Filename: tfs 240l.doc Version 1.1 15.07.2004 VI TELEFILTER Filter specification TFS 240L 1/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Measurement condition Ambient temperature TA: 25 °C Input power level: 0 dBm Terminating impedances at fc*: input: 360 Ω // -9,6 pF output: 360 Ω // -10,0 pF Characteristics Remark: Reference level for the relativ e attenuation a rel of the TFS240L is the in sertion loss. The minimum of the pass band attenuation a min is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 25 dB filter attenuation level relative to the insertion loss a e. The temperature coefficient of frequency Tcf is v alid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value tolerance / limit Insertion loss ae 5,2 dB max. 9 dB Centre frequency fc - 240 MHz ± 25 kHz (reference frequency at ambient temperature) Passband Ripple (p-p) fc ± 100 kHz 0,2 dB max. 0,5 dB Relative attenuation a rel Triple transit response suppression 18 dB min. 15 dB Group delay ripple in fc ± 100 kHz 250 ns max. 400 ns Average group delay in fc ± 100 kHz 1,8 µs max. 2,4 µs Return loss in fc ± 150 kHz 12 dB min. 7 dB Input Power Level - max. 20 dBm*) Operating temperature range - - 30 °C.... + 80 °C Storage temperature range - - 40 °C.... + 85 °C Temperature coefficient of frequency TCf -0,04 ppm/K Frequency inversion temperature T0 28 °C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. ) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) *) This power level is allowed for short term operation (10% of life time) only, the max. input power for continuous operation is 15 dBm generated: checked / approved: VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240l.doc Version 1.1 15.07.2004 VI TELEFILTER Filter specification TFS 240L 2/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Filter characteristic Construction and pin connection -90 -80 -70 -60 -50 -40 -30 -20 -10 frequency in MHz m frequency in MHz m agnitude in dB 1.68 1.98 2.28 2.58 2.88 3.18 3.48 3.78 4.08 4.38 frequency in MHz delay in µs (All dimensions in mm)
50 Ohm Test circuit
24,64 ±0, ±0, 2,6 2,3 1,02 1,91 ±0, 3,5 X4,8 10 9 8 7 6 1 2 3 4 5 Date code / batch no. 6 1 10 5 2, 3, 4, 7, 8, 9 10 5 PM246 13/2
- S29 / 01
1 Output
2 Ground
3 Ground
4 Ground
5 Input RF Return
6 Input
7 Ground
8 Ground
9 Ground
10 Output RF Return
Date code: Year + week S 2004 T 2005 U 2006 ... agnitude in dB VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240l.doc Version 1.1 15.07.2004 VI TELEFILTER Filter specification TFS 240L 3/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: DIN IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 1000 reel of empty components at start: min 300 mm reel of empty components at start including leader: min 500 mm trailer min 300 mm So W Do Po Bo Ao E Ct SPEC-Gurt 0061/ 19X6,5 Q09016:02.001 pull off direction view direction X X t Ko X-X Jul.10,01 Tape (all dimensions in mm) W : 44 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 20,25 ± 0,05 G (min) : 0,75 P2 : 2 ± 0,05 P1 : 16 ± 0,1 D1(min) : 2,0 Ao : 9,3 ± 0,1 Bo : 24,9 ± 0,1 CT : 38 ± 0,2 N W W C Reel (all dimensions in mm): A : 330 W1 : 44,4 +2,0 / - W2 (max) : 50,4 N (min) : 100 A The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape in the above shown direction. VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240l.doc Version 1.1 15.07.2004 VI TELEFILTER Filter specification TFS 240L 4/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Air reflow temperature conditions 1st and 2nd air reflow profile Name: pre-heating periods main-heating periods peak temperature Temperature: 150 °C - 170 ° Cover 200 °C 255 °C ± 5 °C T ime: 60 sec. - 90 sec. 20 sec. - 25 sec. Air reflow profile 100 120 140 160 180 200 220 240 260 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. temperature / °C Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. temperature / °C time / sec. temperature / °C 0 23 140 160 10 34 150 161 20 46 160 164 30 60 170 170 40 80 180 180 50 103 190 205 60 121 195 230 70 134 200 255 80 143 205 230 90 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120 VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240l.doc Version 1.1 15.07.2004 VI TELEFILTER Filter specification TFS 240L 5/5 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com History Version Reason of Changes Name Date 1.0 generation of specification Pfeiffer 02.04.2004 1.1 filter characteristic added Pfeiffer 15.07.2004 labelling changed (no. of batch included) VI TELEFILTER reserves the right to make changes to the produc t(s) and/or information contained herein w ithout notice. No liab ility is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.