Thermal (T- and TA-Line) TA45-2Phttps://www.schurter.com /PG17_18_19 Circuit Breakers Circuit Breaker for Equipment thermal, 2 pole, Push button actuation See below: Approvals and Compliances
Description
- Thermal circuit breaker - 1 or 2 pole thermal overload protection - Positively trip-free release - High configurability - Snap-in or flange mounted - Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2)
Applications
- Power tools - Industrial appliances - Power supplies Weblinks pdf data sheet, html datasheet, General Product Information, Distributor- Stock-Check, Detailed request for product, Product News Technical Data Rated Voltage AC AC 240 VAC Rated Voltage DC 60 VDC Rated current range AC 0.05 - 20 A Conditional short circuit ca- pacity IEC: Inc, PC1, AC 240 V: 1 kA Degree of Protection from front side IP40 acc. to IEC 60529 Dielectric Strength 4 kV Insulation Resistance 500 VDC > 100 MΩ Lifetime mechanical: 50'000 switching cycles ␣ AC: 1 x Ir: 50'000 switching cycles ␣ DC: 1 x Ir: 50'000 switching cycles Overload AC: min. 40 trips @ 6 x Ir ␣ DC: min. 50 trips @ 4 x Ir Allowable Operation Temp. -10 °C to 55 °C Vibration Resistance ± 0.75 mm @ 5 - 60 Hz acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc Shock Resistance 30 G / 18 ms acc. to IEC 60068-2-27, test Ea Tripping Type Thermal Actuation Type Pushbutton Weight 35 - 40 g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree- ments by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: TA45 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40019880 UL Approvals UL UL File Number: E71572 CCC Approvals CCC CCC Certificate Number: 2013010307660082
Thermal (T- and TA-Line)TA45-2P https://www.schurter.com /PG17_18_19 Circuit Breakers Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60934 Circuit-breakers for equipment (CBE) Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to CSA C22.2 No. 235 Supplementary Protectors Designed according to GB 17701 Circuit-breaker for equipment Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimension [mm] Snap-in type and quick connect terminal 10.8 10.6 21.5 8.45.3 26.7 23.7 44.1 aP1 3 5 18.5 LINE A) Quick connect terminal, IEC 61210, A6.3-0.8 mm Snap-in type and screw clamp terminal aP1 3 5 LINE 10.8 26.910.8 B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm Flange type and quick connect terminal 10.6 8.45.3 26.7 23.7 44.1 aP1 3 5 LINE 10.8 21.5 43.3 39.3 A) Quick connect terminal, IEC 61210, A6.3-0.8 mm Flange type and screw clamp terminal aP1 3 5 LINE 10.8 10.8 32.2 B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm
Thermal (T- and TA-Line) TA45-2Phttps://www.schurter.com /PG17_18_19 Circuit Breakers Cut-out and pin-out Cut-out snap-in type b a (1.0 – 5.0) a b 1.0 44,5...45,0 1.5 44,5...45,0 2.0 44,7...45,2 2.5 44,7...45,2 3.0 44,8...45,3 4.0 44,9...45,4 5.0 45,0...45,5 21.7 +0.2 –0.0 1) Assemble 2) edge must be sharp Cut-out flange type / Installation from rear 4.2 50.5 +0.2 25.2 +0.2 –0.0 –0.0 Cut-out flange type/ Installation from rear with AZZ05 cover 4.2 27.5 +0.3 –0.0 52.5 +0.3 –0.0 Pin-out b a c U-Relais Diagrams 1 pole thermal overload protection P2 P1 1 pole thermal overload protection, Shunt terminal P2 P1 6 5 2 pole thermal overload protection 4 3 P2 P1 2 pole thermal overload protection, Shunt terminal P2 P1 4 3
Thermal (T- and TA-Line)TA45-2P https://www.schurter.com /PG17_18_19 Circuit Breakers Time-Current-CurvesTime in Seconds Type TA45 Rated current In <3 A 1 pole protected 2 pole protected Ambient temp. +23ºC 10'000 2\000 1\000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 10854321,32 Multiple of Rated Current In Reference Temperature +23° Time in Seconds 0,5 0,3 0,2 0,1 10'000 2\000 1\000 500 200 100 [ sec ][ min ] 1,05 10854321,32 Type TA45 Rated current 3 A > In <18 A 1 pole protected 2 pole protected Ambient temp. +23ºC Multiple of Rated Current In Reference Temperature +23° Time in Seconds 0,5 0,3 0,2 0,1 10'000 2\000 1\000 500 200 100 [ sec ][ min ] 1,05 10854321,32 Type TA45 Rated current In > 18 A 1 pole protected 2 pole protected Ambient temp. +23ºC Multiple of Rated Current In Reference Temperature +23°
Thermal (T- and TA-Line) TA45-2Phttps://www.schurter.com /PG17_18_19 Circuit Breakers Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated cur- rent for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient Temperature [°C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: Rated current = 5 A, Environmental temperature = 40 °C, --> Correction factor = 1.08, Resulting current = 5.5 A --> Fount to next higher rated current: 6 A Config. Code The characters are placeholders for the correspondingly keys of selections from the key tables. TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function Basic function Configuration key 2-pole, push button, 1pole overload protection, quick connect terminal, snap-in type, push button gasket IP40 ABL 2-pole, push button, 1pole overload protection, shunt terminal, quick con- nect terminal, snap-in type, push button gasket IP40 ABM 2-pole, push button, 2pole overload protection, quick connect terminal, snap-in type, push button gasket IP40 ABN 2-pole, push button, 2p overload protection, shunt terminal, quick connect terminal, snap-in type, push button gasket IP40 ABP 2-pole, push button, 1pole overload protection, quick connect terminal, snap-in type, push button gasket IP65 ABU 2-pole, push button, 1pole overload protection, shunt terminal, quick con- nect terminal, snap-in type, push button gasket IP65 ABV 2-pole, push button, 2pole overload protection, quick connect terminal, snap-in type, push button gasket IP65 ABW 2-pole, push button, 2p overload protection, shunt terminal, quick connect terminal, snap-in type, push button gasket IP65 ABX 2-pole, push button, 1pole overload protection, screw connection, snap-in type, push button gasket IP40 AEL 2-pole, push button, 1p overload protection, shunt terminal, screw connec- tion, snap-in type, push button gasket IP40 AEM 2-pole, push button, 2pole overload protection, screw connection, snap-in type, push button gasket IP40 AEN 2-pole, push button, 2p overload protection, shunt terminal, screw connec- tion, snap-in type, push button gasket IP40 AEP 2-pole, push button, 1pole overload protection, screw connection, snap-in type, push button gasket IP65 AEU 2-pole, push button, 1p overload protection, shunt terminal, screw connec- tion, snap-in type, push button gasket IP65 AEV 2-pole, push button, 2pole overload protection, screw connection, snap-in type, push button gasket IP65 AEW 2-pole, push button, 2p overload protection, shunt terminal, screw connec- tion, snap-in type, push button gasket IP65 AEX 2-pole, push button, 1pole overload protection, quick connect terminal, flange type, push button gasket IP40 AHL 2-pole, push button, 1pole overload protection, shunt terminal, quick con- nect terminal, flange type, push button gasket IP40 AHM 2-pole, push button, 2pole overload protection, quick connect terminal, flange type, push button gasket IP40 AHN 2-pole, push button, 2p overload protection, shunt terminal, quick connect terminal, flange type, push button gasket IP40 AHP 2-pole, push button, 1pole overload protection, quick connect terminal, flange type, push button gasket IP65 AHU Basic function Configuration key 2-pole, push button, 1pole overload protection, shunt terminal, quick con- nect terminal, flange type, push button gasket IP65 AHV 2-pole, push button, 2pole overload protection, quick connect terminal, flange type, push button gasket IP65 AHW 2-pole, push button, 2p overload protection, shunt terminal, quick connect terminal, flange type, push button gasket IP65 AHX 2-pole, push button, 1pole overload protection, screw connection, flange type, push button gasket IP40 AJL 2-pole, push button, 1p overload protection, shunt terminal, screw connec- tion, flange type, push button gasket IP40 AJM 2-pole, push button, 2pole overload protection, screw connection, flange type, push button gasket IP40 AJN 2-pole, push button, 2p overload protection, shunt terminal, screw connec- tion, flange type, push button gasket IP40 AJP 2-pole, push button, 1pole overload protection, screw connection, flange type, push button gasket IP65 AJU 2-pole, push button, 1p overload protection, shunt terminal, screw connec- tion, flange type, push button gasket IP65 AJV 2-pole, push button, 2pole overload protection, screw connection, flange type, push button gasket IP65 AJW 2-pole, push button, 2p overload protection, shunt terminal, screw connec- tion, flange type, push button gasket IP65 AJX TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour Actuator colour Configuration key Front Black: Green/Red T Front Yellow: Green/Red U Front Grey: Green/Red V TA45 Legend Configuration key embossed I F white printed ON OFF H
Thermal (T- and TA-Line)TA45-2P https://www.schurter.com /PG17_18_19 Circuit Breakers Legend Configuration key black printed ON OFF K white printed I L black printed I M white printed I0 P black printed I0 R white printed OFF ON I S black printed OFF ON I T TA45|-|AK2|W|F| 120 |A2|-|AZM11| = Rated current Rated current Configuration key
0.05 A Z05
0.1 A J01
0.2 A J02
0.3 A J03
0.4 A J04
0.5 A J05
0.6 A J06
0.7 A J07
0.8 A J08
0.9 A J09
1.0 A J10
1.1 A J11
1.2 A J12
1.3 A J13
1.4 A J14
1.5 A J15
1.6 A J16
1.7 A J17
1.8 A J18
1.9 A J19
2.0 A J20
Other rated currents on request Rated current Configuration key
2.1 A J21
2.2 A J22
2.3 A J23
2.5 A J25
2.8 A J28
3.0 A 030
3.5 A 035
4.0 A 040
4.5 A 045
5.0 A 050
6.0 A 060
6.5 A 065
7.0 A 070
7.5 A 075
8.0 A 080
9.0 A 090
10.0 A 100
11.0 A 110
12.0 A 120
13.0 A 130
14.0 A 140
15.0 A 150
16.0 A 160
17.0 A 170
18.0 A 180
19.0 A 190
20.0 A 200
Other rated currents on request TA45 |-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch Release / lock-out latch Configuration key whithout release / lock-out latch C0 TA45 Factory mounted accessories Configuration key Without cover For subsequent fitting accessories see: https://www.schurter.com/pdf/english/typ_TA45-ACC.pdf Variants Thermal overload pro tection Addition connection type Mounting IP Protection Class Front Side Actuator colour Legend Rated current Accessories Config. Code Order Number2-pole Quick connect terminal Flange type IP65 Front Black: Green/Red white printed 20.0 A Without cover TA45-AHWTL200C0 4430.3513 2-pole Quick connect terminal Snap-in type IP40 Front Black: Green/Red embossed 12.0 A Without cover TA45-ABNTF120C0 4430.3516
Thermal (T- and TA-Line) TA45-2Phttps://www.schurter.com /PG17_18_19 Circuit Breakers Thermal overload pro- tection Addition connection type Mounting IP Protection Class Front Side Actuator colour Legend Rated current Accessories Config. Code Order Number 1-pole Quick connect terminal Snap-in type IP65 Front Black: Green/Red black printed 10.0 A Without cover TA45-ABUTM100C0 4430.3608 Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTERPackaging Unit 1 Pcs Accessories The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 18.07.2019