TCB AVX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

The TCB series is a COTS-Plus version of the professional grade TCR polymer series.

FEATURES

  • Robust design for long operation lifetime
  • Statistical screening with Accelerated Ageing
  • Surge testing level option
  • Improved basic reliability 0.5%/1000hrs
  • Humidity 85°C/85%RH, Vr, 500/1000 hours
  • - 55 to +125°C operation temperature
  • Shock and Vibration by MIL-STD-202
  • DCL 0.1 CV
  • 3x reflow 260°C compatible
  • Benign failure mode under recommended use conditions

APPLICATIONS

Long life time DC/DC converter applications in Telecommunications, Industrial, Avionics. L SA A W1 W H XXXXX 106 V AVX LOGO Polymer Capacitance Value in pF 106 = 10µF Rated Voltage V = 35V ID Code Polarity Band (Anode+) CASE DIMENSIONS: millimeters (inches) Code EIA Code EIA Metric L±0.20 (0.008) W+0.20 (0.008) -0.10 (0.004) H+0.20 (0.008) -0.10 (0.004) W1±0.20 (0.008) A+0.30 (0.012) Y 2917 7343-20 7.30 (0.287) 4.30 (0.169) 2.00 (0.079) max W1 dimension applies to the termination width for A dimensional area only. CAPACITANCE AND RATED VOLTAGE, VR (VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE) Capacitance Rated Voltage µF Code 2.5(e) 4V(G) 6.3V(J) 10V(A) 16V(C) 20V(D) 25V(E) 35V(V) 10 106 D(70) 15 156 D(70) 22 226 B(70) B(70) D(70) 68 686 B(70) D(70) D(70) 100 107 B(70) B(70) D(55) 150 157 D(40) D(55) 330 337 D(40) D(40) 470 477 D(40) LEAD-FREE COMPATIBLE COMPONENT For RoHS compliant products, please select correct termination style. MARKING B, D, Y CASE Released Ratings (ESR ratings in mOhms in parentheses) Note: Voltage ratings are minimum values. AVX reserves the right to supply higher voltage ratings in the same case size to the same reliability standards TCB Series COTS-Plus Polymer Capacitor 070119

Technical Data: All technical data relate to an ambient temperature of +25ºC Capacitance Range: 10μF to 470μF Capacitance Tolerance: ±20% Leakage Current DCL: 0.1CV Temperature Range: -55ºC to +125°C Basic Reliability: 0.5% per 1000 hours at 85ºC, Vr with 0.1ΩV series impedance, 60% confidence level Termination Finish: Sn Plating or SnPb Plating (Non RoHS) HOW TO ORDER AVX PART NUMBER: TCB 107 010D C S Z 0 E++^RM Type Case Size See table on previous page Capacitance Code pF code: 1st two digits represent significant figures 3rd digit represents multiplier (number of zeros to follow) Tolerance M = ±20% Rated DC Voltage 002 = 2.5Vdc 004 = 4Vdc 006 = 6.3Vdc 010 = 10Vdc 016 = 16Vdc 020 = 20Vdc 025 = 25Vdc 035 = 35Vdc Inspection Level S = Standard Conformance Reliability Grade Z = Non-ER Termination Finish 7 = 100% Tin H* = Sn/Pb Non RoHS *Contact Manufacturer Surge Test Option 00 = Standard 23 = 10x Cycles, 25°C 24 = 10x Cycles, -55ºC & +85ºC Qualification Level 0 = N/A Additional Character E = Black resin ESR C = Std ESR L = Low ESR Packaging R = 7” T&R NOTE: Conductive Polymer Capacitors are designed to operate within the limits of the environmental conditions specified for each series. If operated continuously at their maximum temperature and / or humidity limit, or beyond these limits, capacitors may exhibit a parametric shift in capacitance and increases in ESR. These changes may occur earlier if the specified environmental conditions are exceeded. Similarly, their normal operational time period will be significantly extended if their general duty cycle includes operation below maximum temperature within humidity controlled environments. Careful attention should be paid to maximum temperature with associated high humidity environments as well as voltage derating, ripple current and current surges. Please reference the AVX Conductive Polymer Capacitor Guidelines for more information or contact factory for application assistance. TCB Series COTS-Plus Polymer Capacitor 050719

RATINGS & PART NUMBER REFERENCE AVX Part No. Case Size Capacitance (μF) Rated Voltage (V) Maximum Operating Temperature (ºC) DCL Max. (μA) DF Max. (%) ESR Max. @ 100kHz (mΩ) 100kHz RMS Current (mA) MSL Humidity 85ºC/ 85%RH, Vr (hrs)45ºC 85ºC 105ºC 125ºC

2.5 Volt

TCBB107M002CRSZ0^++E B 100 2.5 125 25 8 70 1300 900 600 300 3 1000

4 Volt

TCBB107M004CRSZ0^++E B 100 4 125 40 8 70 1300 900 600 300 3 1000 TCBD227M004CRSZ0^++E D 220 4 125 88 8 40 2400 1700 1100 600 3 1000 TCBY227M004CRSZ0^++E Y 220 4 125 88 8 40 2200 1500 1000 600 3 500 TCBD337M004CRSZ0^++E D 330 4 125 132 8 40 2400 1700 1100 600 3 1000 TCBD477M004CRSZ0^++E D 470 4 125 188 8 40 2400 1700 1100 600 3 1000

6.3 Volt

TCBB226M006CRSZ0^++E B 22 6.3 125 13 8 70 1300 900 600 300 3 1000 TCBB336M006CRSZ0^++E B 33 6.3 125 19 8 70 1300 900 600 300 3 1000 TCBB476M006CRSZ0^++E B 47 6.3 125 28 8 70 1300 900 600 300 3 1000 TCBB686M006CRSZ0^++E B 68 6.3 125 40.8 8 70 1300 900 600 300 3 1000 TCBD157M006CRSZ0^++E D 150 6.3 125 90 8 40 2400 1700 1100 600 3 1000 TCBD227M006CRSZ0^++E D 220 6.3 125 132 8 40 2400 1700 1100 600 3 1000 TCBD337M006CRSZ0^++E D 330 6.3 125 198 8 40 2400 1700 1100 600 3 1000

10 Volt

TCBB226M010CRSZ0^++E B 22 10 125 22 8 70 1300 900 600 300 3 1000 TCBB336M010CRSZ0^++E B 33 10 125 33 8 70 1300 900 600 300 3 1000 TCBB476M010CRSZ0^++E B 47 10 125 47 8 70 1300 900 600 300 3 1000 TCBD686M010CRSZ0^++E D 68 10 125 68 8 70 1800 1300 800 500 3 1000 TCBD107M010CRSZ0^++E D 100 10 125 100 8 55 2000 1400 900 500 3 1000 TCBD157M010CRSZ0^++E D 150 10 125 150 8 55 2000 1400 900 500 3 1000 TCBD227M010CRSZ0^++E D 220 10 125 220 8 35 2500 1800 1100 600 3 1000

16 Volt

TCBD336M016CRSZ0^++E D 33 16 125 52 8 70 1800 1300 800 500 3 1000 TCBD476M016CRSZ0^++E D 47 16 125 75 8 65 1900 1300 900 500 3 1000 TCBD686M016CRSZ0^++E D 68 16 125 109 8 70 1800 1300 800 500 3 1000

20 Volt

TCBD226M020CRSZ0^++E D 22 20 125 44 8 70 1800 1300 800 500 3 1000 TCBD336M020CRSZ0^++E D 33 20 125 66 8 70 1800 1300 800 500 3 1000 TCBD476M020CRSZ0^++E D 47 20 125 94 8 70 1800 1300 800 500 3 1000

25 Volt

TCBD156M025CRSZ0^++E D 15 25 125 37 8 70 1800 1300 800 500 3 1000

35 Volt

TCBD106M035CRSZ0^++E D 10 35 125 35 8 70 1800 1300 800 500 3 1000 RECOMMENDED DERATING FACTOR Voltage and temperature derating as percentage of Vr. Rated voltage Operating Temperature ≤85°C 105°C 125°C ≤10V 90% 90% 60% ≥16V 80% 80% 54% For Vr ≤ 10V For Vr ≥ 16V Recommended Application Voltage 100% 95% 90% 85% 80% 75% 70% 65% 60% 55% 50% -55% 85ºC 105ºC 125ºC 67% 60% Recommended Application Voltage Rated VoltageRated Voltage 100% 95% 90% 85% 80% 75% 70% 65% 60% 55% 50% -55% 85ºC 105ºC 125ºC 67% 54% TCB Series COTS-Plus Polymer Capacitor 030719

TEST TCB series (Temperature range -55ºC to +125ºC) Condition Characteristics Endurance Determine after application of rated voltage for 2000 +48/-0 hours at 105±2ºC. Also determine after application of 125ºC temperature, 2/3 rated voltage for 2000 +48/-0 hours. After test leaving 1-2 hours at room temperature. Power supply impedance to be ≤ 0.1Ω/V. Visual examination no visible damage DCL 1.25 x initial limit ΔC/C within +10/-20% of initial value DF initial limit ESR 2 x initial limit Storage Life 125ºC, 0V, 2000h Visual examination no visible damage DCL 2 x initial limit ΔC/C within +10/-20% of initial value DF initial limit ESR 2 x initial limit Biased Humidity Determine after leaving for 500 or 1000 hours at 85±2ºC, 85% relative humidity and rated voltage and then recovery 1-2 hours at room temperature. Visual examination no visible damage DCL 3 x initial limit ΔC/C within +35/-5% of initial value DF initial limit ESR 2 x initial limit Temperature Stability Step Temperature°C Duration (min) 1 +20±2 15 2 -55+0/-3 15 3 +20±2 15 4 +85+3/-0 15 5 +125+3/-0 15 6 +20±2 15 +20ºC -55ºC +20ºC +85ºC +125ºC +20ºC DCL IL* n/a IL* 10 x IL* 12.5 x IL* IL* DF IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL* Surge Voltage Test temperature: 125ºC+3/0ºC Surge voltage: 1.3 x2/3 rated voltage Charge/Discharge resistance: 1000±100Ω Number of cycles: 1000x Cycle duration: 6min; 30 sec charge, 5min 30 sec discharge Visual examination no visible damage DCL initial limit ΔC/C within +5/-20% of initial value DF initial limit ESR 1.25 x initial Limit Mechanical Shock/Vibration MIL-STD-202, Method 213, Condition I,

100 G peak

MIL-STD-202, Method 204, Condition D,

10 Hz to 2,000 Hz, 20 G peak

Visual examination no visible damage DCL initial limit ΔC/C within ±10% of initial value DF initial limit ESR 1.25 x initial Limit *Initial Limit For use outside of recommended conditions and special request, please contact manufacturer. Initial measurement max. 1hr after the removal from dry pack or after pretreatment at 85°C for 24 hours. TCB Series COTS-Plus Polymer Capacitor 011519