SVS16-PB-08-C13-P01 E-T-A | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
www.e-t-a.de Power distribution system SVS16-PB 1712
Description
Technical data (Tamb = 25 °C, UB = DC 24 V) SVS16-PB The new power distribution and remote output system type SVS16- PB-xx offers selective overcurrent protection, power distribution of load circuits and switching, protection and diagnosis of digital out- puts up to 10 A. An integral consistent communication of operating and fault conditions as well as switching and resetting of individual circuits on the DC 24 V level via PROFIBUS-DP make the SVS16-PB an intelligent sub-system on the control level. The SVS16-PB for direct rail mounting accommodates 8 (SVS16-PB-08-Cx3-P0x) or 16 (SVS16-PB-16-Cx3-P0x) electronic circuit protectors up to 10 A of type ESX10-(S)125 (with reset input) or ESX10-(S)115 (with control input). They ensure selective overcurrent protection of sensors and actuators, de-centralised peripheral sub-assemblies and their supply lines. Alternatively the slots of the SVS16-PB allow the use of the solid state power controllers type E-1048-S7xx. Their well-proven features include activation, monitoring and diagnosis of hydraulic or pneumatic solenoids, magnetic valves, signal lamps etc. in a range of 0.5 A to 5 A with regard to short circuit, overload or wire breakage. PROFIBUS-DP makes all benefits of this approved system available for the protection of DC 24 V circuits. The SVS16-PB has a fully-fledged PROFIBUS-DP interface supporting all specified Baud rates up to max. 12 MBaud. The SVS16 reduces wiring times and increases diagnostic capabilities and system availability in process control, chemical, petrochemical, pharmaceutical and foodstuffs industry, in steel production and car manufacturing. Features and Benefits l Integral complete DC 24 V system for overcurrent protection, power distribution and remote input and output l Systematic integration of protection and distribution functions l Power distribution and selective protection of DC 24 V load circuits all in one l For electronic circuit protectors ESX10-(S)115/-(S)125 bis 10 A l For solid state remote power controller E-1048-S7xx up to 5 A l Fully-fledged PROFIBUS-DP interface l Integral diagnostic functions for load circuits (overcurrent, wire breakage etc.) l Profitability through considerably reduced wiring time l Reduction of planning, design and installation time l Ease of maintenance, diagnosis and system extension Application: Modular power distribution system for short circuit current limited DC 24 V applications. Line entry load module (X21) Rated voltage DC 24 V (18 ... 32 V) Total current max. 40 A PE = (X21) PE, connected to DC 24 V (-) integral loop-through Terminal design 5-pole spring-loaded terminals, (1+/2+/1-/2-/PE) Cable cross section max. 10 mm Connection of line entry of BUS module (X31) is compulsory Rated voltage: Current consumption Terminals: max. 250 mA integral loop-through, 2 x 2-pole PT terminals, (1+/2+) (1-/2-) 2 x 2-pole PT terminals, (1+/2+) (1-/2-) cable cross section max. 1.5 mm F-slots Number of slots for circuit breakers, prepared for circuit protector types ESX10-(S)115, ESX10-(S)125, E-1048-S7xx Load outputs per way / slot Rated voltage: Current: Terminals: DC 24 V (18 ... 32 V) max. 10A per terminal block / slot 1) (L+) protected load output (+) (L-) negative return load (-) (PE) three-level screwless spring-loaded terminals Cable cross section max. 2.5 mm BUS terminal (X50) PROFIBUS–DP: D-Sub, 9-pole, connector (X50) 1) When mounted side-by-side, the circuit protectors ESX10 and the SSRPCs E-1048 rated 10A the devices can only carry 80% of their rated load continuously. Suitable for the following types: Electronic circuit protector ESX10-(S)115.. (with con- trol input and status output) Electronic circuit protector ESX10-(S)125.. (with reset input and status output) Solid state remote power controller E-1048-S7xx.. (with control input and status output) Approvals l CE
www.e-t-a.de Power distribution system SVS16-PB 1712 Technical data (Tamb = 25 °C, UB = DC – 24 V) Termination For supply lines and load outputs C13 print spring-loaded terminals (standard) line entry load module DC 24 V on terminal block (X21) 5-pole spring-loaded terminals, (1+/2+/1-/2-/PE) max. cable cross section flexible with wire end ferrule w/wo plastic sleeve 0.5 mm – 10 mm 2 stripping length 12 mm line entry BUS module DC 24 V on terminal block (X31) 2 x 2-pole PT terminals, (1+/2+) (1-/2-) flexible with wire end ferrule (with plastic sleeve) 0.25 – 1.5 mm2 flexible with wire end ferrule (without plastic sleeve) 0.25 – 2.5 mm2 stripping length 8 mm Load outputs on terminal block 8x (16x) double level screwless spring-loaded terminals max. cable cross section flexible with wire end ferrule (with plastic sleeve) 0.25 – 1.5 mm2 cable cross section AWG 0.20 – 2.5 mm2 stripping length 7.5 mm Please note Configuration parameters Pxx "PROFIBUS-DP" PROFIBUS-DP Bus System Caution l The max. total current of 40A per way must not be exceeded l It is only intended for use with safety extra-low voltage (=24V DC). l Connection to a higher or not reliably disconnected voltage can cause hazardous conditions or damages. l The user has to ensure that the cable cross section of the load circuit in question complies with the current rating of the used load or circuit protector. l The technical data of the used circuit protectors have to be observed. l In addition special precautions must be taken in the system or machine (e.g. use of a safety PLC) which reliably prevent an automatic re-start of parts of the system (cf. Machinery Directive 2006/42/EG and EN 60204-1, Safety of Machinery). In the event of a failure (short circuit/overload) the load circuit will be disconnected by the circuit protector. l The power distribution system must only be installed by qualified personnel. l Only after expert installation must the device be supplied with power. l After tripping of the circuit protector and before reset, the cause of the failure (short circuit or overload) must be remedied.. l The national standards (e.g. for Germany DIN VDE 0100) have to be observed for installation and selection of feed and return cables. l 0V ptential load and control voltage connected l For convenient adjustment and configuration by means of projecting software a master data file with the file name ETA_0C9E.gsd will be made available for downloading on the E-T-A homepage. Please observe the user manual for type SVS16-PB-xx. The output behaviour in the event of a PROFIBUS error (master failure, disruption of bus line etc.) can vary depending on the type configuration of the SVS16: SVS16-PB-XX-XX-P01 A bus error will not affect the condition of the connected loads. The output byte(s) assigned to the slots remain unchanged. SVS16-PB-XX-XX-P02 A bus error will affect the condition of the connected loads. The output byte(s) assigned to the slots will be set to 0, i.e. the connected loads will be disconnected. PROFIBUS-DP is a master-slave bus system to which up to 126 participants can be connected. Max. 32 participants can be operated at one bus segment. More detailed information on the bus system, planning, mounting and operation of a system can be found in the official documents of the PROFIBUS user organisation (PNO). The link www.profibus.com/downloads/ will lead you to the following documents: l PROFIBUS (technical directive) l PROFIBUS (planning directive) l PROFIBUS (installation directive) l PROFIBUS (operation directive) Caution: Electrostatically sensitive sub-assemblies can be destroyed by voltages far below the human perception threshold. These voltages already occur if you touch a component or electrical terminals of a sub-assembly without being electrostatically discharged. The damage of a sub- assembly caused by an overvoltage is often not immediately recognised, but will be noticed only after a longer operating time. Type SVS16 Power distribution system for ESX10-(S)115, ESX10-(S)125, E-1048-S7xx l Short-circuit limited DC 24 V applications l Max. cont. load 40 A l Max. cont. load per load output: 10 A l BUS connection Version: Bus system PB PROFIBUS–DP (connection D-Sub, 9-pole, connector) Max. number of circuit protectors on the distribution system 08 8 circuit protectors [F1...F8] 16 16 circuit protectors [F1...F16] Fitting version C13 standard: completely fitted with screwless spring-loaded terminals Configuration parameters / behaviour at PROFIBUS error P01 output byte(s) unchanged P02 output byte(s) resetting SVS16 - PB - 08 - C13 - P01 ordering example Order numbering code
www.e-t-a.de Power distribution system SVS16-PB 1712 Power distribution system SVS16-PB General data Application: Mounting method symmetrical rail to EN 60715 - 35 x 7.5 Temperature range 0 °C to 50 °C (without condensation) Storage temperature -20...+70° Housing material plastic Protection class terminals IP20 DIN 40050 pcb IP00 DIN 40050 Insulation voltage DC 250 V (pcb) Dimensions see dimensional drawing (tolerances to DIN ISO 286 part 1 IT13) Mass SVS16-PB-08-C13-Pxx approx. 515g SVS16-PB-16-C13-Pxx approx. 810g EMC l EN 61000-6-2: 2005 Electromagnetic compatibility (EMC) part 6-2: Basic standards - noise immunity for industrial areas l EN 61000-6-4: 2007+A1: 2011 Electromagnetic compatibility (EMC) part 6-4: Basic standards - noise immunity for industrial areas Mounting position Accessories blade terminals DIN 46244-A 6.3-0.8 7010.3 2.36 12.3 terminals 13+14 bridged Signalbrücke Signal loop Germanywww.e-t-a.de Signalbrücke Signal loop xxxx SB-S11-P1-01-1-1A Jumper SB-S11-P1-01-1-1A .484 .406 2.76 top view AC 240 V / DC 65 V, 1 A
www.e-t-a.de Power distribution system SVS16-PB 1712 Schematic diagram SVS16-PB-08-… Schematic diagram SVS16-PB-16-… bus pcb PROFIBUS-DP Slave Error Resetx1x10 Bus-Address Bus- connection PROFIBUS 9pole D-SUB + bus pcb X31 DC24VPE PEPE PE ---- ++++ X8X7X2X1 load pcb F2 F7 F8 + 5 V bus pcb X21 1+ 2+ 1- 2- PE DC 24 V / max. 40 A Load IN+/PE SO Load IN+/PE SO Load IN+/PE SO Line GND SC Line GND SC Line GND SC Line GND SC Load IN+/PE SO bus pcb communication bus pcb communication bus pcb communication bus pcb communication 1+ 2+ 1- 2- - bus pcb GERMANY X50 communication Bus ETA SVS16-PB-08 bus pcb PROFIBUS-DP Slave Error Resetx1x10 Bus-Address Bus- connection PROFIBUS 9pole D-SUB + bus pcb X31 DC24VPE PEPE PE ---- ++++ X16X15X2X1 load pcb F2 F15F 16 + 5 V bus pcb X21 1+ 2+ 1- 2- PE DC 24 V / max. 40 A Load IN+/ PE SO Load IN+/ PE SO Load IN+/ PE SO Line GND SC Line GND SC Line GND SC Line GND SC Load IN+/ PE SO bus pcb communication bus pcb communication bus pcb communication bus pcb communication 1+ 2+ 1- 2- - bus pcb GERMANY X50 communication Bus ETA SVS16-PB-16
www.e-t-a.de Power distribution system SVS16-PB 1712 Power distribution system SVS16-PB Dimensions SVS16-PB-08-C13-Pxx Dimensions SVS16-PB-16-C13-Pxx F1 F2 F3 F4 F5 F6 F7 F8 DC24V/40A X1 X2 X3 X4 X5 X6 X7 X8 X1 X2 X3 X4 X5 X6 X7 X8 1+ 2+ 1- 2- PE X50 X21 P E P E Bus-Adr. x10 x1 Reset Fehler Bus X31 DC24V symmetrical rail EN 50022-35 x 7,5 (not part of the product) bus connection 9-pole power supply bus push-in terminal 1,5 mm2, 2x2-pole, DC 24 V load outputs: (+/-/PE) screwless terminals, three-level 1,5 mm max. 10 A terminals power supply screwless terminal 10,0 mm2, 5 pole max. 40 A jumper all-insulated 127.8 56.4 185 Bus-Adr. x10 x1 Reset Fehler Bus F1 F2 F3 F4 F5 F6 F7 F8 DC24V/40A X1 X2 X3 X4 X5 X6 X7 X8 X1 X2 X3 X4 X5 X6 X7 X8 1+ 2+ 1- 2- PE X50 X21 PE X9 X10 X11 X12 X13 X14 X15X16 X9 X10 X11 X12 X13 X14 X15 X16 F9 F10F 11 F12F 13 F14F 15 F16 PE PE PE X31 DC24V 285 127.8 power supply bus push-in terminal 1,5 mm 2, 2x2-pole, DC 24 V load outputs: (+/-/PE) screwless terminals, three-level 1,5 mm max. 10 A terminals power supply screwless terminal 10,0 mm 2, 5 pole max. 40 A jumper all-insulated 56.4 symmetrical rail EN 50022-35 x 7,5 (not part of the product) bus connection 9-pole
www.e-t-a.de Power distribution system SVS16-PB 1712 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications with- out notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted.