Features

  • Low Magnetic Radiation
  • Low Core Loss
  • High current capacity up to 10A Electrical Inductance Range: 10µh to 1000µh Additional values available Tolerance: 15% over entire range ( )TC210- 100L-RC ( )TC210-120L-RC ( )TC210-150L-RC ( )TC210-180L-RC ( )TC210-220L-RC ( )TC210-270L-RC ( )TC210-330L-RC ( )TC210-390L-RC ( )TC210-470L-RC ( )TC210-560L-RC ( )TC210-680L-RC ( )TC210-101L-RC ( )TC210-121L-RC ( )TC210-151L-RC ( )TC210-181L-RC ( )TC210-221L-RC ( )TC210-271L-RC ( )TC210-331L-RC ( )TC210-391L-RC ( )TC210-471L-RC ( )TC210-561L-RC ( )TC210-681L-RC ( )TC210-821L-RC ( )TC210-102L-RC Allied Part Number Inductance (µH) L(µH) I rated IDC (A) DIM (Nom) 100 121 150 180 220 270 330 390 470 560 680 820 1000 10.8 10.3 7.7 7.4 7.0 5.3 5.0 4.8 3.6 3.4 3.3 2.4 2.2 3.4 2.6 2.4 1.8 1.7 1.7 1.6 1.5 1.4 1.4 1.3 .77 .77 .76 .76 .76 .75 .75 .75 .75 .75 .75 .74 .74 .79 .77 .77 .76 .76 .76 .76 .79 .79 .79 .81 .053 .053 .042 .042 .042 .034 .034 .034 .027 .027 .027 .022 .022 .034 .027 .027 .022 .022 .022 .022 .022 .022 .022 .022 Please sp ecify Vertical or Hor izontal Mount by placing a V or H at the beginning o f the part number, i.e. VTC210- 100L (Vertical Mount). A ll specificat ions subject to change without notice. DCR (Ω) 6.3 7.4 10.2 11.9 14.2 19.1 22.8 26.4 34.7 40.6 48.3 75.2 88.5 84.3 113.1 134.4 181.6 216.3 250.1 293.8 341.5 403.2 472.8 559.2 .34 .34 .33 .33 .33 .32 .32 .32 .31 .31 .31 .31 .31 .35 .34 .34 .33 .33 .33 .35 .35 .35 .35 .37 .006 .007 .012 .013 .015 .026 .029 .032 .055 .060 .067 .130 .150 .062 .110 .120 .210 .230 .250 .280 .300 .330 .370 .400 Tolerance (%) Toroidal Chokes TC210 ALLIED COMPONENTS INTERNATIONAL714-665-1 140 www.a lliedcom ponen ts.com RoHS Vertical Mount Horizontal Mount 0.45 (11.43)MAX A BC 0.86 (21.84)MAX Dimensions: Inches (mm) Tin lead to coil 0.50 (12.70)
  • Available in Horizontal or Vertical configuration
  • Optional Tape Cover Test Frequency: 1KHz Operating Temp: -55ºC ~ +105ºC Temp Rise: ∆ T=30ºC Typical at rated IDC Part temperature should not exceed 125ºC including temperature rise. Test Equipment (L): 100 LCR meter or equivalent DCR: Chen Hwa 502 Physical Packaging: Bulk Marking: None REVISED 6/25/10 @ 1KHZ MAX A DIM (Nom) B DIM (Nom) C
  • Cross to Miller / Bourns 2100