Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltd en 8.105.900.01 Technical features Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 17 bar (246 psi) Outlet pressure ranges: Filter element: 40 μm Port size: G1/4, G3/8, 1/4 PTF, 3/8 PTF Gauge: Integrated as standard Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0.35 bar (5 psi) Bowl pressure required to open drain: ≤ 0.2 bar (2.9 psi) Minimum air flow required to close drain: 1 dm³/s. Ambient/Media temperature: Polycarbonat bowl: Metal bowl: Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Atex: T82 + B82 are in conformity with Atex 2014/34/EU II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db Materials: Body: Die cast aluminum Body covers: ABS Bonnet: Acetal Valve: PP with Geolast seals Transparent Bowl: Polycarbonate with Polypropylene Guard. Metal Bowl: Die cast Zinc with PA liquid level indicator lens Filter element: sintered PP Bowl ‘o’- ring: Chloroprene Elastomers: NBR Technical data TB82 - standard models *1) All models shown here are supplied with guarded transparent bowl, brackets and integrated gauge applicable for flow direction left to right With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren Symbol Port Size Shutoff Valve Drain Weight (kg) Model *1) G1/4 With Manual 0,7 TB82-221G G3/8 With Manual 0,7 TB82-321G G1/4 With Auto 0,7 TB82-201G G3/8 With Auto 0,7 TB82-301G In addition to the standard box set units shown on this data sheet, further combinations can be configured using our online Air Preparation configurator: www.norgren.com/air-preparation-configurator > Port size: 1/4“ & 3/8” (ISO G/PTF) > Unique Quikclamp connection system offers full modularity > 40 micron particle and high efficiency water removal (> 95%) > Double safety lock on bowl > Shut off valve & Filter- Regulator with tamper resistance feature > Metal bowl with prismatic liquid level indicator > Light weight polycarbonate bowl > High Corrosion resistance: Body and Metal bowl with Electrophoretic Paint finish > Easy to read flush mounted integrated pressure gauge as standard DoC in accordance with 2014/34/EU/ATEX TB82 - Filter-Regulator – Combination Excelon® Plus Modular System
2.0 4.0 6.0 8.0 1.0 3.0 5.0 7.0 AIR FLOW 0 10 20 30 40 OUTLET PRESSURE 2.0 4.0 6.0 8.0 1.0 3.0 5.0 7.0 II 2 GD Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltden 8.105.900.02 TB82– H H 1 HOption selector *1) *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren Port size Substitute 1/4" 2 3/8" 3 Units Substitute Filter-Regulator w. auto drain, polycarbonate bowls Filter-Regulator w. manual drain, polycarbonate bowls Filter-Regulator w. auto drain, metal bowls Filter-Regulator w. manual drain, metal bowls Thread form Substitute PTF A ISO G (standard) G Flow characteristics Inlet pressure: 10 bar (145 psi) Port size: 1/4” , 40 µm element Outlet pressure (bar) Air flow (dm3/s) Inlet pressure: 10 bar (145 psi) Port size: 3/8” , 40 µm element Outlet pressure (bar) Air flow (dm3/s) Excelon Plus adheres to the following harmoised standard and technical specifications: Ex h IIC T6 Gb Ex h IIIC T85°C Db ATEX Certification No.: NORGREN 18.0001X 2014/34/EU Equipment and protective systems intended for use in potentially explosive atmospheres. The following harmonised standards and technical specifications have been applied ISO 4414:2010 – Pneumatic fluid power – General rules and safety requirements for systems and their components; ISO 80079-36:2016 – Explosive atmospheres – Part 36: Non-electrical equipment for explosive atmospheres – Basic method and requirements; ISO 80079-37:2016 – Explosive atmospheres Part 37: Non-electrical equipment for explosive atmospheres – Non-electrical type of protection constructional safety ‘’c’’ , control of ignition sources ‘’b’’ , liquid immersion ‘’k’’ . For a copy of the Declaration of Conformity (DoC) please use the link http:/ /cdn.norgren.com/pdf/IM_Excelon_Plus_EN_final.pdf
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltd en 8.105.900.03 Accessories Quikclamp® Page 6 820014-51KIT Quikclamp® with bracket assembled Page 6 820014-52KIT Integrated gauge 10 bar gauge 820073-01KIT Integrated gauge 20 bar gauge 820073-02KIT Integrated gauge 4 bar gauge 820073-03KIT Gauge adaptor kit 1/8 PTF 820100-01KIT Gauge adaptor kit R 1/8 820100-02KIT Pressure sensing block 1/4 PTF Page 6 820016-50KIT Pressure sensing block G1/4 Page 6 820016-51KIT Padlock Padlock 840055-01KIT Lockout device 840055-02KIT Porting block 3/8” PTF 820028-50KIT Porting block G3/8 820028-53KIT Pressure switch interface block (18D pressure switch) G1/4 0523109000000000 Pressure switch 18D (0,5 ... 8bar) *1 0881300 Digital pressure switch 0860810 *1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385 *3) Max. pressure of silencers listed in this data sheet : 10 bar. For pressure higher than 10 bar please contact Norgren Silencer Porous plastic silencer *3) G1/4 M/S2 Porous plastic silencer *3) G1/4 0014600000000000 Sinter bronce silencer *3) 1/4 PTF MS002A Port Adaptors Page 7 1/4 PTF 820015-02KIT 3/8 PTF 820015-03KIT G1/4 820015-08KIT G3/8 820015-09KIT Sinter bronce silencer *3) G1/4 T40C2800
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltden 8.105.900.04 Maintenance/Service Spare parts Auto drain kit with metal Nut - Imperial 6000-61KIT Auto drain kit with metal Nut - Metric 6000-60KIT Filter cartridges 40 micron 820038-51KIT Filter Bowl (Guarded Poly bowl with auto drain 6 mm PIF) 820025-51KIT Filter Bowl (Guarded Poly bowl with manual drain) 820025-50KIT Filter Bowl (Metal with S/Glass & auto drain, 6 mm PIF) 820003-51KIT Filter Bowl (Metal with S/Glass & manual drain) 820003-50KIT
25Ø 30Ø 160 34Ø # 25 1 1 # 25 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltd en 8.105.900.05 Dimensions Shut-off valve and Filter-Regulator Dimensions in mm Projection/First angle # Minimum clearance for bowl removal
1 Main ports 1/4” , 3/8”(ISO G/PTF)
18 A/C
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltden 8.105.900.06 Accessories Quikclamp® with wall bracket Quikclamp® Pressure sensing block Full flow porting block Porting block for 18D pressure switch 18D Pressure switch Dimensions in mm Projection/First angle
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2022 - 9669a) © 2020 Norgren Ltd en 8.105.900.07 51D Pressure switch - digital Dimensions in mm Projection/First angle 18D Porting block and 18D assembled Pipe adaptor
1 Switch OUT 1, green LED
2 Switch OUT 2, red LED
3 Dustproof protector
4 Connector M12 x 1
5 Inlet port
6 Alternative inlet port G1/8 plugged
7 Thread for mounting screw
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/ data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. EN - Englisch