CWR09CB105KMA KEMET | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

DIMENSIONS – MILLIMETERS (INCHES) KEMET Size Code L Length ± .38 (.015) W Width ± 0.38 (.015) H Height ± 0.38 (.015) P +0.25 (.010) - 0.13 (.005) Minimum OUTLINE DRAWING F-9083B 01/07 T409/T419/T429 Series - MIL-PRF-55365/4 & /11 Tantalum Surface Mount Capacitor

FEATURES

Established Reliability Military Version of T497 Series High Grade COTS Capacitance Values and Voltages as shown in following part number table. Qualified to MIL-PRF-55365/4 & 11, Style CWR09, CWR19, CWR29 Termination Options: B (Gold Plated), C (Hot Solder Dipped), H (Solder Plated), K (Solder Fused 100% Surge Current Test available for all sizes Precision-molded, Laser-marked Case Operating Temperature -55°C to +125°C Offered in Nine Case Sizes (A - X) Weibull Failure Rate Codes, B, C, D# 50V Not Qualified Tape & Reeled per EIA 481-1 COMPONENT MARKING 105 20K 620 Polarity Indicator (+) (Solid Stripe) Picofarad Code Rated Voltage Print Week Code 1st Digit = Year 2nd & 3rd Digits = Week “620” = 20th Week of 2006 J High Capacitance Ultra-low ESR Device COMPONENT WEIGHT Case Size Avg. Weight (gm) Case Size Avg. Weight (gm) A 0.016 F 0.153 B 0.024 G 0.235 C 0.034 H 0.365 D 0.050 X 0.406 E 0.072

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com KEMET ORDERING INFORMATION Surge Designator

4250 Surge = +25°C after Weibull

4251 Surge = -55°C +85°C after Weibull

4252 Surge = -55°C +85°C before Weibull

Note: For order entry purposes the last 4-digits of the part number will be entered in the KEMET Customer Specification (C-Spec)Field. Termination Finish B = Gold plated C = Hot solder dipped H = Solder plated K = Solder fused Capacitance Tolerances Tantalum Series T409 MIL-PRF-55365/4 T419 MIL-PRF-55365/11 T429 MIL-PRF-55365/11 Case Size A, B, C, D, E, F, G, H, X Capacitance Picofarad Code First two digits represent significant figures. Third digit specifies number of zeros to follow. T 409 B 105 K 020 C H 4250 Voltage As shown Capacitance Tolerance Voltage C = 4V J = 20V D = 6V K = 25V F = 10V M = 35V H = 15V N = 50V Termination Finish Code B = Gold plated C = Hot solder dipped H = Solder plated K = Solder fused Capacitance Picofarad Code First two digits represent significant figures. Third digit specifies number of zeros to follow. Style CWR19, CWR29 CWR19 K H 225 K C D A Surge Current Option A = +25°C after Weibull B = -55°C +85°C after Weibull C = -55°C +85°C before Weibull Z = None MIL-PRF-55365 (CWR19/29) ORDERING INFORMATION Case Code A,B,C,D,E,F,G,H,X Capacitance Tolerance Voltage C = 4V J = 20V D = 6V K = 25V F = 10V M = 35V H = 15V N = 50V Reliability Level * Exponential Weibull M = (1.0%/1000 hrs.) A = Non-ER * Inactive for new design. Termination Finish Code B = Gold plated C = Hot solder dipped H = Solder plated K = Solder fused Capacitance Picofarad Code First two digits represent significant figures. Third digit specifies number of zeros to follow. Style CWR09 CWR09 J H 105 K C A Surge Current Option A = +25°C after Weibull B = -55°C +85°C after Weibull C = -55°C +85°C before Weibull MIL-PRF-55365 (CWR09) ORDERING INFORMATION Reliability Level * Exponential Weibull M = (1.0%/1000 hrs.) A = Non-ER * Inactive for new design. Reliability Level *Exponential Weibull M = (1.0%/1000 hrs.) A = Non-ER * Inactive for new design.

T409 (CWR09) Ratings & Part Number Reference Capaci- tance μF Case Size KEMET Part Number Mil-C-55365/4F Part Number DC Leakage μA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max 4 Volt Rating at +85°C (2.7 Volt Rating at +125°C)

6 Volt Rating at +85°C (4 Volt Rating at +125°C)

10 Volt Rating at +85°C (7 Volt Rating at +125°C)

15 Volt Rating at +85°C (10 Volt Rating at +125°C)

20 Volt Rating at +85°C (13 Volt Rating at +125°C)

25 Volt Rating at +85°C (17 Volt Rating at +125°C)

35 Volt Rating at +85°C (23 Volt Rating at +125°C)

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll Surge Current Option.

T409 (CWR09) Ratings & Part Number Reference © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Capaci- tance μF Case Size KEMET Part Number Mil-C-55365/4F Part Number DC Leakage μμA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max

50 Volt Rating at +85 C (33 Volt Rating at + 125 C)

Pitch - mm ± 0.1 Reel Quantity Part Sprocket 180mm (7” diameter) 330mm (13” diameter) A 1005 8 4 4 2500 9500 B 1505 12 4 4 2500 9500 C 2005 12 4 4 2500 9500 D 1510 12 4 4 2500 9500 E 2010 12 4 4 2500 9500 F 2214 12 8 4 1000 3500 G 2711 12 8 4 500 2500 H 2915 12 8 4 500 2500 X 2824 12 8 4 500 2500 Packaging Information (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. Note: D# - 50 Volt Components not Qualified to D Product Level. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll Surge Current Option.

  • No c-spec required for 7” reel packaging. C-7280 required for 13” reel packaging
  • Standard reel packaging is not mandatory
  • Bulk packaging also available using C-7610

μF Case Size KEMET Part Number Mil-C-55365/11A Part Number DC Leakage μμA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max 4 Volt Rating at +85°C (2.7 Volt Rating at +125°C) T419 (CWR19) Ratings & Part Number Reference © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll Surge Current Option.

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Capaci- tance μF Case Size KEMET Part Number Mil-C-55365/11A Part Number DC Leakage μμA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max T419 (CWR19) Ratings & Part Number Reference (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll Surge Current Option.

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Capaci- tance μF Case Size KEMET Part Number Mil-C-55365/11A Part Number DC Leakage μμA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max 4 Volt Rating at +85°C (2.7 Volt Rating at +125°C) T429 (CWR29) Ratings & Part Number Reference (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll Surge Current Option.

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Capaci- tance μF Case Size KEMET Part Number Mil-C-55365/11A Part Number DC Leakage μμA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max 10 Volt Rating at +85°C (7 Volt Rating at +125°C) cont. T429 (CWR29) Ratings & Part Number Reference (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll Surge Current Option.

© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Capaci- tance μF Case Size KEMET Part Number Mil-C-55365/11A Part Number DC Leakage μμA @ 25ºC Max DF % @ +25ºC 120 Hz Max ESR ΩΩ @ +25°C 100 kHz Max 20 Volt Rating at +85°C (13 Volt Rating at +125°C) cont. T429 (CWR29) Ratings & Part Number Reference (1) To complete KEMET/CWR part number, insert K = ±10%; M = ±20% and J = ±5% Capacitance tolerance. Note: D# - 50 Volt Components not Qualified to D Product Level. (3) To complete KEMET part number, insert B = Gold plated; C = Hot solder dipped; H = Solder plated or K = Solder Fused Terminat ion Finish. (4) To complete KEMET part number, insert 4250 = +25°C after Weibull; 4251 = -55° + 85°C after Weibull; or 4252 = -55, & +85°C b efore Weibull Surge Current Option. (5) To complete CWR part number, insert A = +25°C after Weibull; B = -55° + 85°C after Weibull; or C = -55, & +85°C before Weibu ll SurgeCurrent Option.

Size Code Pad Dimensions (mm) KEMET EIA Z G X Y (Ref) C (ref) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com Land Pattern Dimensions for Reflow Solder