TECHNOLOGY DYNAMICS INC. AVAILABLE OPTIONS Design Excellence since 1976! SPECIFICATIONS TD RSP-1URK-BBU SERIES
1000 WATT DC-UPS
BATTERY BACK-UP POWER SUPPLY INPUT SPECIFICATIONS: ENVIRONMENTAL SPECIFICATIONS Input: Universal AC Input Range 90-264VAC Input Frequency: 47-63Hz (400Hz Optional) Inrush Cur rent: 25A max at 115VAC/40A at 230 VAC (cold start) Input Current: 12 A max @ 115VAC 6A max @ 230VAC Efficiency: 83-90% typical (depending on output model) Hold-up time: 16ms at full load (minimum) Leakage Current: <2.0mA maximum @ 240 VAC Harmonics: EN 61000-3-2, -3 Class D Compliant (0.99 PF Typical) Operating Temperature: -20°C to +50°C. Der ate to 50% at +70°C Storage Temperature: -40°C to + 85°C max 95 % Relative Humidity Cooling: Internal ball bearing DC fan Humidity: 20-90% RH non condensing Vibration: 10-500Hz, 2G 10min/1cycle for 60 min (3 axes) Shock: 20G Peak Acceleration Weight: Approx: 22 LBS Size: 1.75” x 19” x 13.5” The TD RSP-1URK-BBU Series of Battery back-up Power Supplies satisfies a growing market where critical continuous power is required. Designed as a complete system with power supplies and batteries it is ideal for medical, industrial and critical process control applications where no down time can be tolerated. OUTPUT SPECIFICATIONS Adjustment Range: ± 10% (minimum) Minimum Load: none Regulation: Line±0.5% Load ±0.5% Ripple/Noise: 150mV peak to peak maximum (20 MHz) Set Point Accuracy: ± 1%(except 5V=±2%) (maximum) Output voltage adj: ±10% minimum Overcurrent Protection: 105-125% automatic recovery Constant Current Overlvoltage Protection: 115 -140% of V1 nominal Overtemperature Protection: Heatsink Temp. 90 °C ± 5°C Auto Recovery STANDARD FEATURES
APPLICATIONS
- Universal AC Input/Full range
- Active PFC for EN61000-3-2,-3
- Built In Batteries
- Current Share Function
- DC Good Signals
- Remote on/off & Remote Sense Functions
- Low Voltage Battery Disconnect
- Parallel Operation
- ORing Diode for Redundant Operation
- Digital Meters
- Ruggedized for shock & vibration
- 400Hz Operation
- Conformal Coating SAFETY AND EMISSIONS
- Designed to meet UL/cUL60950-1
- Designed to meet TUV EN60950-1
- Designed to meet CB Report (IEC 60950-1)
- Designed to meet CE Mark (LVD)
- Designed to meet EN55022 Class B (CISPR 22 B) File: A5269 1U LOW RACK HEIGHT SPECIFICATIONS INPU T SPECIFIC A TIONS: A A y g s r s 1U LOW RACK HEIGHT SPECIFICATIONS
NOTE: SEPARATE POWER SUPPLY RACKS AND DRAWS ARE AVAILABLE FOR INCREASED POWER LEVELS AND BACK-UP TIMES MINIMUM QUANTITY PURCHASE REQUIRED ON MOST MODELS. OTHER VOLTAGES & CURRENTS ARE AVAILABLE CONTACT THE FACTORY FOR DETAILS. MODEL SELECTION division of APPLIED POWER CONVERSION TECHNOLOGY DYNAMICS INC.
100 School Street, Bergenfield, NJ 07621
Phone: (201) 385-0500, Fax: (201) 385-0702 W ebsite: www .theallpower .com SPECIFICA TIONS ARE SUBJECT T O CHANGE WITHOUT NOTICE MECHANICAL OUTLINE MODEL MODEL
600 WATT POWER SUPPLY 800 WATT POWER SUPPLY
800 WATTS BACK-UP FOR 8 MIN600 WATTS BACK-UP FOR 11 MIN
(13.5V) @ 50A TDRSP-1URK-BBU-24-25 TDRSP-1URK-BBU-48-12 24V (27.6V) @ 25A 48V (54V) @ 12A TDRSP-1URK-BBU-24-66 12V (27.6V) @ 66A TDRSP-1URK-BBU-24-33 TDRSP-1URK-BBU-48-16 24V (27.6V) @ 33A 48V (54V) @ 16A MODEL
1000 WATT POWER SUPPLY
1000 WATTS BACK-UP FOR 5 MIN
(27.6V) @ 41A 48V (54V) @ 20A