DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

 Meets DoE Efficiency Level VI Requirements  No load input power  Average Efficiency  Up to 120W of AC-DC Power  Universal Input 90-264Vac Input Range  IPX-2 Rated Enclosure for protection against liquid ingress  Meets “Heavy Industrial” Levels of EN61000 EMC Requirements  Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin  Approved to EN/IEC/UL60950-1, 2nd Edition, Am. 2  E-cap life of >7 years  3 Year Warranty  RoHS/REACH Compliant

Description

A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE120 series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Cable Input Number Volts Current Power Noise¹ Regulation Regulation & Connector Configuration TE120A1251F01 12.0V 10.0A 120W 120mV pk-pk ±1% ±5% 4 cond. #18AWG; 6 pin Molex Type conn.2 Class I Desktop, IEC60320 C14 Receptacle x 9.5mm Straight Barrel Type conn., center positiveTE120A2403F01 24.0V 5.00A 120W 240mV pk-pk ±1% ±5% TE120A1251N01 12.0V 10.0A 120W 120mV pk-pk ±1% ±5% 4 cond. #18AWG; 6 pin Molex Type conn.2 Class II Desktop, IEC60320 C8 Receptacle x 9.5mm Straight Barrel Type conn., center positiveTE120A2403N01 24.0V 5.00A 120W 240mV pk-pk ±1% ±5% TE120A1251Q01 12.0V 10.0A 120W 120mV pk-pk ±1% ±5% 4 cond. #18AWG; 6 pin Molex Type conn.2 Class II Desktop, IEC60320 C18 Receptacle x 9.5mm Straight Barrel Type conn., center positiveTE120A2403Q01 24.0V 5.00A 120W 240mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE120B1251F01). 4. All specifications are typical at nominal input, full load, at 25 C ambient unless noted. 5. Other connector options available, contact factory, or visit www.slpower.com.

120W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE120 Rev 1.2 16-MAY-16 PRELIMINARY 2 General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 1 sec @115Vac, full load. Input Current 100Vac: 1.5A, 230Vac: 0.7A Hold-up Time 20mS min., at full Load, 100Vac input Inrush Current 264Vac, cold start: will not exceed 40A peak Overtemperature Protection Will shutdown upon an over-temperature condition, auto-recovery. Input Fuses F1, F2: 3.15A, 250Vac fuses (line & neutral lines) provided on all models Overload Protection 130 to 180% of rating, Hiccup Mode Earth Leakage Current Input-GND: <500μA@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC Short Circuit Protection Hiccup Mode, auto recovery. Efficiency Meets US DoE Efficiency Level VI average efficiency levels Overvoltage Protection 130 to 150% of output voltage (max. 60V on 48V model), hiccup mode Output Power 120W continuous – See models chart for specific voltage model ratings. Isolation Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac No Load Input Power <0.210W per DoE Efficiency Level VI Requirements Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Ripple and Noise See models chart on pg 1. Operating Temperature -20°C to +50°C. Derate above 50 deg C. Output Voltage See models chart on pg 1. Case Temperature Case Temperatures are within regulatory guidelines. Power Supply unit should not be covered or enclosed to ensure proper heat dissipation. Transient Response 500µs response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ∆i/∆t< Temperature Derating See Derating Curve. E-Cap Life >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 12V model) MTBF >250,000 hours, full load, 110 & 220Vac input, 25°C amb., per Telcordia 332 Issue 6. Weight 710g Storage Temperature -40°C to +85°C Safety Drop Test 1.4m from table top to wooden platform, 6 faces. Altitude Operating: to 5000m (derate to TBD temp. above 3000m). Non-operating: -500 to 40,000 ft. Dimensions W: 2.65” x L: 8.3” x H: 1.7” W: 67.4mm x L: 212.4mm x H: 44.25mm Relative Humidity 5% to 95%, non-condensing Vibration Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 50G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis All specifications are typical at nominal input, full load, at 25C ambient unless noted.

120W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE120 Rev 1.2 16-MAY-16 PRELIMINARY 3 EMI/EMC Compliance Conducted Emissions: EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A Conducted Disturbances induced by RF Fields EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Voltage Interruptions, Dips, Sags & Surges EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 Mechanical Drawing (12V Model: Output Connector: 6 pin Molex 39-01-2060 or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC

120W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE120 Rev 1.2 16-MAY-16 PRELIMINARY 4 Mechanical Drawing (18V, 24V models): Output Connector: 2.5 x 5.5 x 9.5mm straight barrel type, center positive. Notes: 1) All dimensions in mm. 2) Other connector options available. See below. 3) The unit should not be covered or enclosed to protect against excessive case temperature rise. Connector Information standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below:

120W Single Output External Power Test & Measurement/Industrial Series www.slpower.com TE120 Rev 1.2 16-MAY-16 PRELIMINARY 5 Deratring Curve: Efficiency Level VI Information: Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. TE120 Series 100 120 140 Output Power (Watts) Ambient Operating Temperature (°C) TE120 Series Derating Curve All Models