Thermal (T- and TA-Line) T12-111https://www.schurter.com /PG17_20 Circuit Breakers Circuit Breaker for Equipment thermal, Flange type, Reset type, Quick connect terminals See below: Approvals and Compliances
Description
- Flange type - Thermal circuit breaker - 1-pole - Reset type - Quick connect terminals 6.3 x 0.8 mm Unique Selling Proposition - Compact design - Positively trip-free release - Available with cover - Different mounting possibilities
Applications
- Power supplies - Uninterruptible power supply - Power tools - Household appliances Weblinks pdf data sheet, html datasheet, General Product Information, Distributor- Stock-Check, Detailed request for product, Product News Technical Data Rated Voltage AC AC 240 VAC Rated Voltage DC 28 VDC Rated current range AC 0.05 - 15/16 A , see approbations Conditional short circuit ca- pacity IEC: Inc, PC1, AC 240 V: 1 kA Short circuit capacity Icn at In < 7 A/240 VAC : 8 x In at In ≥ 7 A/240 VAC : 200 A AC/DC 28 V : 400 A Degree of Protection from front side IP40 acc. to IEC 60529 Dielectric Strength 50 Hz: > 1.5 kV Impulse 1.2/50 μs: > 2.5 kV Insulation Resistance 500 VDC > 100 MΩ Endurance typical 2 x Ir: 5000 switching cycles Endurance minimum Reset type AC : 2 x Ir , cos φ 0.6 : DC : 2 x Ir , L/R = 2 - 3 ms : 50 switching cycles Overload IEC: min. 40 trips @ 6 x Ir, cos φ 0.6 ␣ UL / CSA: min. 50 trips @ 1.5 x Ir, cos φ 0.75 Allowable Operation Temp. -5 °C to 60 °C Vibration Resistance ± 1.5 mm @ 10 - 60 Hz acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc Shock Resistance 100 G / 6 ms acc. to IEC 60068-2-27, test Ea Tripping Type Thermal Actuation Type Reset type Weight ca. 10 g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree- ments by SCHURTER.
Thermal (T- and TA-Line)T12-111 https://www.schurter.com /PG17_20 Circuit Breakers Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: T12 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 99673 UL Approvals UL UL File Number: E71572 CCC Approvals CCC CCC Certificate Number: 2012010307564275 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60934 Circuit-breakers for equipment (CBE) Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to CSA C22.2 No. 235 Supplementary Protectors Designed according to GB 17701 Circuit-breaker for equipment Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Thermal (T- and TA-Line) T12-111https://www.schurter.com /PG17_20 Circuit Breakers Dimension [mm] T12-111 11.5 Ø11.5 1 2 24.6 48.5 +0.5 –0.22 31–0 .2 13.5 10.7 Ø 5.7 50.0 Ø 5.7 6.3 17 –0 .2 T12-111SN 11.5 Ø 11.5 1 2 57.5 13.5 10.7 Ø 5.7 48.5 +0.5 –0.2 2.5 24.6 31–0 .2 Ø 4.5 8.6 564
Thermal (T- and TA-Line)T12-111 https://www.schurter.com /PG17_20 Circuit Breakers 17.5 17.5 4.5 Installation from rear 17.5 17.5 +1.0 +0.2 4.5 Installation from front Diagrams T12-... T12-...N T12-...S T12-...SN 1 4 Approval Main circuit Auxiliary circuit Rated current Rated Voltage AC Rated Voltage DC Rated current Rated Voltage AC Rated Voltage DC UL 1077 CSA C22.2 No. 235 0.05...15 A 240 V 28 V 2 A 3 A 120 V 28 V IEC 60934 0.05...16 A 240 V 28 V 1 A 240 V 28 V GB 17701 0.05...16 A 240 V 28 V 1 A 240 V 28 V
Thermal (T- and TA-Line) T12-111https://www.schurter.com /PG17_20 Circuit Breakers Typical internal resistance Rated Current [A] Internal Resistance [Ω] 0.05 225.000 0.50 3.300 1.00 0.880 2.00 0.267 3.00 0.128 4.00 0.073 5.00 0.040 6.00 0.031 7.00 0.018 8.00 0.018 9.00 0.010 10.00 0.0087 11.00 0.0087 12.00 0.0087 13.00 0.0087 14.00 0.0070 15.00 0.0070 16.00 0.0055 Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated cur- rent for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient Temperature [°C] Correction factor -5 0.87 0 0.90 10 0.95 23 1.00 30 1.05 40 1.12 50 1.20 60 1.30 Example: Rated current = 5 A, Environmental temperature = 50 °C, --> Correction factor = 1.2, Resulting current = 6.0 A
Thermal (T- and TA-Line)T12-111 https://www.schurter.com /PG17_20 Circuit Breakers Time-Current-CurvesTime in Seconds 10'000 2´000 1´000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 10854321,32 < 7,0 A > 7,0 A Multiple of Rated Current In Reference Temperature +23° Config. Code The characters are placeholders for the correspondingly keys of selections from the key tables. Mounting Configuration key Screwflange mounting 1 Actuation Type Configuration key Reset type 1 T12 Terminal Configuration key Quick connect terminal 6.3x0.8mm 1 T12 Auxiliary contact Configuration key Auxiliary contact S T12 Shunt terminal Configuration key Shunt terminal N T12 Setting indication Configuration key Setting indication R T12 Rated current Configuration key 0.05 A 0.05 0.1 A 0.1 0.15 A 0.15 0.2 A 0.2 0.3 A 0.3 0.4 A 0.4 0.5 A 0.5 0.6 A 0.6 0.7 A 0.7 0.8 A 0.8 0.9 A 0.9 1.0 1 1.1 A 1.1 1.2 A 1.2 1.3 A 1.3 1.4 A 1.4 Other rated currents on request
Thermal (T- and TA-Line) T12-111https://www.schurter.com /PG17_20 Circuit Breakers Rated current Configuration key 1.5 A 1.5 1.6 A 1.6 1.7 A 1.7 1.8 A 1.8 1.9 A 1.9
2.0 A 2
2.1 A 2.1 2.3 A 2.3 2.5 A 2.5 2.8 A 2.8
3.0 A 3
3.3 A 3.3 3.5 A 3.5
4.0 A 4
4.5 A 4.5
5.0 A 5
Other rated currents on request Rated current Configuration key 5.5 A 5.5 6.0 6 6.5 A 6.5
7.0 A 7
7.5 A 7.5
8.0 A 8
8.5 A 8.5
9.0 A 9
9.5 A 9.5
10.0 A 10
11.0 A 11
12.0 A 12
13.0 A 13
14.0 A 14
15.0 A 15
16.0 A 16
Other rated currents on request Variants Rated Current [A] Construction variants Config. Code Order Number Auxiliary contact Shunt terminal Setting indication 1.5 T12-111-1.5 4410.0038 2 T12-111-2 4410.0034 3 T12-111-3 4410.0135 10 T12-111-10 4410.0163 15 T12-111-15 4410.0777 16 l T12-111S-16 4410.0385 Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock- Check-SCHURTER Packaging Unit 20 Pcs Accessories The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 03.07.2019