© 2016 Littelfuse Protection Relays & Controls Protection Relays Current Monitoring Relays and Transducers www.littelfuse.com/tcs Rev: 1-A-062116 TCS SERIES
Description
The TCS Series is a low cost method of go/no go current detection. It includes a solid-state output to sink or source current when connected directly to a standard PLC digital input module. Its normally open or normally closed output can also be used to control relays, lamps, valves, and small heaters rated up to 1A steady, 10A inrush. The TCS is self-powered (no external power required to operate the unit) and available with an adjustable actuation range of 2 - 20A or factory fixed actuation points from 2 - 45A. Operation Normally Open: When a current equal to or greater than the actuate current is passed through the toroidal sensor, the output closes. When the current is reduced to 95% of the actuate current or less, the output opens. Normally Closed: When the current through the toroid is equal to or greater than the actuate current, the output opens. When the current is reduced below 95% of the actuate current, the output closes. To increase sensitivity, multiple turns may be made through the TCS’s toroidal sensor. The trip point range is divided by the number of turns through the toroidal sensor to create a new range. When using an external CT , select a 2VA, 0-20A output CT rated for the current to be monitored. Select TCS adjustment range 0. Pass one secondary wire lead through the TCS’ toroid and connect the secondary leads together. Features & Benefits FEATURES BENEFITS Self powered No control voltage is required to operate the unit T otally solid state and encapsulated No moving parts to arc and wear out over time and encapsulated to protect against shock, vibration, and humidity Can connect directly to PLC Solid state output to sink or source current can be connected directly to a standard PLC digital input module 1A steady, 10A inrush solid-state output Provides 100 million operations in typical conditions Complete isolation between sensed current and control circuit Allows you to monitor a load in a separate lectrical system Current Sensor Wiring Diagram
Ordering Information
MODEL OUTPUT VOLTAGE ACTUATE CURRENT OUTPUT FORM MODEL OUTPUT VOLTAGE ACTUATE CURRENT OUTPUT FORM TCSG2A 3 to 50VDC Fixed, 2A Normally open TCSH2B 24 to 240VAC Fixed, 2A Normally closed TCSGAA 3 to 50VDC 2-20A adjustable Normally open TCSH5B 24 to 240VAC Fixed, 5A Normally closed TCSGAB 3 to 50VDC 2-20A adjustable Normally closed TCSHAA 24 to 240VAC 2-20A adjustable Normally open TCSH2A 24 to 240VAC Fixed, 2A Normally open TCSHAB 24 to 240VAC 2-20A adjustable Normally closed If you don’t find the part you need, call us for a custom product 800-843-8848 Monitored AC conductor must be insulated. N/L2 N/L2 N/L2 L = Load V = Voltage PS = Power Supply PLC = PLC Digital Input Module POSITIVE SWITCHING SINKING SOURCING NEGATIVE SWITCHING N/L2
© 2016 Littelfuse Protection Relays & Controls Protection Relays Current Monitoring Relays and Transducers www.littelfuse.com/tcs Rev: 1-A-062116 TCS SERIES Accessories P1023-6 Mounting bracket The 90° orientation of mounting slots makes installation/removal of modules quick and easy. P1015-64 (AWG 14/16) Female Quick Connect These 0.25 in. (6.35 mm) female terminals are constructed with an insulator barrel to provide strain relief. P1015-18 Quick Connect to Screw Adapter Screw adapter terminal designed for use with all modules with 0.25 in. (6.35 mm) male quick connect terminals. C103PM (AL) DIN Rail 35 mm aluminum DIN rail available in a 36 in. (91 .4 cm) length. P1023-20 DIN Rail Adapter Allows module to be mounted on a 35 mm DIN type rail with two #10 screws. Function Diagram Specifications Sensor Type Toroid, through hole wiring, alternating current, monitored wire must be properly insulated Current to Actuate Adjustable: - 2 - 20A, guaranteed range Reset Current ≅ 95% of the actuate current Maximum Allowable Current Steady - 50A turns Inrush - 300A turns for 10s Actuate Current vs. Temp. & Voltage ≤ ±5% Response Times Overcurrent - ≤ 200ms Undercurrent - ≤ 1s Burden < 0.5VA Output Type Solid state Form NO or NC Rating 1A steady, 10A inrush Voltage AC - 24 to 240VAC +10/-20% DC - 3 to 50VDC Voltage Drop AC NO & NC - ≅ 2.5V DC NO & NC - ≅ 1.2V Protection Circuitry Encapsulated Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface Insulation Resistance ≥ 100 MΩ Mechanical Mounting Surface mount with one #10 (M5 x 0.8) screw Dimensions H 50.8 mm (2”); W 50.8 mm (2”); D 44.5 mm (1.75”) Termination 0.25 in. (6.35 mm) male quick connect terminals (2) Sensor Hole 0.36 in. (9.14 mm) for up to #4 AWG (21.1 mm2) THHN wire Environmental Operating/Storage Temperature -20° to 60°C / -40° to 85°C Humidity 95% relative, non-condensing Weight ≅ 2.6 oz (74 g) TP = Trip Point OC = Monitored Current NO = Normally Open Output NC = Normally Closed Output R = Reset