Description

www.unsemi.com.tw Key Feature Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information.1/3 TFMOV15S Series Thermal Fuse & MOV (TFMOV) Packaging Information Mechanical Data Part Numbering UN Thermal Fuse & MOV (TFMOV) is a new patented product in the field of surge protection. TFMOV is a fail-safe device,which integrated a disk varistor and a Thermal Fuse in a single package. The Thermal Fuse is designed to disconnect the MOV from the circuit, in case of MOV's failure. Because the MOV might thermally run away due to the increasing leakage current, or burn and burst in the event of a short-circuit fault.  Home Electrical Appliances  Telecom Power Supplies  Surge Protectors  Power Adapters  Consuming Electronic  Power Supplies and Solar Energy  Wind Energy  Railway  Optional Remote Signal Function  Space Saving  RoHS & REACH Compliant TFMOV - 15 S XXX - X IT- (1) Thermal Fuse & MOV (2) MOV Size 15 mm (3) TMOV Shape : S—Square (4) Varistor Voltage (5) Level of Limited Current (Refer to UL 1449 3rd clause 39.4) (6) IT—With Remote Signal,Default—Without Remote Signal  unit: mm  Please refer to the specifications for the packaging details.

@1mA dc Clamping Voltage (Max.) Maximum Peak Current (8/20μs) Voltage Clamping Ratio Maximum Energy (Joule) Typical Capacitance (Reference) Thermal Fuse Level of Limited Current B 20A UL60691 E214712 @1kHz (pF)(J) In (V) RclIMax 10/1000μsInIPVCMin. Max.VRMS VDC (V) (V) (V) (V) (A) (KA)(KA) (Ω) Maximum Continuous Operating Voltage Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Thermal Fuse & MOV (TFMOV) Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information. Electrical Characteristics (@25℃ Unless Otherwise Specified ) TFMOV34S Series TFMOV10S330x TFMOV10S390x TFMOV10S470x TFMOV10S560x TFMOV10S680x TFMOV10S820x TFMOV10S101x TFMOV10S121x TFMOV10S151x TFMOV10S181x TFMOV10S201x TFMOV10S221x TFMOV10S241x TFMOV10S271x TFMOV10S301x TFMOV10S331x TFMOV10S361x TFMOV10S391x TFMOV10S431x TFMOV10S471x TFMOV10S511x TFMOV10S561x TFMOV10S621x TFMOV10S681x TFMOV10S751x TFMOV10S821x 115 130 140 150 175 190 210 230 250 275 300 320 350 385 420 460 510 100 125 150 170 180 200 225 250 275 300 320 350 385 415 460 505 560 615 670 108 135 162 185 198 216 243 270 297 324 351 387 423 459 504 558 612 675 738 110 132 165 198 225 242 264 297 330 363 396 429 473 517 561 616 682 748 825 902 110 135 135 165 200 250 300 340 360 395 455 500 550 595 650 710 775 845 925 1025 1120 1240 1355 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 4.6 4.6 4.3 3.8 3.8 3.2 3.2 3.2 3.2 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 108 115 130 140 155 175 180 185 190 200 210 220 6100 5100 4300 3600 2900 2400 2000 1700 1300 1100 1000 900 830 740 670 610 560 510 460 430 390 360 320 290 270 260 VY-2 Series Ur:690Vac; Ir:5A (V)

Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Thermal Fuse & MOV (TFMOV) Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information. Package Dimensions Unit : mm TFMOV34S Series Model Common Dimensions270~121 151~271 331~471 511~621 681~821 911~122 T (±1.0) t (±1.0) (±0.5) 8.0 5.0 5.6 9.0 6.0 6.6 10.2 7.2 7.8 11.4 8.4 9.0 12.6 9.6 10.2 14.0 11.0 11.6 H D L b d 18.0±1.0 17.0±1.0 7.0±1.0 10.5±0.5 Φ0.9±0.05 1.2±0.5 5.4±0.5 14.6±0.5 1.2±0.5 3.0±0.5

Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information. Disclaimer ROHS UNSEMI RESERVES THE RIGHT TO MAKE CHANGE ON OUR PRODUTS , PRODUCTS SPECIFICATION AND DATA WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. UN SEMICONDUCTOR LIMITED its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “UNSEMI”)does not give any representations or warranties for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. In no event shall UNSEMI be liable for any indirect, incidental, punitive, special or consequential damages (including any and all implied warranties, warranties of fitness for particular purpose, non-infringement and merchantability.) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Statements regarding the suitability of products for certain types of applications are based on UNSEMI knowledge of typical requirements that are often placed on UNSEMI products in generic applications. Such statements are not binding, statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify UNSEMI's terms and conditions of purchase, including but not limited to the warranty expressed therein. Unless otherwise agreed in writing, UNSEMI product is not designed, authorized or warranted to be suitable for use in medical life-saving, or life-sustaining application , nor in applications where failure or malfunction of a UNSEMI product can reasonably be expected to result in personal injury, death or severe property or environmental damage. UNSEMI and its suppliers accept no liability for inclusion or use of UNSEMI products in such equipment or applications and therefore such inclusion and/or use is at the customer's own risk. All referenced brands, product names, service names and trademarks are the property of their respective owners.