Features

/square6 Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. /square6 Suitable for automobile, machine, electronic equipment, air conditioner and household appliance applications. /square6 PC board mounting.

Ordering Information

NT90 R H A S DC12V C B 0 . 9 1 2 3 4 5 6 7 8 9

1 Part number:NT90T、NT90T2

2 Terminal: R: without Pin 6 ;NIL: With Pin 6

3 Load:H:30A;N:40A

4 Contact arrangement:1A:1A;1B:1B;1C:1C

5 Enclosure:S: Sealed type;D: Dust cover;

E : C o v e r e d ;O: Open type

6 Coil rated Voltage(V):AC:12,24,110,120,220

7 Contact material:C: Ag/square2CdO;S: Ag/square2SnO2

8 Resist heat class:B:130℃ F:155 ℃

9 Coil power consumption:0.6:0.6W;0.9:0.9W N I L : 2 V A Contact Data Contact Arrangement 1A/G1c4SPSTNO/G1c5/G1021B(SPSTNC)/G1021C(SPDT(B-M)) Contact Material Ag /square2CdO Ag /square2SnO2 Ag /square2SnO2/square2In2O3 Contact Rating (resistive) NO : 30A/240VAC,14VDC; NC:20A/240VAC ;30A/14VDC NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W) Motor load:2HP 250VAC ;1.5HP 250V Lamp load:TV-5 Max. Switching Power 1100W 7200VA Max. Switching Voltage 110VDC 250VAC Max. Switching Current:40A Contact Resistance or Voltage drop /c476830m/G2ee Item 3.12 of IEC255-7 life Mechanical 10 7 Item 3.31 of IEC255-7 Coil Parameter AC Coil Parameter RATED VOLTAGE VACDASH NUMBERS RATED Max COIL RESISTANCE /G2ee±10% PICK UP VOLTAGE VAC(max) (75%of rated voltage) RELEASE VOLTAGE VAC(min) (30%of rated voltage) COIL POWER Operate Time ms Release Time ms 012AC 12 15.6 27 9.0 3.6 024AC 24 31.2 120 18.0 7.2 110AC 110 143 2360 82.5 33.0 120AC 120 156 3040 90.0 36.0 220AC 220 286 13490 165.0 66.0 2VA _ _ CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 103 E160644 R2033977.05 Patent No. 95213824.7 99218304.9 99312549.2 01311661.4 CH0050401—2000 E9930952E01

/G2ee±10% PICK UP VOLTAGE VDC(max) (75%of rated voltage) RELEASE VOLTAGE VDC(min) (10%of rated voltage) COIL POWER W Operate Time ms Release Time ms 003-900 3 3.9 10 2.25 0.3 005-900 5 6.5 28 3.75 0.5 006-900 6 7.8 40 4.50 0.6 009-900 9 11.7 90 6.75 0.9 012-900 12 15.6 160 9.00 1.2 015-900 15 19.5 250 10.25 1.5 018-900 18 23.4 360 13.50 1.8 024-900 24 31.2 640 18.00 2.4 048-900 48 62.4 2560 36.00 4.8 110-900 110 143 13445 82.50 11.0 0.9 /G13c15 /G13c10 003-600 3 3.9 15 2.25 0.3 005-600 5 6.5 42 3.75 0.5 006-600 6 7.8 60 4.50 0.6 009-600 9 11.7 135 6.75 0.9 012-600 12 15.6 240 9.00 1.2 015-600 15 19.5 375 10.25 1.5 018-600 18 23.4 540 13.50 1.8 024-600 24 31.2 960 18.00 2.4 048-600 48 62.4 3840 36.00 4.8 110-600 110 143 20167 82.50 11.0 0.6 /G13c15 /G13c10 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. Qualification inspection: Perform the qualification test as specified in the table /G1b2 of IEC255-19-1 and minimum sample size 24. Operation condition Insulation Resistance 1000M/G2ee/G2ee/G2ee/G2ee min (at 500VDC) Item 7 of IEC255-5 Dielectric Strength Between contacts Between contact and coil 50Hz 1500V 50Hz 2500V 4000V /G1c4without Pin 6/G1c5 Item 6 of IEC255-5 Item 6 of IEC255-5 Shock resistance 200m/s 2 11ms IEC68-2-27 Test Ea Vibration resistance 10~55Hz double amplitude 1.5mm IEC68-2-6 Test Fc Terminals strength 10N IEC68-2-21 Test Ua1 Solderability 235/G146/G1202/G146 3 /G1200.5s IEC68-2-20 Test Ta method 1 Ambient Temperature -55~100/G146 -55~125 /G146 Relative Humidity 85% (at 40/G146) IEC68-2-3 Test Ca Mass 27g/G1c4 Open type /G1c5 30g NT90 (T90)

Safety approval UL TüV CCEE Load No:40A/250VAC 30A/277VAC Nc:30A/250VAC 20A/277VAC 2HP 250VAC TV-5 11/2HP 250VAC Insulation/G1d6B-class F - c l a s s No 40A/240VAC 14VDC Nc 30A/240VAC 14VDC Insulation/G1d6B-class F - c l a s s No 30A/240VAC Nc 20A/240VAC Dimensions (Unit: mm) Reference Data N O T E S 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. Dimensions Mounting (Bottom views) Wiring diagram(Bottom views) m m i n c h 0.5 0.020 0.7 0.027 0.8 0.031 1.1 0.043 1.2 0.047 1.5 0.059 2.1 0.083 2.4 0.094 2.54 0.100 3.3 0.130 3.7 0.146 3.8 0.150 5.3 0.209 7.7 0.303 8.9 0.350 12.5 0.492 14 0.551 15.4 0.606 17 0.669 17.8 0.701 18.4 0.724 20 0.787 22.4 0.882 24.2 0.953 27.6 1.087 30.5 1.201 32.5 1.279 105