Technical content

For complete technical information about this product, including dimensions, accessories, and specifications, see http:// www.bannerengineering.com and search for your model number. See also document 121525. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self- checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Models 1 Sensing Mode Range LED Output T183E Opposed 20 m (66 ft) Infrared, 950 nm T18AW3R LO T18RW3R DO T18AW3L Retroreflective with Gain Control 2 m (79 in) 2 LO T18RW3L DO T18AW3LP Polarized Retroreflective Visible Red, 680 nm LO T18RW3LP DO T18AW3D Diffuse with Gain Control 300 mm (12 in) Infrared, 880 nm LO T18RW3D DO T18AW3FF25 Fixed Field 25 mm (1 in) Cutoff LO T18RW3FF25 DO T18AW3FF50 50 mm (2 in) Cutoff LO T18RW3FF50 DO T18AW3FF100 100 mm (4 in) Cutoff LO T18RW3FF100 DO Wiring Cabled Emitters All Other Cabled Models Key 3 20-250 V ac 20-250 V ac Load 1. Brown 2. White 3. Blue 4. Black 1 Standard 2 m (6.5 ft) cable models are listed.

  • To order the 9 m (30 ft) cable models, add suffix W/30 (for example, T183E W/30).
  • To order the 4-pin Micro-style QD models, add suffix Q1 (for example, T183EQ1). A model with a QD connector requires a mating cable. 2 Use polarized models when shiny objects will be sensed. T18 Series Sensors (AC Voltage) Original Document 116164 Rev. C

18 October 2017

4-pin Micro-style QD Emitters All Other Micro-style QD Models 20-250 V ac No Connection rd/wh rd/bk rd gn 20-250 V ac No Connection Load rd/wh rd rd/bk gn Dimensions Cabled Models QD Models 51.5 mm (2.03") ø 40.0 mm (1.57") Jam Nut (Supplied) 11.5 mm (0.45") M18 x 1 Thread ø 15 mm (0.59") 30.0 mm (1.18") Green LED Power Indicator Yellow LED Output Indicator 66.5 mm (2.62") ø 40.0 mm (1.57") Single-turn Sensitivity (Gain) Control (D and L Models) Specifications Supply Voltage and Current 20 to 250 V ac (50/60 Hz) Average current: 20 mA Peak current: 200 mA at 20 V ac, 500 mA at 120 V ac, 750 mA at 250 V ac Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Configuration SPST solid-state ac switch; Three-wire connections; Choose light operate or dark operate models Light Operate: Output conducts when sensor sees its own (or the emitter’s) modulated light Dark Operate: Output conducts when the sensor sees dark Output Rating 300 mA maximum (continuous) Fixed-field models: derate 5 mA/°C above +50 °C (+122 °F) Inrush Capability 1 amp for 20 milliseconds, non-repetitive OFF-state leakage current: < 100 microamps ON-state saturation voltage: 3 V at 300 mA ac; 2 V at 15 mA ac Output Protection Circuitry Protected against false pulse on power-up Output Response Time Opposed mode models: 16 ms ON, 8 ms OFF Other models: 16 ms ON and OFF NOTE: 100 ms delay on power-up Repeatability Opposed mode models: 2 ms Other models: 4 ms Repeatability and response are independent of signal strength. Adjustments Non-polarized retroreflective and diffuse models (only) have a single-turn rear- panel sensitivity control (turn clockwise to increase gain) Indicators Two LEDs (green and amber) Green on: power to sensor is on Amber on: sensor sees light Amber flashing: excess gain marginal (1 to 1.5×) in light condition Construction Housing: PBT polyester housing Lens: polycarbonate (opposed-mode) or acrylic (other models) Connections 2 m (6.5 ft) integral cable; 9 m (30 ft) integral cable; or 4-pin Micro-style quick- disconnect fitting T18 Series Sensors (AC Voltage) 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 116164 Rev. C

Leakproof design rated NEMA 6P and IEC IP67 per IEC 60529 IP69K per DIN40050 for quick disconnect and cable models when the cables are protected from direct spray Operating Conditions 90% at +50 °C maximum relative humidity (non-condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 Hz to 60 Hz, max., double amplitude 0.06 inch acceleration 10G). Method 213B conditions H&I. Shock: 75G with unit operating; 100G for non-operation Certifications Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to http://www.bannerengineering.com . Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Accessories 4-Pin Micro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQAC-406 1.83 m (6 ft) Straight 42 Typ. ø 14.51/2-20 UNF-28 1 = Red/Black 2 = Red/White 3 = Red 4 = Green MQAC-415 4.57 m (15 ft) MQAC-430 9.14 m (30 ft) MQAC-406RA 1.83 m (6 ft) Right-Angle

32 Typ

28 Typ

ø 14.5 1/2-20 UNF-28 MQAC-415RA 4.57 m (15 ft) MQAC-430RA 9.14 m (30 ft) Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. T18 Series Sensors (AC Voltage) © Banner Engineering Corp. All rights reserved