5±ots'.C.T,dradnatsmpp001± htgnertScirtceleiDC AV005 ecnatsiseRnoitalusnI) yrd(.nimsmhogem000,01 egnaR.pmeTgnitarepO) .liavaC°522otpu(C°021+ot55- gnitareDC °02evobaC°/%1 (gnitaResuF) C°5± ralupoprehtO.V052A2C°331=dradnatS C°781dnaC,°761,C°011erasledom )A52otA5.0,elbaliavaC°042+otC°27( VFT:emiTesuFdradnatS nihtiwesufllahsseireS ,rewopdetarx02taS03 esufllahsRFTdnaFT .Wdetarx03@S03nihtiw .xorpparoftrahcotrefeR esufs evrucg nisufmotsuc( .)elbaliava 1 Other sizes available from 1/2W to 60W. 2 Wattage rating based on 167°C fuse, deduct 24% for 133°C and 40% for 110°C. 3 Expanded range available 4 Maximum resistor working voltage determined by E = ( PR)1/2, E not exceed value listed 5 Resistance range from .005Ω to 1MΩ available. 6 Opt.A standoffs are avalable on TF1/2 - TF07 (not available on TF02) FA099B Sale of this product is in accordance with GF-061. Specifications subject to change without notice. OPTIONS /boxshadowup Option X: Low inductance design /boxshadowup Option P: high pulse design (consult factory for assistance) /boxshadowup Option A: ceramic case with standoffs (standard on TFV) /boxshadowup Customized fuse time/temp, Hi-rel screening & burn-in, increased V & W, aluminum-housed heat sink design, etc. RCD Components Inc, 520 E.Industrial Park Dr, Manchester, NH, USA 03109 rcdcomponents.com Tel: 603-669-0054 Fax: 603-669-5455 Email:sales@rcdcomponents.com 10 20 30 50 100 200 300 500 Approx. Fusing Time (Seconds) Power (Watts) 100W 10W 50W 30W TF02, TFV5 TFV2 TFV3 TF04 TFR5 RCD TFV3 100ΩΩΩΩΩ 5% TF Series SCHEMATIC L D (standoffs apply to Opt.A only, not avail on TF02) C TFV Series ← L → C .033” max. .200 ±.08 [5.08±2] ← B→ → ← .150 [3.8] min. Fuse is soldered between the resistor and metal mounting bracket, therefore easily replaceable in field TFR Series .032x.08” (3PL) .045” dia. TFR5 Mounting Layout .20” .20” .41” .032”±.004 .125” min. .41” .400” 2.45” Max RCD TF05A 100Ω Ω Ω Ω Ω 5% RCD’s TF Series construction consists of a thermal fuse welded in series with a resistor element. The assembly is potted inside a ceramic case (model TFR fuse is mounted externally in order to provide field-replaceability of the fuse). Under overload conditions, the thermal fuse “senses” the temperature rise of the resistor element and opens upon reaching a predetermined temperature. Devices can be custom tailored to specific fault conditions and do not require the large power overloads necessary with other fuse resistors to achieve proper fusing. Thus, the TF Series offers great safety, since high temperatures are not involved to achieve fusing. Typical applications include telecom line cards, repeaters, trunk carrier systems, RFI suppression, power supply, medical, and automotive circuits. RESISTORS /rhombus4CAPACITOR S/rhombus4C OILS /rhombus4DELAY LINESTHERMAL FUSE RESISTORS, 1/2W to 60W PERMANENT OR REPLACEABLE FUSE TF SERIES P/N DESIGNATION: TFV3 - 102 - J B W Resis. Code 1% & tighter tols: 3 signif. digits & multiplier, e.g. R100= 0.1Ω , 1R00= 1Ω ,1000= 100Ω , 1001= 1KΩ . 2%- 5%: 2digits &multiplier R10= .1Ω, 1R0=1Ω ,100=10Ω , 102=1K Optional TC: 5= 5ppm, 10 = 10ppm, 20 = 20ppm, 30 = 30ppm, 50 = 50ppm (leave blank if std) RCD Type Options: X, P , A (leave blank if standard) Tolerance: J=5%, G=2%, F=1%, D=.5%, C=.25%, B=.1% Optional Fuse: “110C”= 110°C, “167C”=167°C, “187C”=187°C, etc. Leave blank for standard 133°C Termination: W = Lead-free, Q = Tin/Lead (leave blank if either is acceptable) Packaging: B = Bulk (standard) RoHS Term.W is RoHS compliant & 260°C compatible