Features
12.7 dB Attenuation Range Integral TTL Driver Operating Temp. -55 ˚C to +85˚C Environmental Screening available Specifications CHARACTERISTIC TYPICAL MIN/MAX Ta = 25˚C Ta = -55 ˚C to +85˚C Frequency 50 - 250 MHz 50 - 250 MHz Insertion Loss (dB) 3 4.2 Max. Attenuation Range (dB) 0.1 - 12.7 0.1 - 12.7 0.1 to 0.8 dB ± (0.05 dB + 2%) Max. Accuracy 0.9 to 6.3 dB ± (0.20 dB + 2%) Max. 6.4 to 12.7 dB ± (0.30 dB + 3%) Max. VSWR 1.25:1 1.5:1 Max. Switching Speed (µsec) 2.5 5 Max. Switching Transients (V) 0.8 1.0 Max. DC Vdc +5 +5 Bias mA 10 15 Max. Note: Care should always be taken to effectively ground the case of each unit Truth Table Control Input Attenuator Setting
7 Line TTL
1 Attenuate
0 Thru
Insertion Loss (dB) Start 50 MHz Stop 250 MHz VSWR 2.0 1.5 1.0 Start 50 MHz Stop 250 MHz RF1 Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd RF2 Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd Gnd TAD5009 Typical Performance Data