Features

 Meets DoE Efficiency Level VI Requirements  No load input power  Average Efficiency  Up to 20W of AC-DC Power  Universal Input 90-264Vac Input Range  Desktop and Wall-Plug versions  Meets “Heavy Industrial” Levels of EN61000 EMC Requirements  Meets EN55022/CISPR22, and FCC Part

15.109 Class B Conducted & Radiated

Emissions, with 6db margin  Approved to EN/IEC/UL60950-1, 2nd Ed., Am. 2  E-cap life of >10 years  >1,000,000 Hours MTBF  3 Year Warranty  IP22 Rated Enclosure

Description

A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE20A Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, as well as the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE20A series models also meet Class B conducted and radiated emissions per FCC Part 15, EN55022, and CISPR22. These superior performance external power supplies are designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Input Number Volts Current Power Noise¹ Regulation Regulation Connector Configuration TE20A0503F01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class I Desktop, IEC60320 C14 Receptacle TE20A0603F01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703F01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903F01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203F01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1803F01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403F01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803F01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20A0503N01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C8 Receptacle TE20A0603N01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703N01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903N01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203N01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1803N01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403N01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803N01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20A0503Q01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C18 Receptacle TE20A0603Q01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703Q01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903Q01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203Q01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1803Q01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403Q01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803Q01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% LPS

15W-20W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE20 Rev 2.4 12-FEB-16 2 Model Selection (continued) TE20A0503B01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Wall-Plug, Interchangeable Blades (North American Blade included)² TE20A0603B01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703B01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903B01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203B01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A1803B01 18.0V 1.10A 20W 180mV pk-pk ±1% ±5% TE20A2403B01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803B01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% TE20A0503C01 5.0V 3.00A 15W 75mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Wall-Plug, Interchangeable Blades (North American Blade included)² TE20A0603C01 5.9V 2.50A 15W 75mV pk-pk ±1% ±5% TE20A0703C01 7.5V 2.00A 15W 75mV pk-pk ±1% ±5% TE20A0903C01 9.0V 2.00A 18W 90mV pk-pk ±1% ±5% TE20A1203C01 12.0V 1.50A 18W 120mV pk-pk ±1% ±5% TE20A2403C01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A2403C01 24.0V 0.83A 20W 240mV pk-pk ±1% ±5% TE20A4803C01 48.0V 0.42A 20W 480mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1μF ceramic and 47μF low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”. 4. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE20B0503F01). 5. All specifications are typical at nominal input, full load, at 25 °C ambient unless noted. General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 700mS @115Vac, full load Input Current 115Vac: 0.5A, 230Vac: 0.25A Hold-up Time 20mS min., at full Load, 100Vac input Inrush Current 264Vac, cold start: will not exceed 40A Overtemperature Protection Will shutdown upon an overtemperature condition, auto-recovery. Input Fuses F1, F2: 3.15A, 250Vac fuses (line & neutral lines) provided on all models Overload Protection 130 to 180% of rating, Hiccup Mode Earth Leakage Current Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit Protection Hiccup Mode, auto recovery. Efficiency Meets US DoE Efficiency Level VI Average efficiency levels Overvoltage Protection 130 to 150% of output voltage, hiccup mode Output Power 15 to 20W continuous – See models chart for specific voltage model ratings. Isolation Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac No Load Input Power <0.1W per DoE Efficiency Level VI Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Ripple and Noise See models chart on pg 1. Operating Temperature -20°C to +50°C Start Up at -40°C, full load, (warmup period before all parameters are within published specifications). Output Voltage See models chart on pg 1. Temperature Derating Derate output power above 40°C to TBD at 50°C Transient Response 500µs response time, return to within 0.5% of final value for any 50% load step over 5% to 100% of rated load, ∆i/∆t< 0.2A/µs. Max. voltage deviation is +/-3.5%. Storage Temperature -40°C to +85°C Regulation See models chart on pg 1. Altitude Operating: to 5000m. Non-operating: -500 to 40,000 ft. Drop Test 1.4m from table top to wooden platform, 6 faces. Relative Humidity 5% to 95%, non-condensing

15W-20W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE20 Rev 2.4 12-FEB-16 3 Notes: 1. Weight: 110g. 2. All dimensions in mm. 3. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. 4. The unit should not be covered or enclosed to protect against excessive case temperature rise. General Specifications (continued) Vibration Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes; Sine waveform, Vib. frequency/ acceleration: 10-500Hz/1g, sweep rate of 1 octave/min., Vibration time of 10 sweeps / axes, 3 axes Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis E-Cap Life >10 year life, based on calculations at 115Vac/60Hz & 230Vac/50Hz, 25°C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (@80% load for the 12V model) MTBF >1,000,000 hours, full load, 110 & 220Vac input, 25°C amb., per Telcordia 332 Issue 6, Stress Method. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. EMI/EMC Compliance Conducted Emissions: EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A Conducted Disturbances induced by RF Fields EN55022/IEC61000-4-6, 3V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz Voltage Interruptions, Dips, Sags & Surges EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Mechanical Drawing

15W-20W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE20 Rev 2.4 12-FEB-16 4 Connector Information The “03” in the standard model number is replaced by the applicable digits below: Efficiency Level VI Information: Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. TE20A Series