Date of publication: 2021-05-11 Revision: 3.2 1/10 Seite/page Key Parameters VDRM / VRRM 1600V ITAVM 1770A (TC=85 °C) ITSM 34000A VT0 0,80V rT 0,167mΩ RthJC 17,0K/kW Clamping Force 14…26kN Max. Diameter 75 mm Contact Diameter 50 mm Height 26,5 mm For type designation please refer to actual short form catalog http://www.ifbip.com/catalog Merkmale Features Volle Sperrfähigkeit 50/60Hz über einen weiten Temperaturbereich Full blocking 50/60Hz over a wide range temperature range Hohe DC Sperrstabilität High DC blocking stability Hohe Stoßstrombelastbarkeit High surge current capability Industrie-Standard-Gehäuse Industial standard package Typische Anwendungen Typical Applications Sanftanlasser Soft starter Mittelspannungsumrichter Medium voltage converters Gleichrichter für Antriebsapplikationen Rectifier for drives applications content of customer DMX code DMX code DMX code digit digit quantity serial number 1..7 7 SP material number 8..16 9 datecode (production day) 17..18 2 datecode (production year) 19..20 2 datecode (production month) 21..22 2 vT class (optional) 23..26 4 QR class (optional) 27..30 4 1 2 4 5 www.ifbip.com support@infineon-bip.com
Date of publication: 2021-05-11 Revision: 3.2 2/10 Seite/page Elektrische Eigenschaften / Electrical properties Höchstzulässige Werte / Maximum rated values Periodische Vorwärts- und Rückwärts-Spitzensperrspannung repetitive peak forward off-state and reverse voltages Tvj = -40°C... Tvj max VDRM,VRRM 1600 V Vorwärts-Stossspitzensperrspannung non-repetitive peak forward off-state voltage Tvj = -40°C... Tvj max VDSM 1600 V Rückwärts-Stossspitzensperrspannung non-repetitive peak reverse voltage Tvj = +25°C... Tvj max VRSM 1700 V Durchlassstrom-Grenzeffektivwert maximum RMS on-state current TC = 85°C ITRMS 2780 A Dauergrenzstrom average on-state current TC = 85°C ITAVM 1770 A Dauergrenzstrom average on-state current TC = 55°C, θ = 180°sin, tP = 10ms ITAVM 2410 A Durchlaßstrom-Effektivwert RMS on-state current ITRMS 3790 A Stossstrom-Grenzwert surge current Tvj = 25°C, tP = 10ms Tvj = Tvj max, tP = 10ms ITSM 34000 28000 A A Grenzlastintegral I²t-value Tvj = 25°C, tP = 10ms Tvj = Tvj max, tP = 10ms I²t 5780 3920 10³ A²s 10³ A²s Kritische Stromsteilheit critical rate of rise of on-state current DIN IEC 60747-6 f = 50Hz, iGM = 1A, diG/dt = 1A/µs (diT/dt)cr 250 A/µs Kritische Spannungssteilheit critical rate of rise of off-state voltage Tvj = Tvj max, vD = 0,67 VDRM 5.Kennbuchstabe / 5th letter F (dvD/dt)cr 1000 V/µs Charakteristische Werte / Characteristic values Durchlassspannung on-state voltage Tvj = Tvj max, iT = 3kA vT max. 1,3 V Schleusenspannung threshold voltage Tvj = Tvj max V(TO) max 0,80 V Ersatzwiderstand slope resistance Tvj = Tvj max rT max 0,167 mΩ Durchlasskennlinie 200A ≤ iT ≤ 3500A on-state characteristic Tvj = Tvj max A= 2,497E-01 1,175E-04 1,015E-01 -2,092E-03 Zündstrom gate trigger current Tvj = 25°C, vD = 12V IGT max. 250 mA Zündspannung gate trigger voltage Tvj = 25°C, vD = 12V VGT max. 2 V Nicht zündender Steuerstrom gate non-trigger current Tvj = Tvj max, vD = 12V Tvj = Tvj max, vD = 0,5 VDRM IGD max. max. mA mA Nicht zündende Steuerspannung gate non-trigger voltage Tvj = Tvj max, vD = 0,5 VDRM VGD max. 0,25 V Haltestrom holding current Tvj = 25°C, vD = 12V IH max. 500 mA Einraststrom latching current Tvj = 25°C, vD = 12V, RGK ≥ 10Ω iGM = 1A, diG/dt = 1A/µs, tg = 20µs IL max. 2500 mA Vorwärts- und Rückwärts-Sperrstrom forward off-state and reverse current Tvj = Tvj max vD = VDRM, vR = VRRM iD, iR max. 150 mA Zündverzug gate controlled delay time DIN IEC 60747-6 Tvj = 25°C, iGM = 1A, diG/dt = 1A/µs tgd max. 4 µs prepared by: HR date of publication: 2021-05-11 approved by: MS revision: 3.2
Date of publication: 2021-05-11 Revision: 3.2 3/10 Seite/page Elektrische Eigenschaften / Electrical properties Charakteristische Werte / Characteristic values Freiwerdezeit circuit commutated turn-off time Tvj = Tvj max, iTM = ITAVM vRM = 100 V, vDM = 0,67 VDRM dvD/dt = 20 V/µs, -diT/dt = 10 A/µs 4.Kennbuchstabe / 4th letter O tq typ. 230 µs Thermische Eigenschaften / Thermal properties Innerer Wärmewiderstand thermal resistance, junction to case Kühlfläche / cooling surface beidseitig / two-sided, θ = 180°sin beidseitig / two-sided, DC Anode / anode, θ = 180°sin Anode / anode, DC Kathode / cathode, θ = 180°sin Kathode / cathode, DC RthJC max. max. max. max. max. max. 18,5 17,0 35,7 34,2 36,5 35,0 K /kW K/kW K/kW K/kW K/kW K/kW Übergangs-Wärmewiderstand thermal resistance, case to heatsink Kühlfläche / cooling surface beidseitig / two-sides einseitig / single-sides RthCH max. max. 2,5 5,0 K/kW K/kW Höchstzulässige Sperrschichttemperatur maximum junction temperature Tvj max 135 °C Betriebstemperatur operating temperature Tc op -40…+135 °C Lagertemperatur storage temperature Tstg -40…+150 °C Mechanische Eigenschaften / Mechanical properties Gehäuse, siehe Anlage case, see annex Seite 4 page 4 Si-Element mit Druckkontakt Si-pellet with pressure contact Anpresskraft clamping force F 14…26 kN Steueranschlüsse control terminals Gate (flat) Gate (round, based on AMP 60598) Kathode / cathode A 2,8x0,5 Ø 1,5 A 4,8x0,5 mm mm mm Gewicht weight G typ. 600 g Kriechstrecke creepage distance 20 mm Schwingfestigkeit vibration resistance f = 50 Hz 50 m/s²
Date of publication: 2021-05-11 Revision: 3.2 4/10 Seite/page 1 2 4 5 1: Anode / Anode 2: Kathode / Cathode 4: Gate 5: Hilfskathode/ Auxiliary Cathode
Date of publication: 2021-05-11 Revision: 3.2 5/10 Seite/page Analytische Elemente des transienten Wärmewiderstandes Z thJC für DC Analytical elements of transient thermal impedance Z thJC for DC Kühlung / Cooling Pos. n 1 2 3 4 5 6 7 beidseitig two-sided Rthn [K/kW] 1,5 3 10 1 1,5 0 0 n [s] 13 2 0,17 0,018 0,003 1 1 anodenseitig anode-sided Rthn [K/kW] 15,7 6 10 1 1,5 0 0 n [s] 21 6 0,17 0,018 0,003 1 1 kathodenseitig cathode-sided Rthn [K/kW] 16,5 6 10 1 1,5 0 0 n [s] 21 6 0,17 0,018 0,003 1 1 Analytische Funktion / Analytical function: maxn n=1 thnthJC n e1RZ b a c 0,001 0,01 0,1 1 10 100 Z thJC [K/kW] t [s] Transienter innerer Wärmewiderstand für DC / Transient thermal impedance for DC Z thJC = f(t) a - Anodenseitige Kühlung / Anode-sided cooling b - Beidseitige Kühlung / Two-sided cooling c - Kathodenseitige Kühlung / Cathode-sided cooling
Date of publication: 2021-05-11 Revision: 3.2 6/10 Seite/page Erhöhung des Zth DC bei Sinus und Rechteckströmen mit unterschiedlichen Stromflusswinkeln Θ Rise of Zth DC for sinewave and rectangular current with different current conduction angles Θ ΔZth Θ sin / ΔZth Θ rec Kühlung / Cooling ΔZth Θ sin180° [K/kW] ΔZth Θ rec 180° [K/kW] ΔZth Θ rec 120° [K/kW] ΔZth Θ rec 90° [K/kW] ΔZth Θ rec 60° [K/kW] ΔZth Θ rec 30° [K/kW] beidseitig two-sided 1,504 1,970 3,307 4,277 5,595 7,331 anodenseitig anode-sided 1,505 1,970 3,307 4,278 5,596 7,335 kathodenseitig cathode-sided 1,505 1,970 3,308 4,278 5,596 7,336 Zth Θ sin = Zth DC + Zth Θ sin Zth Θ rec = Zth DC + Zth Θ rec Tvj = Tvj max 500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 0,7 0,8 0,9 1 1,1 1,2 1,3 1,4 1,5 iT [A] VT [V] Grenzdurchlasskennlinie / Limiting on-state characteristic iT = f(vT) Tvj = Tvj max
Date of publication: 2021-05-11 Revision: 3.2 7/10 Seite/page 0,1 100 10 100 1000 10000 vG [V] iG [mA] Tvj max =+135 C Tvj = -40 C Tvj = +25 C a b c Steuercharakteristik vG = f (iG) mit Zündbereichen für VD = 12 V Gate characteristic vG = f (iG) with triggering area for VD = 12 V Höchstzulässige Spitzensteuerverlustleistung / Maximum rated peak gate power dissipation PGM = f (tg) : a - 20W / 10ms b - 40W / 1ms c - 60W / 0,5ms 100 1000 10000 1 10 100 Qr [µAs] -di/dt [A/µs] iTM = 2000A 1000A 500A 200A 100A 50A Sperrverzögerungsladung / Recovered charge Qr = f(di/dt) Tvj= Tvjmax, vR ≤ 0,5 VRRM, VRM = 0,8 VRRM Parameter: Durchlassstrom / On-state current iTM
Date of publication: 2021-05-11 Revision: 3.2 8/10 Seite/page DC sin 180° θ = rec 30° rec 120°rec 90°rec 60° rec 180° 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 0 500 1000 1500 2000 2500 3000 3500 PTAV [W] ITAV [A] Durchlassverlustleistung / On-state power loss PTAV = f(ITAV) Parameter: Stromflusswinkel Θ / Current conduction angle Θ DCrec 180° rec 120° rec 90° rec 60° θ = rec 30° sin 180° 100 120 140 0 500 1000 1500 2000 2500 3000 3500 T C [°C] I TAV [A] Höchstzulässige Gehäusetemperatur / Maximum allowable case temperature TC = f(ITAV) Beidseitige Kühlung / Two-sided cooling Parameter: Stromflusswinkel Θ / Current conduction angle Θ
Date of publication: 2021-05-11 Revision: 3.2 9/10 Seite/page 0-50V 0,33 VRRM 0,67 VRRM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 IT(OV)M [kA] Anzahl Pulse bei 50Hz Sinus Halbwellen Number of pulses for 50Hz sinusoidal half waves Typische Abhängigkeit des Grenzstromes IT(OV)M von der Anzahl für eine Folge von Sinus Halbwellen bei 50Hz. Parameter: Rückwärtsspannung VRM Typical dependency of maximum overload on-state current IT(OV)M as a number of a sequence of sinusoidal half waves at 50Hz. Parameter: peak reverse voltage VRM IT(OV)M = f (pulses, VRM) ; Tvj = Tvjmax
Date of publication: 2021-05-11 Revision: 3.2 10/10 Seite/page Nutzungsbedingungen Die in diesem Produktdatenblatt enthaltenen Daten sind ausschließlich für technisch geschultes Fachpersonal bestim mt. Die Beurteilung der Eignung dieses Produktes für Ihre Anwendung sowie die Beurteilung der Vollständigkeit der bereitgestellten Produktdaten für diese Anwendung obliegt Ihnen bzw. Ihren technischen Abteilungen. In diesem Produktdatenblatt werden dieje nigen Merkmale beschrieben, für die wir eine liefervertragliche Gewährleistung übernehmen. Eine solche Gewährleistung richtet sich ausschließlich nach Maßgabe der im jeweiligen Liefervertrag enthaltenen Bestimmungen. Garantien jeglicher Art werden für das Produkt und dessen Eigenschaften keinesfalls übernommen. Sollten Sie von uns Produktinformationen benötigen, die über den Inhalt dieses Produktdatenblatts hinausgehen und insbesonder e eine spezifische Verwendung und den Einsatz dieses Produktes betreffen , setzen Sie sich bitte mit dem für Sie zuständigen Vertriebsbüro in Verbindung. Für Interessenten halten wir Application Notes bereit. Aufgrund der technischen Anforderungen könnte unser Produkt gesundheits gefährdende Substanzen enthalten. Bei Rückfra gen zu den in diesem Produkt jeweils enthaltenen Substanzen setzen Sie sich bitte ebenfalls mit dem für Sie zuständigen Vertriebsbüro in Verbindung. Sollten Sie beabsichtigen, das Produkt in gesundheits - oder lebensgefährdenden oder lebenserhaltenden Anw endungsbereichen einzusetzen, bitten wir um Mitteilung. Wir weisen darauf hin, dass wir für diese Fälle - die gemeinsame Durchführung eines Risiko- und Qualitätsassessments; - den Abschluss von speziellen Qualitätssicherungsvereinbarungen; - die gemeinsame Einführung von Maßnahmen einer laufenden Produkt beobachtung dringend empfehlen und gegebenenfalls die Belieferung von der Umsetzung solcher Maßnahmen abhängig machen. Soweit erforderlich, bitten wir Sie, entsprechende Hinweise an Ihre Kunden zu geben. Inhaltliche Änderungen dieses Produktdatenblatts bleiben vorbehalten. Terms & Conditions of usage The product data contained in this product data sheet is exclusively intended for technically trained staff. You and your technical departments will have to evaluate the suitability of the product for the intended application and the completeness of the product data with respect to such application. This product data sheet is describing the specifications of this product for which a warranty is granted. Any such warranty is granted exclusively pursuant the terms and conditions of the supply agreement. There will be no guarantee of any kind for the product and its specifications. Should you require product information in excess of the data given in this product data sheet or which concerns the specific application of our product, please contact the sales office, which is responsible for you. For those that are specifically in terested we may provide application notes. Due to technical requirements our p roduct may contain dangerous substances. For information on the types in question please contact the sales office, which is responsible for you. Should you intend to use the Product in health or live endangering or life support applications, please notify. Please note, that for any such applications we urgently recommend - to perform joint Risk and Quality Assessments; - the conclusion of Quality Agreements; - to establish joint measures of an ongoing product survey, and that we may make delivery depended on the realization of any such measures. If and to the extent necessary, please forward equivalent notices to your customers. Changes of this product data sheet are reserved.