7.8 .307 .35414 .551

FEATURES

  • High sensitivity: 80 mW Nominal operating power (Single side stable 3-12 V type)
  • Surge voltage withstand: 1500 V FCC Part 68
  • Minimal magnetic interference allows high density mounting
  • Sealed construction allows automatic cleaning
  • Self-clinching terminal also available SPECIFICATIONS Contact Note: g 1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the ac- tual load. Characteristics Remarks * Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section. By resistive method, nominal voltage applied to the coil; contact carrying current: 1 A. Nominal voltage applied to the coil, excluding contact bounce time. Nominal voltage applied to the coil, excluding contact bounce time without diode. Half-wave pulse of sine wave: 11 ms; detection time: 10 m Half-wave pulse of sine wave: 6 ms. Detection time: 10 m Refer to 4. Conditions for operation, transport and storage mentioned in Cautions for use (Page 178). Arrangement 2 Form C Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 50 m W Contact material Gold-clad silver Rating Nominal switching capacity (resistive load)1 A 30 V DC, 0.5 A 125 V AC Max. switching power (resistive load) 30 W, 62.5 VA Max. switching voltage 110 V DC, 125 V AC Max. switching current 1 A Min. switching capacity g 1 10 m A 10 mV DC Nominal operating power Single side stable 80 mW (3 to 12 V DC) 140 mW (24 V DC) 260 mW (48 V DC) 1 coil latching 55 mW (3 to 12 V DC) 100 mW (24 V DC) 2 coil latching 110 mW (3 to 12 V DC) 200 mW (24 V DC) Expected life (min. operations) Mechanical (at 180 cpm) 10 Electrical (at 20 cpm)

1 A 30 V DC resistive load

0.5 A 125 V AC resistive load

Initial insulation resistance* Min. 1,000 M W (at 500 V DC) Initial breakdown voltage Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA) Between contact and coil 1,000 Vrms for 1 min. (Detection current: 10 mA) Between contact sets 1,000 Vrms for 1 min. (Detection current: 10 mA) FCC surge voltage between open contacts 1,500 V Temperature rise* (at 20 C) Max. 50 C Operate time [Set time]* (at 20 C) Max. 4 ms (Approx. 2 ms) [Max. 4 ms (Approx. 2 ms)] Release time [Reset time]* (at 20 Max. 4 ms (Approx. 1 ms) [Max. 4 ms (Approx. 2 ms)] Shock resistance Functional* Min. 490 m/s {50 G} Destructive* Min. 980 m/s {100 G} Vibration resistance Functional* 176.4 m/s {18G}, 10 to 55 Hz at double amplitude of 3 mm Destructive 294 m/s {30G}, 10 to 55 Hz at double amplitude of 5 mm Conditions for oper- ation, transport and storage* (Not freezing and condensing at low temperature) Ambient temperature –40 C to +70 C –40 F to +158 F Humidity 5 to 85% R.H. Unit weight Approx. 2 g .071 oz

ORDERING INFORMATION

Ex. TF 2 L H 3V Contact arrangement Operating function Terminal shape Coil voltage(DC) 2:2 Form C Nil: Standard PC board terminal H: Self-clinching terminal Nil: Single side stable L: 1 coil latching L2: 2 coil latching 3,4.5,5,6,9,12, 24,48*V *48 V coil type: Single side stable only Note: AgPd stationary contact types available for high resistance against contact sticking. When ordering, please add suffix“-3”like TF2-12V-3.

TYPES AND COIL DATA (at 20 C 68 1. Single side stable 2. 1 Coil latching 3. 2 Coil latching Notes: 1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. 2. Standard packing: Tube: 50 pcs.; Case; 1,000 pcs. 3. In case of 5 V drive circuit, it is recommended to use 4.5 V type relay. 4. AgPd stationary contact types available for high resistance against contact sticking. When ordering, please add suffix "-3" like TF2-12V-3. Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) Nominal operating current, mA ( 10%) Coil resistance, W 10%) Nominal operating power, mW Max. allowable voltage, V DC Standard PC board terminal Self-clinching terminal TF2-5 V TF2-H-5 V 5 3.75 0.5 16 312.5 80 7.5 TF2-6 V TF2-H-6 V 6 4.5 0.6 13.3 450 80 9 TF2-12 V TF2-H-12 V 12 9 1.2 6.7 1,800 80 18 TF2-24 V TF2-H-24 V 24 18 2.4 5.8 4,100 140 36 TF2-48 V TF2-H-48 V 48 36 4.8 5.4 8,860 260 57.6 Part No. Nominal voltage, V DC Set voltage, V DC (max.) Reset voltage, V DC (max.) Nominal operating current, mA ( 10%) Coil resistance, W 10%) Nominal operating power, mW Max. allowable voltage, V DC Standard PC board terminal Self-clinching terminal TF2-L-5 V TF2-L-H-5 V 5 3.75 3.75 11 454.5 55 7.5 TF2-L-6 V TF2-L-H-6 V 6 4.5 4.5 9.2 654.5 55 9 TF2-L-9 V TF2-L-H-9 V 9 6.75 6.75 6.1 1,472 55 13.5 TF2-L-12 V TF2-L-H-12 V 12 9 9 4.6 2,618 55 18 TF2-L-24 V TF2-L-H-24 V 24 18 18 4.2 5,760 100 36 Part No. Nominal voltage, V DC Set voltage, V DC (max.) Reset voltage, V DC (max.) Nominal operating current, mA ( 10%) Coil resistance, W 10%) Nominal operating power, mW Max. allowable voltage, V DC Standard PC board terminal Self-clinching terminal TF2-L2-5 V TF2-L2-H-5 V 5 3.75 3.75 22 227.3 110 7.5 TF2-L2-6 V TF2-L2-H-6 V 6 4.5 4.5 18.3 327.3 110 9 TF2-L2-12 V TF2-L2-H-12 V 12 9 9 9.2 1,309 110 18 TF2-L2-24 V TF2-L2-H-24 V 24 18 18 8.3 2,880 200 36 DIMENSIONS mm inch Standard PC board terminal Self-clinching terminal General tolerance: 0.3 .012 .551 7.8 .307 7.1 .280 .354 7.62 .300 3.5 .138 2.54 .100 0.5 .020 0.25 .010 7.8 .307 7.1 .280 7.62 .300 3.5 .138 2.54 .100 0.5 .020 0.25 .010 PC board pattern (Copper-side view) 10.16 .400 7.62 .300 2.54 .100 2.54 .100 10-1.0 dia 10-.039 dia Tolerance: 0.1 .004 Schematic (Bottom view) Single side stable (Deenergized condition) 1-coil latching (Reset condition) 2-coil latching (Reset condition) Direction indication* 10 9 8 7 6 1 2 3 4 5 Direction indication* 10 9 8 7 6 1 2 3 4 5 Direction indication* 10 9 8 7 6 1 2 3 4 5 *Orientation stripe typical-located on top of relay.

  1. Maximum switching capacity 2. Life curve 3. Mechanical life Tested sample: TF2-12V, 10 pcs. 30 100 200 1.0 0.5 0.4 0.3 0.2 Switching voltage,V Switching current, A DC load (cosj=1) AC load (cosj=1) Switching current, A No. of operations, ·10 0 0.5 1.0 100

30 V DC resistive load

125 V AC resistive load

Max. Min. Max. Min. No. of operations, ·10 10 100 1,000 10,000 Ratio against the rated voltage %V 100 Pick-up voltage Drop-out voltage 4.-(1) Electrical life (DC load) Tested sample: TF2-12V, 6 pcs. Condition: 1 A 30 V DC resistive load, 20 cpm Change of pick-up and drop-out voltage Change of contact resistance 4.-(2) Electrical life (AC load) Tested sample: TF2-12V, 6 pcs Condition: 0.5 A 125 V AC resistive load, 20 cpm Change of pick-up and drop-out voltage Max. Min. Max. Min. No. of operations, ·10 Ratio against the rated voltage, %V 05 1 0 100 15 20 Pick-up voltage Drop-out voltage No. of operations, ·10 Contact resistance, mW Max. Min. 05 1 0 100 15 20 Ratio against the rated voltage, %V Max. Min. Max. Min. No. of operations, ·10 100 Pick-up voltage Drop-out voltage Change of contact resistance 5. Coil temperature rise Tested sample: TF2-xxV Measured portion: Inside the coil Ambient temperature: 30 C 86 F 6. Operate/release time characteristics Tested sample: TF2-12V, 5 pcs. No. of operations, ·10 Contact resistance, mW Max. Min. 100 Temperature rise, °C Coil applied voltage, %V Nominal coil voltage 1 A 1 A 0 A 0 100 110 120 130 140 150 1 A 3-12 V DC

24 V DC

48 V DC

Coil applied voltage, %V 0 80 90 100 110 120 Operate/release time, ms Max. Min. Max. Min. Operate time Release time 7. Set/reset time characteristics Tested sample: TF2-L2-12V, 5 pcs. 8. Distribution of pick-up and drop-out voltage Tested sample: TF2-12V, 50 pcs. 9. Distribution of set and reset voltage Tested sample: TF2-L2-12V, 20 pcs. Coil applied voltage, %V 0 80 90 100 110 120 Set/reset time, ms Max. Min. Set time Reset time 01 0 20 30 40 50 60 70 80 90 100 Quantity Ratio against the rated voltage, %V Drop-out voltage Pick-up voltage 20100 30 40 50 60 70 80 90 100 Quantity Ratio against the rated voltage, %V /,/,/, /,/, /,/, /,/, /,/,/,/, /,/,/,/, /,/,/, Set voltage Reset voltage /,/,/, /,/,/,/, /,/,/, /,/, /,/, /,/, /,/,

  1. Ambient temperature characteristics Tested sample: TF2-12V, 5 pcs. 11. Distribution of contact resistance Tested sample: TF2-12V, 30 pcs. (30, 4 contacts)

0 Pick-up voltage

temperature, °C Variation ratio, % –20–40 40 60 80 –10 –20 –30 –40 Contact resistance,mW Quantity 30 40 50 12.-(1) High-frequency characteristics Tested sample: TF2-xxV Isolation characteristics 12.-(2) High-frequency characteristics Tested sample: TF2-xxV Insertion loss characteristics 12.-(3) High-frequency characteristics Tested sample: TF2-xxV V.S.W.R. 100 10 100 1,000 Frequency,MHz Isolation, dB 100 100 1,000 Frequency,MHz Insertion loss, dB 0.2 0.4 0.6 0.8 1.0 Frequency,MHz 1.0 1.2 1.4 1.6 1.8 2.0 10 100 1,000 V.S.W.R. TF Relay V.S.W.R., 50W 13.-(1) Malfunctional shock (single side stable) Tested sample: TF2-12V, 6 pcs 13.-(2) Malfunctional shock (latching) Tested sample: TF2-L-12V, 6 pcs. Y YZ, Z Z X,X X Deenergized condition Energized condition 980m/s 980m/s 980m/s 980m/s 196m/s 980m/s 392m/s 588m/s 784m/s 980m/s Y YZ, Z Z X,X X Reset state Set state 980m/s 980m/s 980m/s 980m/s 980m/s 196m/s 392m/s 588m/s 784m/s 980m/s 14.-(1) Influence of adjacent mounting 14.-(2) Influence of adjacent mounting 14.-(3) Influence of adjacent mounting Inter-relay distance , mm inch .197 –10 –10 10Rate of change, %Rate of change, % ON ON ON OFF OFF OFF Pick-up voltage Drop-out voltage ON ON OFF OFF OFF ON Inter-relay distance , mm inch .197 –10 –10 10Rate of change, %Rate of change, % Drop-out voltage Pick-up voltage OFF ON Inter-relay distance , mm inch .197 –10 –10 10Rate of change, %Rate of change, % Pick-up voltage Drop-out voltageOFF OFF OFF ON ON ON

  1. Actual load test Tested sample: TF2-12V (35 mA 48 V DC wire spring relay load) Circuit Change of pick-up and drop-out voltage Change of contact resistance 500W 500W 0.1 mF 0.1 mF 48 V DC Wire spring relay Circuit diagram No. of operations,·10 Ratio against the rated voltage, %V Max. Min. Max. Min. 10 20 30 40 500 100 Pick-up voltage Drop-out voltage 10 20 30 40 50 Max. Min. No. of operations, ·10 100Contact resistance, mW For Cautions for Use, see Page 178 and 179. 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog