TCL200 ETC1 | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
LMSHELF = Mounting Shelf 300-450W MXSHELF = Mounting Shelf 72-200W C1063R4 9/02 IH General Description The CCL/TCL Series provides functional emer- gency lighting in a variety of wattages up to 450 watts. High performance electronics and rugged 18 gauge steel construction ensure long-term life safety reliability. Illumination Illumination is accomplished with up to three lamp heads mounted on the top of the unit. The most popular lamp head for use with the CCL/TCL Series is the “D” Series round sealed beam Par 36 tungsten lamp head. The “D” head is available up to 30 watts. CCL/TCL Series High Capacity Steel Emergency Lighting Units 6 and 12 Volt, 75 to 450 Watts Wet Cell Lead Calcium Battery Housing Constructed of 18 gauge steel with a tan epoxy powder coat finish. Knockouts provided for mounting up to three lamp heads. Bi-color LED charge monitor/indicator and a “press-to test” switch are located on the front of the cabinet. Choice of wedge base, sealed beam tungsten, or halogen lamp heads Electronics 120/277 VAC dual voltage input with surge-protected, solid-state circuitry provides for a reliable charging system. Charging system is complete with low voltage disconnect, AC lockout, brownout protection, AC indicator lamp and test switch. Includes two fused output circuits. Utilizes a fully automatic voltage regulated two-rate cur- rent limited solid-state charger -- initially provides a high rate charge upon restoration of AC power, and provides trickle charge to maintain batteries at full capacity once float voltage is attained. Optional ACCU-TEST Self Diagnostics includes an auto- matic 3 minute discharge test every 30 days. A manual test is available from 1 to 90 minutes. Warranty Three year full electronics warranty One year full plus four year prorated battery warranty Battery Low maintenance, free electrolyte, wet cell, lead calcium battery Specific gravity disk indicators show relative state charge at a glance Operating temperature range of battery is 65°F Battery supplies 90 minutes of emergency power Code Compliance UL 924 listed NFPA 101 NEC BOCA and OSHA illumination standard Performance Input power requirements 120 VAC - 0.66 amps, 80 watts 277 VAC - 0.30 amps, 80 watts Dimensions TYPE: CATALOG NO.: Shown: CCL150DL2
Ordering Information
SERIES DC LAMP # OF FACTORY INSTALLED WATTAGE HEADS HEADS OPTIONS 1 CCL = 6 Volt 6 V olt 6 Volt 3 = Three A = Ammeter 2 TCL = 12 Volt 75 = 75 Watts DY = 8 Watt, Tungsten 2 = Two ACF1 = 120 VAC Fuse 100 = 100 Watts DA = 18 Watt, Tungsten 1 = One ACF2 = 277 VAC Fuse 150 = 150 Watts DL = 25 Watt, Tungsten ACP1 = 120 VAC Power Switch 225 = 225 Watts DC = 30 Watt, Tungsten ACP2 = 277 VAC Power Switch AD = ACCU-TEST Self-Diagnostics 12 V olt (Includes standard voltmeter) 12 Volt ADAL = ACCU-TEST with Alarm 150 = 150 Watt DNY = 12 Watt, Tungsten ADTD = ACCU-TEST with Time Delay 3 200 = 200 Watt DE = 28 Watt, Tungsten DCP = DC Power Switch 300 = 300 Watt DK = 25 Watt, Tungsten EX = Special Input Transformer (Specify voltage and frequency) 450 = 450 Watt DG = 30 Watt, Tungsten TD1 = 120 VAC Time Delay 3 TTD2 = 277 VAC Time Delay 3 (Suggested lamp heads listed V = Voltmeter 2 above. Refer to the Accessories Section for W = White Housing additional lamp head choices.) CCL 150 DL 2 TD1 16.0” (40.6 cm) TCL300, TCL450 CCL75, CCL100, CCL150, CCL225, TCL150, TCL200 6.0” (15.2 cm) 7.6” (19.3 cm) 12.0” (30.5 cm) 27.0” (12.7 cm) 6.0” (15.2 cm) 7.6” (19.3 cm) 12.0” (30.5 cm) Notes: 1) Some option combinations may impact UL list- ing. consult factory for specifics. 2) Not available witj AD, ADAL, or ADTD options. 3) 15 minute delay.
18 gauge steel housing with a tan epoxy powder coat finish. Knockouts provided for mounting up to three lamp heads. The suggested lamp head is the “D” Series round sealed beam Par 36 tungsten. To order lamp heads other than the suggested “D” head, refer to Chloride Accessories Section.. Self-Diagnostics The ACCU-TEST Self-Diagnostics option conducts automatic and manual tests, and indicates real time status of the lamp, battery and charger via LED indica- tor lamps. Automatic tests include: Systems analysis every 10 seconds, with actual load tests performed for a 3 minute duration every 30 days. A manual tests is available from 1 to 90 minutes. Battery Low maintenance, free electrolyte, wet cell, lead calci- um battery. Standard sustained emergency operation is for 90 minutes with the illumination source providing full light output. The suggested operating temperature range for lead calcium batteries is 65°F (19°C) to 85°F (30°C) and should provide a service life of 5 years. Performance Input power requirements 120 VAC - 0.66 amps, 80 watts 277 VAC - 0.30 amps, 80 watts Code Compliance The CCL/TCL Series meets or exceeds all performance standards as required by UL 924, NFPA 70, NFPA 101, NEC and OSHA. Specification Data for CCL/TCL Series Steel Emergency Lighting Units Suggested Specification Furnish and install Chloride Systems emergency lighting unit model ________. The unit shall be constructed to meet Underwriter ’s Laboratories, Inc. Standard #924 and the National Electrical Code (NEC). INSTALLATION AND OPERATION - Unit shall be easily field connected to a 120 or 277 VAC, 60 hertz, unswitched power source. Installation must comply with the NEC as well as other applicable codes. Upon utility power failure or brownout, the unit shall automatically transfer to batter y power and maintain the required illumina- tion level for a minimum period of 90 minutes. Upon restoration of utility power, the charger shall restore the battery to ful l charge within UL 924 requirements follow- ing a rated discharge of not more than 90 minutes. CHARGER - Product shall utilize a fully automatic, voltage regulated, two-rate current limited solid-state charger. The charging system shall maintain the battery at full capacity without the need for periodic exercising or equalization. The following features shall be standard: Low voltage disconnect (LVD), brownout protection and AC lockout. BATTERY - The battery shall be a low maintenance, free electrolyte, wet cell, lead calcium battery. The lead calcium battery shall provi de trouble-free operation in temperatures up to 85°F (30°C). HOUSING - The unit housing shall be constructed of 18 gauge steel with a tan epoxy powder coat finish. Chloride Systems ISO 9001A2528 C1063R4 9/02 IH
272 West Stag Park Service Road • Burgaw NC 28425
Telephone: (910) 259 1000 • Facsimile: (800) 258 8803 www.chloridesys.com Lamp Head Photometrics (For DL, suggested head for CCL) (For DK, suggested head for TCL) Operation DC Suggested Watts to 87 1⁄2 Voltage Unit Lamp Head of Rated Voltage* 11⁄2 hrs. 2 hrs. 4 hrs. 8 hrs. 6 CCL75 DL 75 56 28.5 15 CCL100 DL 100 75 38 20 CCL150 DL 150 112.5 57 30 CCL225 DL 225 169 85.5 45 12 TCL150 DK 150 112.5 57 30 TCL200 DK 200 150 96 34 TCL300 DK 300 225 114 60 TCL450 DK 450 337.5 171 90 Electronics 120/277 VAC dual voltage input with surge-protect- ed, solid-state charging circuitry provides for a reliable charging system. The charging system is furnished with low voltage disconnect, AC lockout, brownout protection, AC indicator lamp and test switch. The low voltage disconnect (LVD) feature will dis- connect the battery prior to an unacceptable deep discharge, but not before the required 90 minute emergency operation. The AC lockout feature prevents battery drain prior to the initial energizing of utility power, and allows the installer to complete all wiring and electrical connec- tions without energizing the emergency circuit. The brownout protection circuitry will automatically switch the unit into the emergency mode if the utility voltage sags below 20% of nominal. Battery charging circuitry is entirely solid-state, and utilizes a fully automatic, voltage regulated charger. Battery recharge time after full discharge is less than the required UL 924 standard. Line sensitive electronics cause an instantaneous transfer to battery power if utility power is lost, or a brownout condition is detected. When line voltage is present and stabilized, the transfer circuitry switches back to normal operation and begins recharging the battery. The transfer circuitry can be tested via a momentary test switch located on the housing. Vertical 20 30 50100 Up 20 feet 0 Down 20 .2 .1 40 60 70 .31 .5 Horizontal 20 30 50100 Left 20 feet 0 Right 20 .2 .1 40 60 70 .31 .5 20 30 50100 Up 20 feet 0 Down 20 Photometric No. 3 40 60 70 80 1 .3 .2 .1.5 Horizontal 20 30 50100 Left 30 feet 0 Right 30 1 .3 .2 .1 40 60 70 80