All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks of 4 T2 Pressure Transmitter

FEATURES

Numerous ranges, process connections/electrical terminations, and outputs available (STD.) All stainless steel wetted parts Proven polysilicon film sensor All welded construction NSF-61 Compliant TYPICAL USES Process automation Compressor control Hydraulic systems Engine monitoring Pump control Pneumatics Refrigeration equipment Presses Machine tools Other general industrial applications KEY BENEFITS

  • Broad temperature capability
  • High EMI/RFI immunity ratings
  • High performance ASIC based electronics
  • Superior long-term stability and repeatability PERFORMANCE SPECIFICATIONS Reference Temperature: 72 °F (22 °C) Accuracy Class (BFSL): ±0.25% of span Total Error Band Accuracy (TEB): ±1% of Span: From –20 to 85 ºC (–4 to 185 ºF) ±1.5% of Span: From –40 to –20 ºC (–40 to –4 ºF) ±1.5% of Span: From 85 to 125 ºC (185 to 257 ºF) Includes the combined effects of non-linearity (Ter- minal Point Method), hysteresis, non-repeatability, temperature and zero offset and span setting errors Durability: 50 million cycles Stability: ≤±0.25% span/year at reference conditions Approvals: NSF-61, CE /UKCA, UL (UL 61010-1), (CSA 222 6101-1) UL Recognized component per UL-610101, and CSA 22.2 6101-1, Electrical Equipment for Measurement, Control and Laboratory use ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: Operating: Compensated: –40 °F to 257 °F (–40 °C to 125 °C) –40 °F to 257 °F (–40 °C to 125 °C) –40 °F to 257 °F (–40 °C to 125 °C) Humidity Effects: No performance effects from 0-100% R.H. FUNCTIONAL SPECIFICATIONS Response Time: <1 ms Pressure Ranges: Compound and gauge pressure, 30 to 20,000 psi Shock: 100 gs, 6 ms Vibration: Random vibration (20 g) over temperature range –40 °F to 257 °F (–40 °C to 125 °C). Exceeds typical MIL. (STD.) requirements Position Effect: <±0.01% span, typical Overpressure: ≤750 psi ≥1,000 to ≤4,000 psi >5,000 to ≤7,500 psi ≥10,000 to ≤20,000 psi Proof:

2 X Range

1.2 X Range

Burst:

10 X Range

5 X Range

2.4 X Range

Drop Test: Withstands 1 meter on concrete 3 axis Warm-up Time: <500 msec, typical Pressure Transmitter

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks of 4 T2 Pressure Transmitter ELECTRICAL SPECIFICATIONS Output: Supply Voltage Supply Current 0-5 Vdc (3 Wire) 9 Vdc to 36 Vdc 5 mA 0-10 Vdc (3 Wire) 14 Vdc to 36 Vdc 5 mA 1-5 Vdc, 1-6 & 0.5-4.5 Vdc (3 Wire) 9 Vdc to 36 Vdc 4 mA 0.5-4.5 Vdc, 3 Wire (Ratiometric) 5 Vdc ±0.5 Vdc 3.5 mA 4-20 mA (2 Wire) 9 Vdc to 36 Vdc Insulation Breakdown Voltage: >100 MΩ @ 100 Vdc Circuit Protection: Reverse polarity and mis-wire protected Insulation Resistance: 100 MΩ @ 30 Vdc PHYSICAL SPECIFICATIONS Environmental Rating: Ingress rating NEMA 4X, IP65 LOAD LIMITATIONS 4-20 mA OUTPUT ONLY OPTIONAL FEATURES Calibration Report: 9 pt. Traceable calibration certificate Consult factory for: Throttle plugs and Cleaned for Oxygen services To Determine Min. loop supply voltage: LSVMin=9(V)+[0.022(A)*RL ] Where: LSV= Loop Supply Voltage (Vdc) RL = RS+ RW (ohms) RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) [Measuring Instrument] RW = Wiring Resistance (ohms) 10 40 9 (Min.) 36 (Max.) Loop Supply Voltage (Vdc) [LSV] Power Supply Voltage vs. Loop Resistance (4-20 mA ONLY) Loop Resistance (RL-/uni03A9) 1,400 1,200 1,227 1,000 WETTED MATERIAL Diaphragm 17-4PH Stainless Steel Process Connection 304 Stainless Steel NON-WETTED Housing 20% Glass Reinforced Nylon, Fire retardant to UL94 V1

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks of 4 T2 Pressure Transmitter ORDERING CODE Example: T2 7 M01 42 DN 60# G XTU Model T27 - T2 Series, 1.0% Total Error Band (-20°C/85°C), 1.5% Total Error Band (-40°C/-20°C), (85°C/125°C) T2 7 Pressure Connection Size M01 - 1⁄8 NPT Male M01 M02 - 1/4 NPT Male MEK - 7⁄16 20 SAE #4 Male, not UL reconginzed over 10,000 psi range MEV - 9⁄16-18 SAE #6 Male w/Buna-N O-ring, not UL recognized over 10,000 psi range MS2 - 1/4-19 bsp Male, not UL recognized over 10,000 psi range MG2- G 1/4 B Male Output Signal 05 - 0-5 Vdc 10 - 0-10 Vdc 15 - 1-5 Vdc 16 - 1-6 Vdc 42 - 4-20 mA 42 RM - 0.5-4.5 Vdc Ratiometric to 5 Vdc supply Electrical Termination EN 175301-803, Form A (DIN 43650 Form A - Mates to Hirschmann ® GDM 3009 or similar) DN - No mating connector DN D0 - W/mating connector, no cable D2 - W/mating connector, 3 feet of shielded cable Electrical Connection M12 (4-Pin) - Mates to Hirschman 933-172-100 or similar EW - No mating connector EO - W/mating connector, no cable E2 - W/mating connector, 3 feet of shielded cable Circular 4 Pin - Mates to Bendix ® PT06A-8-4S-SR or similar B4 - No mating connector H1 - W/mating connector, no cable L1 - W/mating connector, 3 feet of shielded cable Pigtail - Shielded cable with PVC jacket and 24 AWG leads F2 - W/3 feet cable length F3 - W/10 feet of cable length P1 - Customer specified length Pressure Range (see range table on page 4) 60# - 60 psi 60# Measurement Type G - Gauge G Option (if including an option(s) must include an “X’’) X__ TU - Throttle Plug TU 6B - Cleaned for oxygen service RH - 9 point Traceable calibration certificate TOTAL ERROR BAND (TEB) Error limits of all points (0-100% of range) Error (% of span) Ambient Temperature (C) -60 -40 -20 0 20 40 60 80 100 120 140 2.0% 1.5% 1.0% 0.5% 0.0% -0.5% -1.0% -1.5% -2.0% Pos Error Limit Neg Error Limit TOTAL ERROR BAND (TEB)

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks of 4 T2 Pressure Transmitter MATING CONNECTOR LOCATION AND SIZE "L" 0.23 0.32 2.03 [27] 1.06 HEX SHIELDED CABLE ø 1.32 0.75 0.30 1.61 3.450 1.063 2.04 0.23 MATING CONNECTOR LOCATION AND SIZE 1.32 DIN FORM-A ø PVC Jacket, 3´ Length Standard, 24 AWG Leads Mates to Hirschmann GDM 3009 or similar Shielded Cable Din Form-A MATING CONNECTOR LOCATION AND SIZE "L" 0.23 0.32 2.03 [27] 1.06 HEX SHIELDED CABLE ø 1.32 0.75 0.30 1.61 3.450 1.063 2.04 0.23 MATING CONNECTOR LOCATION AND SIZE 1.32 DIN FORM-A ø PVC Jacket, 3´ Length Standard, 24 AWG Leads Mates to Hirschmann GDM 3009 or similar DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings RANGE TABLE Range Code Notes Compound 30 psi/-14.7 psi 30#&vac 45 psi/-14.7 psi 45#&vac 60 psi/-14.7 psi 60#&vac 85 psi/-14.7 psi 85#&vac 100 psi/-14.7 psi 100#&vac 150 psi/-14.7 psi 150#&vac 200 psi/-14.7 psi 200#&vac 300 psi/-14.7 psi 300#&vac 500 psi/-14.7 psi 500#&vac Positive Pressure 30 psi 30# 50 psi 50# 60 psi 60# 100 psi 100# 150 psi 150# 200 psi 200# 250 psi 250# 300 psi 300# 400 psi 400# 500 psi 500# 750 psi 750# 1,000 psi 1000# 1,500 psi 1500# 2,000 psi 2000# 3,000 psi 3000# 5,000 psi 5000# 6,000 psi 6000# 7,500 psi 7500# 10,000 psi 10000# 15,000 psi 15000# Only available with M01, M02, MG2, process connections 20,000 psi 20000# Only available with M01, M02, MG2, process connections bar, kPa, and mPa ranges also available