tfs380a.doc version 3.0 13.03.2001 VI TELEFILTER Filter specification TFS 380A 1/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Measurement Condition Ambient Temperature: 23 °C Input Power Level: 0 dBm Source impedance: 50 Ω Load impedance: 50 Ω Terminating impedances: input: 720 Ω || -4.7pF output: 1000 Ω || -4.1pF Characteristics Remark: Reference level for the relative attenuation a rel is the minimum pass band attenuation a min. It is defined as the insertion loss a e. The nominal frequency fN is fixed to 380,0 MHz. The center frequency f c is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae The given values for the insertion loss, the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below also if the centre frequency f c is shifted due to the temperature coefficient of frequency TC f in the operating temperature range and due to a production tolerance for the centre frequency fc. D a t a typ. Value Limit Insertion Loss ae = amin 14,0 dB max. 17 dB (Reference level) Nominal Frequency fN - 380,0 MHz 1 dB - Bandwidth BW 4,2 MHz min. 4,05 MHz Relative Attenuation arel fN ± 2,5 MHz ... f N ± 3,0 MHz 5 dB min. 3 dB fN ± 3,0 MHz ... f N ± 3,25 MHz 20 dB min. 10 dB fN ± 3,25 MHz ... f N ± 3,5 MHz 35 dB min. 20 dB fN ± 3,5 MHz ... f N ± 5,0 MHz 38 dB min. 30 dB fN ± 5,0 MHz ... f N ± 100,0 MHz 50 dB min. 40 dB Pass Band Ripple fN ± 2,025 MHz 0,4 dB max. 1 dB Group delay ripple ϕ fN ± 2,025 MHz 65 ns max. 100 ns Operating Temperature Range - 0 °C ... + 70 °C Generated: Checked / approved:

tfs380a.doc version 3.0 13.03.2001 VI TELEFILTER Filter specification TFS 380A 2/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Construction and pin connection N11 S 380 A Datecode 50 ΩΩΩΩ test circuit 1,2,5,6,7,8,11,12 Input SAW

4 Output

1 Ground

2 Ground

3 Output RF Return

5 Ground

6 Ground

7 Ground

8 Ground

9 Input RF Return

10 Input

11 Ground

12 Ground

Datecode: Year+week L 1999 M 2000 N 2001 ...

tfs380a.doc version 3.0 13.03.2001 VI TELEFILTER Filter specification TFS 380A 3/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Stability Characteristics: After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 sho cks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: 25 °C to 55°C / 95% r.H. / 10 cycles (cycle) DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing: Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3000 Reel of empty components at start: min 300 mm Reel of empty components at start including leader: min 500 mm Trailer min 300 mm Do Po E F W EMBOSSED CARRIER TAPE COVER TAPE G P 2 Bo Ao Ct Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : 0,6 P2 : 2 ± 0,1 P1 : 8 ± 0,1 D1(min) : 1,5 Ao : 5,5 ± 0,1 Bo : 7,5 ± 0,1 Ct : 13,5+/-0,1 A C N Reel (all dimensions in mm): A : 330 W1 : 16,4 +2 W2 (max) : 22,4 N (min) : 50 C : 13 + 0,5 - 0,2 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close t o the sprocket holes.

tfs380a.doc version 3.0 13.03.2001 VI TELEFILTER Filter specification TFS 380A 4/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 °C over 200 °C 255 °C ± 5 °C Time: 60 sec. - 90 sec. 20 sec. - 25 sec. Air reflow profile 100 120 140 160 180 200 220 240 260 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. temperature / °C Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 0 23 140 160 10 34 150 161 20 46 160 164 30 60 170 170 40 80 180 180 50 103 190 205 60 121 195 230 70 134 200 255 80 143 205 230 90 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120

tfs380a.doc version 3.0 13.03.2001 VI TELEFILTER Filter specification TFS 380A 5/5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. History Version Reason of Changes Name Date Development specification 1.0 new generation Steiner 11.04.2000 2.0 - correction of attenuation specification according to customer needs Steiner 04.08.2000 - stability characteristics, tape and reel dimensions, air reflow profile added Filter specification 3.0 - terminating impedances added Steiner 13.03.2001 - loss definition corrected - typical values added