1 www.PDUKE.com 2015/6/10 TAD100 SERIES
2 X 3 Inch AC-DC POWER SUPPLIES
- LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
- WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
- ACTIVE POWER FACTOR CORRECTION
- BUILT-IN EMI FILTER
- OUTPUT VOLTAGE ADJUSTABLE
- OPEN FRAME DIMENSIONS 2.00 X 3.00 X 1.16 INCH
- 3000VAC INPUT TO OUTPUT REINFORCED INSULATION
- PROTECTION TYPE CLASS I AND CLASS II
- LOW LEAKAGE CURRENT UNDER 300 µA
- OPERATING ALTITUDE 5000M
- 3 YEAR WARRANTY
- UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
- CE MARKED
- COMPLIANT TO RoHS II & REACH
- WIRELESS NETWORK
- TELECOM/DATACOM
- INDUSTRY CONTROL SYSTEM
- MEASUREMENT EQUIPMENT
- SEMICONDUCTOR EQUIPMENT 3000VAC ISOLATION OCP SCP OVP LOW STANDBY POWER PART NUMBER STRUCTURE T A D 100 U S 12 ƶ Application Package Dimension Output Input Output Output Protection Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC) Industry A: Open type U:Universal S: Single 12: 12V N o suffix: CLASS I Application U: U chassis type 85 ~ 264VAC 15: 15V B: CLASS II E: Enclosed type 24: 24V D: Din rail type 28: 28V 36: 36V 48: 48V
2 www.PDUKE.com 2015/6/10 TECHNICAL SPECIFICATION All specifications are typical at 230VAC input, full load and 25 ഒ otherwise noted Input Range Output Voltage Output Current Natural convection Input Power No Load Efficiency Model Number VAC VDC A W % TAD100US12 TU D100US12 TED100US12 TD D100US12 85 ~ 264 12 8.34 0.3 91 TAD100US15 TU D100US15 TED100US15 TD D100US15 85 ~ 264 15 6.67 0.3 92 TAD100US24 TU D100US24 TED100US24 TD D100US24 85 ~ 264 24 4.17 0.3 92 TAD100US28 TU D100US28 TED100US28 TD D100US28 85 ~ 264 28 3.58 0.3 92 TAD100US36 TU D100US36 TED100US36 TD D100US36 85 ~ 264 36 2.78 0.3 91 TAD100US48 TU D100US48 TED100US48 TD D100US48 85 ~ 264 48 2.09 0.3 91 INPUT SPECIFICATIONS Parameter Conditions Min. Typ. Max. Unit Operating input voltage range AC input DC input 120 264 370 VAC VDC Input frequency AC input 47 63 Hz Input current 115VAC and Full Load 230VAC and Full Load 1.15 0.55 A No load input power 230VAC 0.3 Watts Leakage current 264VAC 300 µA Power Factor 0.95 Start up time 1000 ms Rise time 20 ms Hold up time 115VAC and Full Load 22 ms Input inrush current 230VAC 100 A Input protection Internal fuse T3.15A/250VAC
3 www.PDUKE.com 2015/6/10 OUTPUT SPECIFICATIONS Parameter Conditions Min. Typ. Max. Unit Output power 100 Watts Initial set voltage accuracy 230VAC and Full Load -1.0 +1.0 % Line regulation Low Line to High Line at Full Load -0.2 +0.2 % Load regulation No Load to Full Load 10% Load to 90% Load -0.5 -0.4 +0.5 +0.4 % Voltage adjustability -10 +10 % Minimum load 0 % Ripple and noise Measured by 20MHz bandwidth With a 10µF/25V 1206 X7R MLCC With a 10µF/25V 1206 X7R MLCC With a 1µF/50V 1206 X7R MLCC With a 1µF/50V 1206 X7R MLCC With a 1µF/50V 1206 X7R MLCC With a 0.1µF/100V 1206 X7R MLCC 12Vout 15Vout 24Vout 28Vout 36Vout 48Vout 120 150 160 180 190 340 mVp-p Temperature coefficient -0.02 +0.02 %/ ഒ Transient response Load step form 50 ~ 75% change at 2.5A/ µs Peak deviation Recovery time 500 % Vout µs Over voltage protection % of Vout(nom); Latch mode 115 135 % Over load protection % of Iout rated; Hiccup mode 115 150 % Short circuit protection Continuous, automatics recovery GENERAL SPECIFICATIONS Parameter Conditions Min. Typ. Max. Unit Isolation voltage 1 minute (Reinforced insulation) Input to Output Input (Output) to F.G. 3000 1500 VAC Isolation resistance 500VDC 0.1 G Ω Switching frequency 60 kHz Safety approvals UL60950-1 EN60950-1 IEC60950-1 Weight TAD TUD TED TDD 156g (5.50oz) 194g (6.84oz) 210g (7.41oz) 232g (8.18oz) MTBF MIL-HDBK-217F Ta=25 ഒ, Full load 7.903 x 10 5 hrs ENVIRONMENTAL SPECIFICATIONS Parameter Conditions Min. Typ. Max. Unit Operating ambient temperature Natural convection and Full load (with derating) -40 ഒ start up : 80% Load,max. @ Vin > 100VAC -40 ഒ start up : 100% Load,max. @ Vin > 200VAC -40 +85 ഒ Storage temperature range -40 +85 ഒ Operating altitude 5000 m Thermal shock MIL-STD-810F Shock IEC68-2-27 Vibration IEC68-2-6 Relative humidity Non-condensing 5% to 95% RH
4 www.PDUKE.com 2015/6/10 EMC SPECIFICATIONS Parameter Conditions Level EMI EN55011, EN55022 and FCC Part 15 Conducted Radiated Class B Class A Harmonic currents EN61000-3-2 Full Load Class A and D Voltage flicker EN61000-3-3 ESD EN61000-4-2 Air ± 8kV and Contact ± 6kV Perf. Criteria A Radiated immunity EN61000-4-3 20 V/m Perf. Criteria A Fast transient EN61000-4-4 ± 2kV Perf. Criteria A Surge EN61000-4-5 DM ± 1kV and CM ± 2kV Perf. Criteria A Conducted immunity EN61000-4-6 20 Vr.m.s Perf. Criteria A Power frequency magnetic field EN61000-4-8 10 A/m Perf. Criteria A Dip and interruptions EN61000-4-11 and EN55024 CHARACTERISTIC CURVE Derating Curve vs. Ambient Temperature TED100 & TDD100 Derating Curve vs. Ambient Temperature TAD100 & TUD100 Derating Curve vs. Input Voltage TƶD100 Efficiency vs. Output Load TƶD100US24 Efficiency vs. Input Voltage TƶD100US24
5 www.PDUKE.com 2015/6/10 MECHANICAL DRAWING TAD Open type TD D Din rail type TED Enclosed type TU D U chassis type 1. All dimensions in inch (mm) CONNECTORS CONNECTIONS CON1 – Input Connector CON2 – Output Connector Pin 1 Line Pin 1,2 -Vout Pin 3 Neutral Pin 3,4 +Vout Mates with JST housing : VHR-3N JST crimp terminals : SVH-21T-P1.1 Mounting holes marked with must be connected to safety earth for CLASS I application Mates with JST housing : VHR-4N JST crimp terminals : SVH-21T-P1.1