T30AD9 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

No revision without agency approval.

  • Designed for use with approved amplifiers and intrinsically safe barriers in explosive environments
  • NAMUR compliant sensor featuring EZ-BEAM ® technology; the specially designed optics and electronics provide reliable sensing without the need for adjustments
  • "T" style plastic housing with 30 mm threaded lens
  • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments; Banner tested to IP69K
  • Innovative dual-indicator system takes the guesswork out of sensor performance monitoring
  • Advanced diagnostics to warn of marginal sensing conditions or output overload
  • 5 to 30 V dc; constant current output; ≤ 1.2 mA in the "dark" condition and ≥ 2.1 mA in the "light" condition WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Model Connection Far-Limit Cutoff LED Output Type T30AD9FF150 2 m (6.5 ft) unterminated PVC-jacketed cable 150 mm (5.9 in) Infrared, 880 nm Constant current ≤ 1.2 mA dark ≥ 2.1 mA lightT30AD9FF150Q Integral 4-pin M12/Euro-style male quick disconnect (QD) Overview T30AD9FF150 NAMUR Series Sensor is a self-contained fixed-field sensors are small, powerful, infrared diffuse mode sensors with far-limit cutoff (a type of background suppression). The sensor is designed for use with certified intrinsically safe switching amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits. The T30AD9FF150 NAMUR Series Sensor is designed in accordance with DIN 19234 (IEC/EN 60947-5-6) for operation via two-wire connection to an Approved Apparatus controlled by the variable internal resistance of the sensor. Their high excess gain and fixed-field technology allow detection of objects of low reflectivity, while ignoring background surfaces. The cutoff distance is fixed. Backgrounds and background objects must always be placed beyond the cutoff distance. Models are available with either a 2 m (6.5 ft) long attached PVC-covered cable or a 4-pin M12/Euro-style quick disconnect (QD) connector. Quick disconnect models (with "Q" in the model number suffix) use MQD9-4.. mating cable (either straight or right angle connector; see Accessories on page 6). Contact Banner Engineering for availability of sensor models with 9 m (30 ft) long attached cable. Fixed-Field Sensing – Theory of Operation The T30AD9FF150 NAMUR Series Sensor compares the reflections of its emitted light beam (E) from an object back to the sensor's two differently aimed detectors, R1 and R2. See Figure 1 on page 2. If the near detector's (R1) light signal is stronger than the far detector's (R2) light signal (see object A in the Figure below, closer than the cutoff distance), the sensor responds to the object. If the far detector's (R2) light signal is stronger than the near detector's (R1) light signal (see object B in the Figure below, beyond the cutoff distance), the sensor ignores the object. The cutoff distance for the T30AD9 is fixed at 150 mm (5.9 in). Objects lying beyond the cutoff distance are usually ignored, even if they are highly reflective. However, under certain conditions, it is possible to falsely detect a background object (see Background Reflectivity and Placement on page 3). T30AD9 NAMUR Series Fixed-Field Sensor Original Document 41685 Rev. F

12 March 2018

  • Approved Apparatus entity parameters must meet the following requirements: ◦ o Voc or Vt ≤ Vmax ◦ o Ca ≥ Ci + Ccable ◦ o Isc or It ≤ Imax ◦ o La ≥ Li + Lcable
  • Sensor Entity Parameters: ◦ Vmax (Ui) ≤ 30 V dc ◦ Imax (li) ≤ 35 mA ◦ Ci = 0 μF ◦ Li = 0 mH
  • Cable Entity Parameters (if unknown): ◦ Ccable = 60 pF/ft ◦ Lcable = 0.2 µH/ft
  • The ambient operating temperature range of the Sensors is –40 °C to +70 °C (–40 °F to +158 °F).
  • For intrinsically safe installations, sensors must be used with certified intrinsically safe switching amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits that limit supply voltage and current in the event of failures.
  • Maximum non-hazardous area voltage that the Approved Apparatus (intrinsically safe circuit) is connected to must not exceed 250V.
  • Intrinsic safety ground, if required for the Associated Apparatus, shall be less than 1 ohm.
  • Maximum connector torque: 6 ft-lbs. Wiring Connections The T30AD9FF150 NAMUR Series Sensor is intrinsically safe ONLY when used with certified intrinsically safe switching amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits. Banner does not manufacture such devices; however, our applications engineers can refer you to suppliers of certified devices that will interface with Banner sensors. The user is responsible for proper installation and maintenance of this equipment, and must conform with the certification requirements relating to barriers and to maximum allowable capacitance and inductance of the field wiring. If in doubt about these requirements, our applications engineers can refer you to the appropriate authority. Cabled Models Quick-Disconnect Models NAMUR Sensor Hazardous Area ≤ 30 V dcPower Output Sensor Input Non-hazardous Area Approved Apparatus br bu NAMUR Sensor Hazardous Area ≤ 30 V dcPower Output Sensor Input Non-hazardous Area Approved Apparatus br bu Configuration Instructions Sensing Reliability For highest sensitivity, position the target for sensing at or near the point of maximum excess gain. Maximum excess gain for all models occurs at a lens-to-object distance of about 40 mm (1.5 in). Sensing at or near this distance makes the maximum use of each sensor’s available sensing power. The background must be placed beyond the cutoff distance. Note that the reflectivity of the background surface also may affect the cutoff distance. Following these guidelines improves sensing reliability. Background Reflectivity and Placement Avoid mirror-like backgrounds that produce specular reflections. A false sensor response occurs if a background surface reflects the sensor's light more to the near detector (R1) than to the far detector (R2). The result is a false ON condition (Figure 3 on page 4). Correct this problem by using a diffusely reflective (matte) background, or angling either the sensor or the background (in any plane) so the background does not reflect light back to the sensor (Figure 4 on page 4). Position the background as far beyond the cutoff distance as possible. T30AD9 NAMUR Series Fixed-Field Sensor P/N 41685 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 3

Supply Voltage and Current 5 to 30 V dc (provided by the amplifier to which the sensor is connected) Output Constant current output; ≤1.2 mA in the dark condition and ≥2.1 mA in the light condition Output Response Time 10 ms on/off (does not include amplifier response) Sensing Beam Infrared (880 nm) Cutoff Distance 150 mm (5.9 in), referenced to a 90% reflectance white test card. See excess gain curve. Indicators Red indicator LED on rear panel turns on when the sensor sees a light condition. Operating Conditions Temperature: –40 °C to +70 °C (–40 °F to +158 °F) Application Note Special Conditions for Safe Use: Parts of the enclosure are non-conducting and may generate an ignition-capable level of ESD. Cleaning of the equipment must be done only with a damp cloth. Construction Yellow PBT enclosure, PBT rear cover. Acrylic lens. M30xl,5 threaded lens housing with two mounting nuts supplied. Banner tested to NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 6P, 12, and 13. IEC IP67. Connections 2 m (6.5 ft) attached PVC covered cable or 4-pin M12/Euro-style quick- disconnect (QD) fitting, depending on model. QD cable must be purchased separately. Vibration and Mechanical Shock Meets Mil. Std. 202F requirements. Method 201A (Vibration: frequency 10 to 60 Hz max., double amplitude 0.06-inch, maximum acceleration 10G). Method 213B conditions H & I (Shock: 75G with unit operating; 100G for non-operation). Certifications 1725 IEC IECEx FMG 14.0029XATEX FM12ATEX0094XFM CoC 0003046293 (US)FM CoC 0003046293C (CAN) Design Standards ATEX (European) EN 60079-0, EN 60079-11 and EN 60079-26 United States FM Class 3600, 3610, and 3810; ANSI/ISA 61010-1 (82.02.01), 60079-0 and 60079-11 IECEx IEC 60079-0, IEC 60079-11 Approvals T30AD9FF150, T30AD9FF150Q ATEX (European) II 1 G Ex ia IIC T6 Ga Ta = –40°C to 70°C - 41685; Entity Entity Parameters: U i = 30 V dc, I i = 35 mA, C i = 0 μF, L i = 0 mH. Canadian IS / I,II,III / 1 / ABCDEFG / T6 Ta = –40°C to 70°C - 41685; Entity I / 0 / Ex ia / IIC / T6 Ta = –40°C to 70° C - 41685; Entity Entity Parameters: V Max = 30 V dc, I Max = 35 mA, C i = 0 μF, L i = 0 mH United States IS / I,II,III / 1 / ABCDEFG / T6 Ta = –40°C to 70°C - 41685; Entity I / 0 / AEx ia / IIC / T6 Ta = –40°C to 70°C - 41685; Entity Entity Parameters: V Max = 30 V dc, I Max = 35 mA, C i = 0 μF, L i = 0 mH IECEx Ex ia IIC T6 Ta= –40 °C to +70 °C - 41685; Entity Entity Parameters: U i = 30 V dc, I i = 35 mA, C i = 0 μF, L i = 0 mH. FM 12ATEX0094X Ex ia IIC T6 Ga Ta = -40°C to +70°C IECEx FMG 14.0029X Ex ia IIC T6 T30AD9 NAMUR Series Fixed-Field Sensor P/N 41685 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 5

1 mm(0.04") 100 EXCESS GAIN DISTANCE 1000 T30 NAMUR Fixed-FieldPerformance is based on the use of a 90% reflectance white test card. Using 18% gray test card: cutoff distance is 95% of the value shown. Using 6% black test card: cutoff distance is 90% of the value shown. Dimensions Cabled Models QD Models 11.5 mm(0.45") 66.5 mm(2.62") Red LEDAlignment Indicator Jam Nut(Supplied) M30 x 1.5Thread ø 15 mm(0.59") ø 40.0 mm(1.57") 45.0 mm(1.77") 51.5 mm(2.03") Accessories Cordsets 4-Pin Threaded M12/Euro-Style Cordsets (for use with NAMUR sensors) Model Length Style Dimensions Pinout (Female) MQD9-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = Blue MQD9-415 4.57 m (15 ft) MQD9-430 9.14 m (30 ft) T30AD9 NAMUR Series Fixed-Field Sensor 6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 41685 Rev. F

4-Pin Threaded M12/Euro-Style Cordsets (for use with NAMUR sensors) Model Length Style Dimensions Pinout (Female) MQD9-406RA 1.83 m (6 ft) Right-Angle 32 Typ.[1.26"] 30 Typ.[1.18"] ø 14.5 [0.57"] M12 x 1 MQD9-415RA 4.57 m (15 ft) MQD9-430RA 9.14 m (30 ft) Brackets T30 Series sensors may also be mounted in a 30 mm clearance hole up to 15 mm (0.6 in) deep, using the supplied jam nut(s). All measurements are in mm SMB30A

  • Right-angle bracket with curved slot for versatile orientation
  • Clearance for M6 (¼ in) hardware
  • Mounting hole for 30 mm sensor
  • 12-ga. stainless steel

69 A B

C Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5 SMB30SC

  • Swivel bracket with 30 mm mounting hole for sensor
  • Black reinforced thermoplastic polyester
  • Stainless steel mounting and swivel locking hardware included B A Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 Repairs and Translations Obtain assistance with product repairs by contacting your local Banner Engineering Corp distributor or by calling Banner directly at (763) 544-3164. Access literature translated into your native language on the Banner website at www.bannerengineering.com or contact Banner directly at (763) 544-3164. Para reparaciones de productos, por favor contacte a su distribuidor local de Banner Engineering o llame a Banner directamente al (763) 544-3164. Vea la literatura traducida en su idioma en el sitio web Banner en www.bannerengineering.com o comuníquese con Banner directamente al (763) 544-3164. Pour vous aider lors de la réparation de produits, contactez votre distributeur Banner local our appelez directement Banner au (763) 544-3164. La documentation traduite dans votre langue est disponible sur le site internet de Banner www.bannerengineering.com ou contactez directement Banner au (763) 544-3164. Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. T30AD9 NAMUR Series Fixed-Field Sensor © Banner Engineering Corp. All rights reserved